Electrical tape is found as one type of important trace evidence in crime scene. For example, it is very frequently used to insulate wires in explosive devices in many criminal cases. The fingerprints of the suspects were often left on the adhesive side of the tapes, which can provide very useful clues for the investigation and make it possible for individual identification. The most commonly used method to detect and visualize those latent fingerprints is to peel off each layer of the tapes first and then adopt the chemical methods to develop the fingerprints on the tapes. However, the peeling-off and chemical development process would degrade and contaminate the fingerprints and thus adversely affect the accuracy of identification. Optical coherence tomography (OCT) is a novel forensic imaging modality based on lowcoherence interferometry, which has the advantages of non-destruction, micrometer-level high resolution and crosssectional imaging. In this study, a fiber-based spectral-domain OCT (SD-OCT) system with ~6μm resolution was employed to obtain the image of fingerprint sandwiched between two opaque electrical tapes without any pre-processing procedure like peeling-off. Three-dimensional (3D) OCT reconstruction was performed and the subsurface image was produced to visualize the latent fingerprints. The results demonstrate that OCT is a promising tool for recovering the latent fingerprints hidden beneath opaque electrical tape non-destructively and rapidly.
In most deaths caused by explosions, the fragment of explosive remained on the victim's body can provide valuable clues to forensic investigation. However, the examination of the skin and appendages at the scene of explosion, which may reveal clue to the identity of an individual, has not been extensively studied. Compared with visual appearance of the epidermis surface that affected by various wounds, skin adnexa embedded in the dermis has a more stable morphology as an inner biometric. Hair follicles are formed when a fetus is 5 months old and distributed fairly evenly throughout the body, with the exception of hairless palms and soles. Therefore, we focus on the distribution of hair follicles in order to infer information of age, gender, and race/ethnicity. Optical coherence tomography (OCT) is a novel forensic imaging method, which achieves non-destructive, high-resolution and most importantly cross-sectional imaging. In this study, we design and develop a custom-built spectral-domain three-dimensional (3D) OCT system with a portable handheld probe to detect and reconstruct the hair follicles in the facial skin. We test our system on the forehead and preauricular skin of 2 adult volunteers and demonstrate the high quality visualization of hair follicles beneath the epidermis. The diameter, orientation, density and shape of hair follicles can be extracted from the 3D volume data. The preliminary analysis suggests that these parameters vary from different part of body and have individual difference. Eventually, we believe 3D OCT is promising tool for the examination of hair follicles for forensic purpose.
Vehicle paint chip is a common evidence that plays a significant role in many criminal cases. This paper introduced a novel imaging technology - optical coherence tomography (OCT), which can realize non-invasive, rapid, high-resolution and cross-sectional imaging for the identification of vehicle paint chips. In this paper, a 1310nm swept-source OCT system was adopted to implement the paint imaging. The results show that, compared with conventional spectroscopy and SEM methods, OCT technology can directly obtain the tomographic images of the paints without slicing. In addition, the optical attenuation properties were analyzed to provide a new feature for separating different paint samples. The OCT technology and traditional methods can be combined to further narrow the scope of investigation, providing a comprehensive means to determine or rule out the suspect vehicles.
We present an endoscopic probe for optical coherence tomography (OCT) equipped with a miniaturized hollow ultrasonic motor that rotates the objective lens and provides an internal channel for the fiber to pass through, enabling 360 deg unobstructed circumferential scanning. This probe has an outer diameter of 1.5 mm, which is ultra-small for motorized probes with an unobstructed view in distal scanning endoscopic OCT. Instead of a mirror or prism, a customized aspheric right-angle lens is utilized, leading to an enlargement of the numerical aperture and thus high transverse resolution. Spectral-domain OCT imaging of bio-tissue and a phantom are demonstrated with resolution of 7.5 μm(axial)×6.6 μm(lateral) and sensitivity of 96 dB.
