We present the design and performance of the XRISM Soft X-Ray Spectrometer Resolve, successfully launched on a JAXA H-IIA rocket September 7, 2023. The instrument uses a 36-pixel array of microcalorimeters at the focus of a grazing-incidence x-ray mirror. The instrument has achieved an energy resolution of 4.5 eV (FWHM) at 6. The overall cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications that the cryogen lifetime will exceed 4 years. X-rays are focused onto the array with a high-throughput grazing incidence X-ray Mirror Assembly with over 200 nested two-stage X-ray reflectors. A series of onboard X-ray calibrations sources allow simultaneous energy scale calibration lines simultaneously while observing celestial sources. The inflight performance of Resolve will be described along with a summary of the scientific capabilities.
The initial on-orbit checkout of the soft X-ray spectroscopic system on board the XRISM satellite is summarized. The satellite was launched on September 6, 2023 (UT) and has been undergoing initial checkout since then. Immediately after the launch, the cryocoolers were turned on and their operation was established. The first cycle of the adiabatic demagnetization refrigerator was performed on Oct. 9th, 2023, to transition the sensor to steady-state operational temperature conditions. Subsequently, the filter wheel, which supports energy calibration, was started up. The energy scale is highly sensitive to the temperature environment around the sensor and its analog electronics. The gain correction was established by referring to the calibration X-ray line. For an optimization of the cooler frequencies, we took data including the noise spectra by scanning the cooler frequencies, and selected a good frequency pair in the on-orbit environment. At the last stage of the checkout, the gate valve, which protects the inside of the Dewar from outside air pressure at launch, was attempted to be opened to bring the system to a state where it is ready for regular operations but was failed.
The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides non-dispersive spectroscopy with 5 eV spectral resolution in the soft x-ray waveband. Resolve has a requirement to provide absolute energy-scale calibration of ± 2 eV from 0.3–12 keV. In this manuscript we describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared to Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of ‘mid-res’ secondary events, which have suppressed gain due to proximity to a preceding x-ray event (18-70 ms) on the same pixel. We provide an assessment of how well these pre-launch gain scales correct on-orbit data and discuss approaches for updating the gain curves. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit (X-IFU) on Athena and the microcalorimeter spectrometer proposed for the Line Emission Mapper (LEM), have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.
The X-Ray Imaging and Spectroscopy Mission (XRISM) project at JAXA officially started in 2018. Following the development of onboard components, the proto-flight test was conducted from 2021 to 2023 at JAXA Tsukuba Space Center. The spacecraft was launched from JAXA Tanegashima Space Center on September 7, 2023 (JST), and onboard components, including the science instruments, were activated during the in-orbit commissioning phase. Following the previous report in 2020, we report the spacecraft ground tests, the launch operation, in-orbit operations, and the status and plan of initial and subsequent guest observations.
Resolve is the instrument that utilizes an X-ray micro-calorimeter array onboard the XRISM (X-Ray Imaging and Spectroscopy Mission), which was launched on September 6 (UT), 2023. It fully met the spectral performance requirement (7 eV at 6 keV) both on the ground and in orbit and was confirmed to have the same performance as the SXS onboard the ASTRO-H (Hitomi) satellite. The detectors are operated at a low temperature of 50 mK to achieve the required energy resolution with the cooling system to satisfy the lifetime requirement of over 3 years. The cooling system is equipped with a 3-stage ADR and superfluid liquid He (LHe) as the heat sink for the ADR. The Joule-Thomson cooler unit and 2-stage Stirling cooler units are adopted to reduce heat load to the LHe. In the pre-launch operations, we carried out the low-temperature LHe top-off operation. The resultant amount of liquid He was over 35 L at the launch, which is sufficient to meet the lifetime requirement. During the post-launch operation, the LHe vent valve was opened five minutes after launch during the rocket acceleration, and the cryocoolers started in several revolutions as planned which established stable cooling of the dewar.
The resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput x-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H soft x-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in 2022-04 and is under the spacecraft system testing as of writing. The XMA was tested and calibrated separately. Its angular resolution is 1.27′ and the effective area of the mirror itself is 570 cm2 at 1 keV and 424 cm2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.
