There are several noninvasive techniques for assessing the kinetics of tear film, but no comparative studies have been conducted to evaluate their efficacies. Our aim is to test and compare techniques based on high-speed videokeratoscopy (HSV), dynamic wavefront sensing (DWS), and lateral shearing interferometry (LSI). Algorithms are developed to estimate the tear film build-up time TBLD, and the average tear film surface quality in the stable phase of the interblink interval TFSQAv. Moderate but significant correlations are found between TBLD measured with LSI and DWS based on vertical coma (Pearson's r2=0.34, p<0.01) and higher order rms (r2=0.31, p<0.01), as well as between TFSQAv measured with LSI and HSV (r2=0.35, p<0.01), and between LSI and DWS based on the rms fit error (r2=0.40, p<0.01). No significant correlation is found between HSV and DWS. All three techniques estimate tear film build-up time to be below 2.5 sec, and they achieve a remarkably close median value of 0.7 sec. HSV appears to be the most precise method for measuring tear film surface quality. LSI appears to be the most sensitive method for analyzing tear film build-up.
Interferometry is a sensitive technique for recording tear film surface irregularities in a noninvasive manner. At the same time, the technique is hindered by natural eye movements resulting in measurement noise. Estimating tear film surface quality from interferograms can be reduced to a spatial-average-localized weighted estimate of the first harmonic of the interference fringes. However, previously reported estimation techniques proved to perform poorly in cases where the pattern fringes were significantly disturbed. This can occur in cases of measuring tear film surface quality on a contact lens on the eye or in a dry eye. We present a new estimation technique for extracting the first harmonic from the interference fringes that combines the traditional spectral estimation techniques with morphological image processing techniques. The proposed technique proves to be more robust to changes in interference fringes caused by natural eye movements and the degree of dryness of the contact lens and corneal surfaces than its predecessors, resulting in tear film surface quality estimates that are less noisy.
A lateral shearing interferometer was used to examine the smoothness of the tear film. The information about the distribution and stability of the precorneal tear film is carried out by the wavefront reflected from the surface of tears and coded in interference fringes. Smooth and regular fringes indicate a smooth tear film surface. On corneae after laser in situ keratomileusis (LASIK) or radial keratotomy (RK) surgery, the interference fringes are seldom regular. The fringes are bent on bright lines, which are interpreted as tear film breakups. The high-intensity pattern seems to appear in similar location on the corneal surface after refractive surgery. Our purpose was to extract information about the pattern existing under the interference fringes and calculate its shape reproducibility over time and following eye blinks. A low-pass filter was applied and correlation coefficient was calculated to compare a selected fragment of the template image to each of the following frames in the recorded sequence. High values of the correlation coefficient suggest that irregularities of the corneal epithelium might influence tear film instability and that tear film breakup may be associated with local irregularities of the corneal topography created after the LASIK and RK surgeries.
The lateral shearing interferometer was applied to in vivo investigate the stability of the tear film surface covering
the contact lenses. The 8 mW HeNe laser was used as the light source. The sequences of interferograms were recorded
by CCD camera in real time during the inter-blink intervals at 25 fps, stored in a computer memory and numerically
processed. Every frame illustrates the pattern of interference fringes that corresponds to temporal stage of prelens tear
film surface. Fast Fourier Transform was used to quantitative evaluate tear film surface irregularities and the numerical
measure M2 was used to obtain quantitative description of the tear film smoothness. The M2 index is the lowest for the
smooth and regular surface of the tear film and its values increase if the prelens tear film begins to be unstable.
The proposed way of analysis of each interferogram gives opportunity to calculate the credibility of given M2 index and
automatically reject a part of a frame, that is not covered by interference fringes with an appropriate contrast due to eye
movement. The tear film smoothness has been measured on different types of soft contact lenses of 4 companies. The
significance differences in tear film stability have been noticed between low and high water content materials of contact
lenses. The tear film was less stable on low water content materials.
The purpose of this study is to investigate the kinetics of precorneal tear film stabilization process after eye blink and the process of creating the break-up of the tear film layer. The tear film of patients were examined in vivo by used the lateral shearing interferometer. The information about the distribution and stability of the tear film over the cornea is carried by the wave front reflected from the surface of tears and coded in interference fringes. Smooth and regular fringes indicate the smooth surface of tears over the cornea. Immediately after eye blink the interference fringes are observed on background of bright and dark areas. The contrast of this structure fades with time slowly and after 1-3 sec the background of interference fringes becomes uniform. The vertical orientation and instability of this structure suggests connection with eyelid movement and the spread of tears. If the eye is kept open for a long time, bright lines appear in the background of fringes after a dozen seconds. The slowly appearing structure might signify the tear film break-up. In case of eyes after a LASIK surgery the shape of the background structure has different nature and might be stable in time suggesting the stability of the corneal surface irregularities.
Tear film stability plays an important role in the quality of vision. We present an interferometric method for assessing the stability of precorneal tear film in real time. A lateral shearing technique is applied as a noninvasive and sensitive method for investigating tear film stability and the smoothness of the tear film surface by quantitative evaluation of the interference fringe pattern. The evaporation of tears and the appearance of tear film break-up between blinks cause changes in the fringe geometry. For quantitative assessment of the fringe smoothness and consequently of the tear film structure, the fast Fourier transform (FFT) is applied. Four parameters are used to quantitatively estimate dynamic changes in the tear film stability of the cornea 20 s after the eye blink. Examples of examined interferograms recorded in patients with healthy eyes, patients suffering from dry-eye syndrome, and patients wearing contact lenses are given. Significant differences between the stability of the tear film in the healthy eye and that in the dry eye and the eye with a contact lens are observed. The favorable influence of artificial tears applied in patients with dry-eye syndrome or contact lenses is also discussed.
The pre-ocular tear film is the most anterior refractive surface of the eye. Its stability plays an important role in the condition of vision from the optical and physiological point of view. If the eye is opened for a significantly long time or suffers from an anormalities in tear production, there appear isolated dry islands - break-ups - with a random distribution in the continuous lacrimal film. We applied an interferometric method - Lateral Shearing Technique for investigating the tear film stability and the smoothness of the tear film surface. This method is non-invasive and it is characterised by the high accuracy and sensitivity. Interferometry allows dynamic measurements of the tear film stability in real time by observation of interference fringes. The evaporation of tears and appearance of the breakups causes changes in the fringe geometry. Fast Fourier Transform has been used for quantitative assessment of the fringe smoothness and as a consequence of the tear film surface geometry. This paper presents the method used for quantitative evaluation of the tear film distribution on the cornea. Examples of interferograms recorded on eyes of patients with healthy eyes, suffering from dry eye syndrome and wearing contact lenses are also given. With our technique we were able to observe distinct differences in stability of the tear film between healthy and dry eyes, and the tear film on contact lenses.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please