A comprehensive design of experiment was elaborated to evaluate the effects of frame flatness, mask adhesive compliance, and mounting load on pellicle-induced distortions for soft pellicle systems. A dynamic mechanical analyzer was used to determine the elastic modulus of the adhesives materials, and a capacitive sensor-based tool was employed to measure the pellicle frame bow prior to mounting. Registration measurements were conducted on test reticles on a 21 X 21 array of grid points, before and after pellicle attachment. Statistical analysis (Anova test) was conducted to determine if the means for each sample group were statistically discernable. Overall, the magnitude of the distortions was very low for the pellicle mounting mechanism selected. Nevertheless the results indicated that the sample group with the flexible (softer) mask adhesive material exhibited lower distortions than that with conventional (stiffer) mask adhesive. Either larger sample size and/or wider variations in initial frame bow and mounting pressure will be required to assess the impact of these parameters on pellicle-induced distortions. Flexible (softer) mask adhesives are believed to minimize photomask deformation during the mounting process, resulting in lower pellicle-induced distortions.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.