2 December 2016 INSIDE in-beam positron emission tomography system for particle range monitoring in hadrontherapy
Maria Giuseppina Bisogni, Andrea Attili, Giuseppe Battistoni, Nicola Belcari, Niccolo’ Camarlinghi, Piergiorgio Cerello, Silvia Coli, Alberto Del Guerra, Alfredo Ferrari, Veronica Ferrero, Elisa Fiorina, Giuseppe Giraudo, Eleftheria Kostara, Matteo Morrocchi, Francesco Pennazio, Cristiana Peroni, Maria Antonietta Piliero, Giovanni Pirrone, Angelo Rivetti, Manuel D. Rolo, Valeria Rosso, Paola Sala, Giancarlo Sportelli, Richard Wheadon
Author Affiliations +
Abstract
The quality assurance of particle therapy treatment is a fundamental issue that can be addressed by developing reliable monitoring techniques and indicators of the treatment plan correctness. Among the available imaging techniques, positron emission tomography (PET) has long been investigated and then clinically applied to proton and carbon beams. In 2013, the Innovative Solutions for Dosimetry in Hadrontherapy (INSIDE) collaboration proposed an innovative bimodal imaging concept that combines an in-beam PET scanner with a tracking system for charged particle imaging. This paper presents the general architecture of the INSIDE project but focuses on the in-beam PET scanner that has been designed to reconstruct the particles range with millimetric resolution within a fraction of the dose delivered in a treatment of head and neck tumors. The in-beam PET scanner has been recently installed at the Italian National Center of Oncologic Hadrontherapy (CNAO) in Pavia, Italy, and the commissioning phase has just started. The results of the first beam test with clinical proton beams on phantoms clearly show the capability of the in-beam PET to operate during the irradiation delivery and to reconstruct on-line the beam-induced activity map. The accuracy in the activity distal fall-off determination is millimetric for therapeutic doses.
© 2016 Society of Photo-Optical Instrumentation Engineers (SPIE) 2329-4302/2016/$25.00 © 2016 SPIE
Maria Giuseppina Bisogni, Andrea Attili, Giuseppe Battistoni, Nicola Belcari, Niccolo’ Camarlinghi, Piergiorgio Cerello, Silvia Coli, Alberto Del Guerra, Alfredo Ferrari, Veronica Ferrero, Elisa Fiorina, Giuseppe Giraudo, Eleftheria Kostara, Matteo Morrocchi, Francesco Pennazio, Cristiana Peroni, Maria Antonietta Piliero, Giovanni Pirrone, Angelo Rivetti, Manuel D. Rolo, Valeria Rosso, Paola Sala, Giancarlo Sportelli, and Richard Wheadon "INSIDE in-beam positron emission tomography system for particle range monitoring in hadrontherapy," Journal of Medical Imaging 4(1), 011005 (2 December 2016). https://doi.org/10.1117/1.JMI.4.1.011005
Published: 2 December 2016
Lens.org Logo
CITATIONS
Cited by 55 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Positron emission tomography

Monte Carlo methods

Imaging systems

Atmospheric particles

Head

Particle systems

Polymethylmethacrylate

Back to Top