A thorough evaluation of the effect of plasma protein binding in the estimation of receptor concentration was performed for the paired-agents in this study. We are planning to evaluate ABY-029, an anti-epithelial growth factor receptor (EGFR) Affibody, and IRDye 700DX as a control agent. The plasma-dependent change in fluorescence intensity, percent binding, and in vivo distribution kinetics will be studied for each agent alone, and in combination. In this proceeding, the absorption, emission patterns for the targeted agent, ABY-029, measured by UV-Vis, fluorometer, and Pearl were shown. Initial studies indicate that binding to Bovine serum albumin (BSA), human serum albumin (HSA) and EGFR can introduce the Solvatochromic shift, which will change the absorption and emission pattern for ABY-029. Computational modeling will be performed to determine how each of these changes will affect the determined BP, and thus detection of tumors from normal tissue.
Lymph node biopsy is a primary means of staging breast cancer, yet standard pathological techniques are time-consuming and typically sample less than 1% of the total node volume. A low-cost fluorescence optical projection tomography (OPT) protocol is demonstrated for rapid imaging of whole lymph nodes in three dimensions. The relatively low scattering properties of lymph node tissue can be leveraged to significantly improve spatial resolution of lymph node OPT by employing angular restriction of photon detection. It is demonstrated through porcine lymph node metastases models that simple filtered-backprojection reconstruction is sufficient to detect and localize 200-μm-diameter metastases (the smallest clinically significant) in 1-cm-diameter lymph nodes.
The potential to image subsurface fluorescent contrast agents at high spatial resolution has facilitated growing interest in short-wave infrared (SWIR) imaging for biomedical applications. The early but growing literature showing improvements in resolution in small animal models suggests this is indeed the case, yet to date, images from larger animal models that more closely recapitulate humans have not been reported. We report the first imaging of SWIR fluorescence in a large animal model. Specifically, we imaged the vascular kinetics of an indocyanine green (ICG) bolus injection during open craniotomy of a mini-pig using a custom SWIR imaging instrument and a clinical-grade surgical microscope that images ICG in the near-infrared-I (NIR-I) window. Fluorescence images in the SWIR were observed to have higher spatial and contrast resolutions throughout the dynamic sequence, particularly in the smallest vessels. Additionally, vessels beneath a surface pool of blood were readily visualized in the SWIR images yet were obscured in the NIR-I channel. These first-in-large-animal observations represent an important translational step and suggest that SWIR imaging may provide higher spatial and contrast resolution images that are robust to the influence of blood.
The goal of this work was to successfully deploy and test an intra-nodal cancer-cell injection model to enable planar fluorescence imaging of a clinically relevant blue dye, specifically methylene blue – used in the sentinel lymph node procedure – in normal and tumor-bearing animals, and subsequently segregate tumor-bearing from normal lymph nodes. This direct-injection based tumor model was employed in athymic rats (6 normal, 4 controls, 6 cancer-bearing), where luciferase-expressing breast cancer cells were injected into axillary lymph nodes. Tumor presence in nodes was confirmed by bioluminescence imaging before and after fluorescence imaging. Lymphatic uptake from the injection site (intradermal on forepaw) to lymph node was imaged at approximately 2 frames/minute. Large variability was observed within each cohort.
View contact details