Purpose: To evaluate the performance of an experimental X-ray dark-field radiography system for chest imaging in humans and to compare with conventional diagnostic imaging. Materials and Methods: The study was institutional review board (IRB) approved. A single human cadaver (52 years, female, height: 173 cm, weight: 84 kg, chest circumference: 97 cm) was imaged within 24 hours post mortem on the experimental x-ray dark-field system. In addition, the cadaver was imaged on a clinical CT system to obtain a reference scan. The grating-based dark-field radiography setup was equipped with a set of three gratings to enable grating-based dark-field contrast x-ray imaging. The prototype operates at an acceleration voltage of up to 70 kVp and with a field-of-view large enough for clinical chest x-ray (>35 x 35 cm2). Results: It was feasible to extract x-ray dark-field signal of the whole human thorax, clearly demonstrating that human x-ray dark-field chest radiography is feasible. Lung tissue produced strong scattering, reflected in a pronounced x-ray dark-field signal. The ribcage and the backbone are less prominent than the lung but are also distinguishable. Finally, the soft tissue is not present in the dark-field radiography. The regions of the lungs affected by edema, as verified by CT, showed less dark-field signal compared to healthy lung tissue. Conclusion: Our results reveal the current status of translating dark-field imaging from a micro (small animal) scale to a macro (patient) scale. The performance of the experimental x-ray dark-field radiography setup offers, for the first time, obtaining multi-contrast chest x-ray images (attenuation and dark-field signal) from a human cadaver.
Lukas Gromann, Kai Scherer, Andre Yaroshenko, Deniz Bölükbas, Katharina Hellbach, Felix Meinel, Margarita Braunagel, Oliver Eickelberg, Maximilian Reiser, Franz Pfeiffer, Silke Meiners, Julia Herzen
Purpose: The purpose of the present study was to evaluate if x-ray dark-field imaging can help to visualize lung cancer in mice. Materials and Methods: The experiments were performed using mutant mice with high-grade adenocarcinomas. Eight animals with pulmonary carcinoma and eight control animals were imaged in radiography mode using a prototype small-animal x-ray dark-field scanner and three of the cancerous ones additionally in CT mode. After imaging, the lungs were harvested for histological analysis. To determine their diagnostic value, x-ray dark-field and conventional attenuation images were analyzed by three experienced readers in a blind assessment. Results radiographic imaging: The lung nodules were much clearer visualized on the dark-field radiographs compared to conventional radiographs. The loss of air-tissue interfaces in the tumor leads to a significant loss of x-ray scattering, reflected in a strong dark-field signal change. The difference between tumor and healthy tissue in terms of x-ray attenuation is significantly less pronounced. Furthermore, the signal from the overlaying structures on conventional radiographs complicates the detection of pulmonary carcinoma. Results CT imaging: The very first in-vivo CT-imaging results are quite promising as smaller tumors are often better visible in the dark-field images. However the imaging quality is still quite low, especially in the attenuation images due to un-optimized scanning parameters. Conclusion: We found a superior diagnostic performance of dark-field imaging compared to conventional attenuation based imaging, especially when it comes to the detection of small lung nodules. These results support the motivation to further develop this technique and translate it towards a clinical environment.
Andre Yaroshenko, Felix Meinel, Katharina Hellbach, Martin Bech, Astrid Velroyen, Mark Müller, Fabian Bamberg, Konstantin Nikolaou, Maximilian Reiser, Ali Yildirim, Oliver Eickelberg, Franz Pfeiffer
Chronic obstructive pulmonary disease (COPD) is one of the leading causes of morbidity and mortality worldwide and
emphysema is one of its main components. The disorder is characterized by irreversible destruction of the alveolar walls
and enlargement of distal airspaces. Despite the severe changes in the lung tissue morphology, conventional chest
radiographs have only a limited sensitivity for the detection of mild to moderate emphysema. X-ray dark-field is an
imaging modality that can significantly increase the visibility of lung tissue on radiographic images. The dark-field
signal is generated by coherent, small-angle scattering of x-rays on the air-tissue interfaces in the lung. Therefore,
morphological changes in the lung can be clearly visualized on dark-field images. This is demonstrated by a preclinical
study with a small-animal emphysema model. To generate a murine model of pulmonary emphysema, a female
C57BL/6N mouse was treated with a single orotracheal application of porcine pancreatic elastase (80 U/kg body weight)
dissolved in phosphate-buffered saline (PBS). Control mouse received PBS. The mice were imaged using a small-animal
dark-field scanner. While conventional x-ray transmission radiography images revealed only subtle indirect signs of the
pulmonary disorder, the difference between healthy and emphysematous lungs could be clearly directly visualized on the
dark-field images. The dose applied to the animals is compatible with longitudinal studies. The imaging results correlate
well with histology. The results of this study reveal the high potential of dark-field radiography for clinical lung imaging.
The main shortcoming of conventional biomedical x-ray imaging is the weak soft-tissue contrast caused by the small differences in the absorption coefficients between different materials. This issue can be addressed by x-ray phasesensitive imaging approaches, e.g. x-ray Talbot-Lau grating interferometry. The advantage of the three-grating Talbot-Lau approach is that it allows to acquire x-ray phase-contrast and dark-field images with a conventional lab source. However, through the introduction of the grating interferometer some constraints are imposed on the setup geometry. In general, the grating pitch and the mean x-ray energy determine the setup dimensions. The minimal length of the setup increases linearly with energy and is proportional to p2, where p is the grating pitch. Thus, a high-energy (100 keV) compact grating-based setup for x-ray imaging can be realized only if gratings with aspect-ratio of approximately 300 and a pitch of 1-2 μm were available. However, production challenges limit the availability of such gratings. In this study we consider the use of non-binary phase-gratings as means of designing a more compact grating interferometer for phase-contrast imaging. We present simulation and experimental data for both monochromatic and polychromatic case. The results reveal that phase-gratings with triangular-shaped structures yield visibilities that can be used for imaging purposes at significantly shorter distances than binary gratings. This opens the possibility to design a high-energy compact setup for x-ray phase-contrast imaging. Furthermore, we discuss different techniques to achieve triangular-shaped phase-shifting structures.
We have developed a compact grating-based in-vivo phase-contrast micro-CT system with a rotating gantry. The 50 W microfocus x-ray source operates with 20 to 50 kV peak energy. The length of the rotating interferometer is around 47 cm. Pixel size in the object is 30 micron; the field of view is approx. 35 mm in diameter, suited to image a mouse. The interferometer consists of three gratings: an absorption grating close to the x-ray source, a phase grating to introduce a π/2 phase shift and an absorption analyzer grating positioned at the first fractional Talbot distance. Numerous drives and actuators are used to provide angular and linear grating alignment, phase stepping and object/gantry precision positioning. Phantom studies were conducted to investigate performance, accuracy and stability of the scanner. In particular, the influences of gantry rotation and of temperature fluctuations on the interferometric image acquisition were characterized. Also dose measurements were performed. The first imaging results obtained with the system show the complementary nature of phase-contrast micro-CT images with respect to absorption-based micro-CT. Future improvements, necessary to optimize the scanner for in-vivo small-animal CT scanning on a regular and easy-to-use basis, are also discussed.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.