The spindle plays a crucial role in normal chromosome alignment and segregation during meiosis and mitosis. Studying spindles in living cells noninvasively is of great value in assisted reproduction technology (ART). Here, we present a novel spindle imaging methodology, full-field optical coherence tomography (FF-OCT). Without any dye labeling and fixation, we demonstrate the first successful application of FF-OCT to noninvasive three-dimensional (3-D) live imaging of the meiotic spindles within the mouse living oocytes at metaphase II as well as the mitotic spindles in the living zygotes at metaphase and telophase. By post-processing of the 3-D dataset obtained with FF-OCT, the important morphological and spatial parameters of the spindles, such as short and long axes, spatial localization, and the angle of meiotic spindle deviation from the first polar body in the oocyte were precisely measured with the spatial resolution of 0.7 μm. Our results reveal the potential of FF-OCT as an imaging tool capable of noninvasive 3-D live morphological analysis for spindles, which might be useful to ART related procedures and many other spindle related studies.
This paper proposes a novel rotary endoscopic probe for spectral-domain optical coherence tomography (SD-OCT). The probe with a large N.A. objective lens is driven by an ultra-small hollow rectangular ultrasonic motor for circular scanning. Compared to the conventional driven techniques, the hollow ultrasonic motor enables the fiber to pass through its inside. Therefore the fiber, the objective lens and the motor are all at the same side. This enables 360 degree unobstructed imaging without any shadow resulted from power wire as in the conventional motor-driven endoscopic OCT. Moreover, it shortens the length of the rigid tip and enhances the flexibility of the probe. Meanwhile, the ultrasonic motor is robust, simple, quiet and of high torque, very suitable for OCT endoscopic probe. The side length of the motor is 0.7 mm with 5mm in length. The outer diameter of the probe is 1.5mm. A significant improvement in the lateral resolution is demonstrated due to the novel design of the objective lens. A right-angle lens is utilized instead of the traditional right-angle prism as the last optics close to the sample, leading to a reduction of the working distance and an enlargement of the N.A. of the objective lens. It is demonstrated that the endoscopic SD-OCT system achieves an axial resolution of ~7μm, a lateral resolution of ~6μm and a SNR of ~96dB.
The morphogenetic relationship between early patterning and polarity formation is of fundamental interest and remains a controversial issue in preimplantation embryonic development. We use a label-free three-dimensional (3-D) imaging technique of full-field optical coherence tomography (FF-OCT) successfully for the first time to study the dynamics of developmental processes in mouse preimplantation lives. Label-free 3-D subcellular time-lapse images are demonstrated to investigate 3-D spatial relationship between the second polar body (2PB) and the first cleavage plane. By using FF-OCT together with quantitative study, we show that only 25% of the predicted first cleavage planes, defined by the apposing plane of two pronuclei, pass through the 2PB. Also only 27% of the real cleavage planes pass through the 2PB. These results suggest that the 2PB is not a convincing spatial cue for the event of the first cleavage. Our studies demonstrate the feasibility of FF-OCT in providing new insights and potential breakthroughs to the controversial issues of early patterning and polarity in mammalian developmental biology.
Early patterning and polarity is of fundamental interest in preimplantation embryonic development. Label-free subcellular 3D live imaging is very helpful to its related studies. We have developed a novel system of full-field optical coherence tomography (FF-OCT) for noninvasive 3D subcellular live imaging of preimplantation mouse embryos with no need of dye labeling. 3D digitized embryos can be obtained by image processing. Label-free 3D live imaging is demonstrated for the mouse embryos at various typical preimplantation stages with a spatial resolution of 0.7 µm and imaging rate of 24 fps. Factors that relate to early patterning and polarity, such as pronuclei in zygote, shapes of zona pellucida, location of second polar body, cleavage planes, and the blastocyst axis, can be quantitatively measured. The angle between the two second cleavage planes is accurately measured to be 87 deg. It is shown that FF-OCT provides a potential breakthrough for early patterning, polarity formation, and many other preimplantation-related studies in mammalian developmental biology.
Imaging apparatus inevitably impose undesirable noises onto acquired images during real imaging process. Usually these noises are too faint to cause unpleasing visual effects, however, they degrade image fidelity and significantly lower the compression ratio of lossless coding. More baffling, in this case, there leaves little room for traditional noise filtering methods to work. This paper will introduce some of our efforts trying to weaken the effect of such Micro Noise during near-lossless compression. Experimental results on ISO test images and micro Gaussian noises demonstrate that with potentiality of filtering micro noise, an improved near-lossless coder can not only achieve obviously higher compression ratio but also provide better image fidelity (measured by mean squared error) than lossless coding.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.