A THz active scanned imaging system is developed for detection of concealed threat objects at a stand-off distance of 5 meters. Single pixel, active imaging system utilizes a continuous wave transceiver unit operating at 340 GHz, based on RF components and Schottky diode rectifiers. The transceiver has a heterodyne detection geometry and has 7 mW total power output which is derived from a 3dB directional coupler (25 dB directivity) and a horn antenna. 2D opto-mechanical scanning is performed using two mirror coupled galvanometer scanners to scan 50x50 cm2 field of view at 5 meters stand-off distance. 2 cm resolution is achieved on the target plane. Based on the opto-mechanical scan speed, frame rate is 2 Hz.
340 GHz provides penetration to common barrier objects such as clothing for detection of concealed threats. Here we present imaging capability of the system and its penetration abilities. Effect of barrier objects to the dynamic range is also investigated. To provide real time screening of the target scene for potential threat objects, its visual image is combined with the acquired THz image of the field of view by using image fusion technique.
Plasma, used as a terahertz (THz) detection medium has promising features. Several studies for mm-wave/THz radiation detection using various kind of methods for plasma creation such as neon indicator lamps [1], gas cells [2] and laser-induced air plasma [3] have been conducted. The interaction between the plasma and various frequency EM waves are still being investigated and in the mm-wave/terahertz range the interaction mechanism is still not well understood.
In this study a home-built gas chamber with variable electrode separation is studied using a continuous wave mm-wave/THz measurement systems. A breakdown is induced in gas mixture by applying a bias DC voltage to the electrodes and under sufficient conditions the modulated incident radiation can generate variations in the plasma current which can be measured electronically. The main mechanism of detection is the addition of the electric field of the incident EM radiation to the DC bias field, increasing the total electric field thus excitation collisions. Therefore the EM field is expected to effect the rate of ionization and excitation collisions at most at the regions with maximum total electron energy that is around the cathode dark space [4]. Depending on the orientation of its polarization, the incident EM radiation can also diffuse the signal electrons to the walls of the chamber giving rise to a negative change in bias current, decreasing the signal. Therefore the internal signal gain depends on the electrode geometry and polarization of radiation besides other parameters of the plasma.
Several parameters, such as gas pressure, gas species, discharge current, electrode spacing and electrode geometry effect the plasma-THz interaction thus changing the responsivity of the device. The plasma – THz interaction is studied here using a VDI multiplied source (WR2.8AMC). Driven by a frequency tunable Yttrium Iron Garnett (YIG) oscillator the source was modulated electronically providing a frequency tunable output in the 82-125 GHz and 246-375 GHz frequency range by use of a passive tripler. For the gas chamber different gases and gas mixtures are used. Using a Penning mixture, which is a mixture of one type of another gas with miniscule amount of another gas which has a lower ionization voltage than the main gas, a breakdown voltage lower than that of both gases can be obtained. Measurement of changes in the plasma current are carried out for different incident radiation frequencies, different electrode geometries, various gas mixtures and different modulation frequencies.
Graphene is proving to be an efficient medium for the control of mm-wave/THz radiation. Its electrical and dielectric properties allows it to be incorporated into various existing device architectures. One such application is in the modulation of the amplitude of the propagating THz radiation. Due to its electrical properties this interaction is typically broadband in nature. To make this frequency selective we propose the use of metamaterials or frequency selective surfaces. Generally, these structures perform the frequency filtering by modifying the propagation of the input wave with respect to changing structural parameters of the device itself. By fabricating a frequency selective surface based on a periodic circular hole array on an aluminum sheet we show that the transmission of a narrow band of THz radiation can be modulated when the sheet is combined with a highly efficient graphene based supercapacitor device. The modulation depth of the device was 15% in the frequency region of interest. The simple structure of the device coupled with the obtained performance shows that graphene based devices have great potential for the development of THz technologies.
New methods are being developed for efficient detection of terahertz waves. While many detection techniques show promise their commercial development is still limited due to the overall complexity and cost of the imaging system. Using commercially available neon indicator lamps the interaction mechanism between the glow plasma and the millimeter / THz wave is investigated in detail as a function of the device speed, sensitivity to frequency and polarization of the light. A lock-in amplifier was used to measure the response up to 90kHz when the GDD was placed at the focus of a 113GHz center frequency reconfigured Dielectric Resonating Oscillator (DRO) driven multiplied Schottky diode source. In addition the polarization sensitivity of the GDD was tested for two different scenarios whereby rotating the GDD the detected signal is observed to agree well with Malus’s Law for one particular orientation. Furthermore, the frequency dependent GDD-THz interactions are investigated using a 240-380 GHz tunable continuous wave radiation source. Employing both systems allow us to understand the response of GDDs with respect to modulation frequency, RF frequency and polarization orientation. Resonance effects, frequency sensitivity and geometrical structures of GDDs are studied for the purpose of obtaining better performance in THz-GDD interaction for applications including general THz wave detection and imaging.
In this work sub-terahertz imaging using Compressive Sensing (CS) techniques for targets placed behind a visibly opaque barrier is demonstrated both experimentally and theoretically. Using a multiplied Schottky diode based millimeter wave source working at 118 GHz, metal cutout targets were illuminated in both reflection and transmission configurations with and without barriers which were made out of drywall. In both modes the image is spatially discretized using laser machined, 10 × 10 pixel metal apertures to demonstrate the technique of compressive sensing. The images were collected by modulating the source and measuring the transmitted flux through the apertures using a Golay cell. Experimental results were compared to simulations of the expected transmission through the metal apertures. Image quality decreases as expected when going from the non-obscured transmission case to the obscured transmission case and finally to the obscured reflection case. However, in all instances the image appears below the Nyquist rate which demonstrates that this technique is a viable option for Through the Wall Reflection Imaging (TWRI) applications.
Due to the limited number of array detection architectures in the millimeter wave to terahertz region of the electromagnetic spectrum, imaging schemes with scan architectures are typically employed. In these configurations the interplay between the frequencies used to illuminate the scene and the optics used play an important role in the quality of the formed image. Using a multiplied Schottky-diode based terahertz transceiver operating at 340 GHz, in a stand-off detection scheme; the effect of image quality of a metal target was assessed based on the scanning speed of the galvanometer mirrors as well as the optical system that was constructed. Background effects such as leakage on the receiver were minimized by conditioning the signal at the output of the transceiver. Then, the image of the target was simulated based on known parameters of the optical system and the measured images were compared to the simulation. By using an image quality index based on χ2 algorithm the simulated and measured images were found to be in good agreement with a value of χ2 = 0 .14. The measurements as shown here will aid in the future development of larger stand-off imaging systems that work in the terahertz frequency range.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.