The Resolve instrument onboard the x-ray imaging and spectroscopy mission (XRISM) hosts an x-ray microcalorimeter that consists of 36 pixels in an array operated at 50 mK. It is currently under development and will be launched in 2022. x-ray microcalorimeters are known for their high spectral resolution, but they also excel in timing resolution for the necessity of cross-correlating event signals with templates in the time domain for accurate energy derivation. Primary and redundant modulated x-ray sources (MXS) are installed in Resolve for the purpose of correcting changes in the energy scale of the microcalorimeters while minimizing additional background; each source is switched on for intervals of O (1 ms) with a duty cycle of ∼1 %. The MXS can also be utilized for calibrating relative timing as a function of pixel, event grade, and energy. We had a week-long run in 2022 June using the flight model hardware during the spacecraft level test with several different settings. We describe the method and the result of the relative timing calibration using this dataset.
This paper describes the design progress of the X ray Integral Field Unit Focal Plane Assembly (X-IFU FPA) for the Athena X-ray observatory. Test results obtained from the Development Model (DM) program are compared to existing numerical models. From these comparisons input to the next FPA Engineering Model (EM) is derived. Measurements have been done to assess the magnetic shielding performance and key thermal properties are verified. A dedicated configuration is used to verify the changes in mechanical dynamic behavior between ambient temperature and after cool-down to assess micro-vibration susceptibility. We conclude with a summary and outlook for the FPA-EM design.
The X-Ray Imaging and Spectroscopy Mission (XRISM) is the successor to the 2016 Hitomi mission that ended prematurely. Like Hitomi, the primary science goals are to examine astrophysical problems with precise highresolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. XRISM carries a 6 x 6 pixelized X-ray micro-calorimeter on the focal plane of an X-ray mirror assembly and a co-aligned X-ray CCD camera that covers the same energy band over a large field of view. XRISM utilizes Hitomi heritage, but all designs were reviewed. The attitude and orbit control system were improved in hardware and software. The number of star sensors were increased from two to three to improve coverage and robustness in onboard attitude determination and to obtain a wider field of view sun sensor. The fault detection, isolation, and reconfiguration (FDIR) system was carefully examined and reconfigured. Together with a planned increase of ground support stations, the survivability of the spacecraft is significantly improved.
The ASTRO-H mission was designed and developed through an international collaboration of JAXA, NASA, ESA, and the CSA. It was successfully launched on February 17, 2016, and then named Hitomi. During the in-orbit verification phase, the on-board observational instruments functioned as expected. The intricate coolant and refrigeration systems for soft X-ray spectrometer (SXS, a quantum micro-calorimeter) and soft X-ray imager (SXI, an X-ray CCD) also functioned as expected. However, on March 26, 2016, operations were prematurely terminated by a series of abnormal events and mishaps triggered by the attitude control system. These errors led to a fatal event: the loss of the solar panels on the Hitomi mission. The X-ray Astronomy Recovery Mission (or, XARM) is proposed to regain the key scientific advances anticipated by the international collaboration behind Hitomi. XARM will recover this science in the shortest time possible by focusing on one of the main science goals of Hitomi,“Resolving astrophysical problems by precise high-resolution X-ray spectroscopy”.1 This decision was reached after evaluating the performance of the instruments aboard Hitomi and the mission’s initial scientific results, and considering the landscape of planned international X-ray astrophysics missions in 2020’s and 2030’s. Hitomi opened the door to high-resolution spectroscopy in the X-ray universe. It revealed a number of discrepancies between new observational results and prior theoretical predictions. Yet, the resolution pioneered by Hitomi is also the key to answering these and other fundamental questions. The high spectral resolution realized by XARM will not offer mere refinements; rather, it will enable qualitative leaps in astrophysics and plasma physics. XARM has therefore been given a broad scientific charge: “Revealing material circulation and energy transfer in cosmic plasmas and elucidating evolution of cosmic structures and objects”. To fulfill this charge, four categories of science objectives that were defined for Hitomi will also be pursued by XARM; these include (1) Structure formation of the Universe and evolution of clusters of galaxies; (2) Circulation history of baryonic matters in the Universe; (3) Transport and circulation of energy in the Universe; (4) New science with unprecedented high resolution X-ray spectroscopy. In order to achieve these scientific objectives, XARM will carry a 6 × 6 pixelized X-ray micro-calorimeter on the focal plane of an X-ray mirror assembly, and an aligned X-ray CCD camera covering the same energy band and a wider field of view. This paper introduces the science objectives, mission concept, and observing plan of XARM.
The soft x-ray spectrometer was designed to operate onboard the Japanese Hitomi (ASTRO-H) satellite. In the beam of this instrument, there was a filter wheel containing x-ray filters and active calibration sources. This paper describes this filter wheel. We show the purpose of the filters and the preflight calibrations performed. In addition, we present the calibration source design and measured performance. Finally, we conclude with prospects for future missions.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.