Open Access
7 June 2016 Characterization of spatial–temporal patterns in dynamic speckle sequences using principal component analysis
José Manuel López-Alonso, Eduardo Grumel, Nelly Lucía Cap, Marcelo Trivi, Héctor Rabal, Javier Alda
Author Affiliations +
Abstract
Speckle is being used as a characterization tool for the analysis of the dynamics of slow-varying phenomena occurring in biological and industrial samples at the surface or near-surface regions. The retrieved data take the form of a sequence of speckle images. These images contain information about the inner dynamics of the biological or physical process taking place in the sample. Principal component analysis (PCA) is able to split the original data set into a collection of classes. These classes are related to processes showing different dynamics. In addition, statistical descriptors of speckle images are used to retrieve information on the characteristics of the sample. These statistical descriptors can be calculated in almost real time and provide a fast monitoring of the sample. On the other hand, PCA requires a longer computation time, but the results contain more information related to spatial–temporal patterns associated to the process under analysis. This contribution merges both descriptions and uses PCA as a preprocessing tool to obtain a collection of filtered images, where statistical descriptors are evaluated on each of them. The method applies to slow-varying biological and industrial processes.

1.

Introduction

Speckle analysis and speckle interferometry have been used to obtain deformations, topography, and roughness characteristics of a wide variety of samples. Also, when considered dynamically, speckle helps to characterize the temporal evolution of changes in the shape of observed objects.1 Speckle analysis techniques use the variations in intensity, polarization, and statistics to obtain the desired parameters on the sample. Most of the analysis techniques are heuristic in origin, and their objective is mainly practical and adapted for a given environment or application. Artificial intelligence techniques have been incorporated, along with learning algorithms (supervised and nonsupervised), to segment and identify regions of interest within data.2,3 However, there is not a unique strategy for analyzing dynamic speckle images applicable to a wide variety of situations.

In this contribution, we merge together the outcomes of two well-established methods: principal component analysis (PCA) and image descriptors. PCA is a multivariate technique that has been successfully applied to characterize several kinds of spatial–temporal phenomena,4 such as 1/f noise,5,6 digital compression algorithms,7 and dynamical images. Its statistical foundation makes this approach robust and reliable, providing spatial and temporal information of interest for the given case. Statistical image descriptors have been proposed and used to summarize in a single number or as a map, the overall characteristics of the phenomena.810 These descriptors are usually simpler than the results from PCA and are computationally more economic from the point of view of time of calculation and resources allocation. On the other hand, PCA requires an additional layer of knowledge to be included within the analysis. As any other computational method, PCA always produces a result. This result needs expert interpretation and makes PCA more user-dependent, especially when reaching meaningful conclusions for a given problem. Only when incorporating the measurement conditions and the character of the data set, it is possible to link PCA results to meaningful physical magnitudes.

The application of PCA to biospeckle images has been already considered with quite promising results.9,11,12 In this paper, we apply PCA to a given sequence of dynamic speckle images. PCA allows filtering sequences with specific spatial–temporal patterns. Then typical image descriptors are evaluated and compared with the classical dynamic speckle analysis methods applied to original and PCA-filtered sequences. Using this strategy, it is possible to determine which PCA band reveals the region of interest for each descriptor. Also, the time scales of the different processes can be determined. The input data used in this paper consist of three video sequences of dynamic speckle. One of the sequences corresponds with the drying evolution of a painted coin, and the other two are obtained by registering the speckle images of a bruised apple at different times.

Section 2 describes how PCA works for a temporally ordered collection of speckle frames (a dynamic speckle sequence). At the same time, we briefly present the results obtained from PCA and how they can explain the inner dynamics of the data. Then, in Sec. 3, we define the most useful image descriptors that are calculated for each case obtained before. Finally, Sec. 4 summarizes the main conclusions obtained in this contribution.

2.

Principal Component Analysis

PCA has been widely used in a variety of fields and situations. It has been applied to reduce the dimensions of data and to extract their most meaningful components and structures. Dynamic speckle sequences are collections of frames taken at a given temporal rate. The light source is coherent and speckle patterns change dynamically due to variations in the observed specimen. However, as far as the object is globally static along the measurement, frames show correlation among them. This correlation is analyzed and sliced by PCA. From a geometrical point of view, PCA can be seen as a rotation transformation from an N-dimensional coordinate system (the original frames) to a new N-dimensional coordinate system, where the new frames show no correlation. A dynamic speckle sequence has N frames, Fi, each one having M pixels organized as a rectangular image. Each rectangular frame is rearranged as a vector containing as many elements as pixels in one frame, M. This reshaping of data is fully reversible and rectangular frames can be retrieved. To properly evaluate the desired parameters, we have transformed each vector containing each frame to zero-mean vectors. This is easily done by subtracting the mean of each frame to each one, F¯i=FiFi, where denotes averaging. The N vectors in the sequence are organized as an N×M matrix, and its covariance matrix, S, is calculated as an N×N matrix. The elements of the variance matrix of the original data set, Sij, are calculated as the scalar product of the zero-mean vectors representing frames i and j. Due to the character of the acquired dynamic speckle images, this matrix is not diagonal and shows correlations among original frames. PCA works by diagonalizing this covariance matrix, S.4,5 The results obtained from PCA are N eigenvalues (appearing at the diagonal of the new diagonalized matrix), λα; N principal components, PCα (uncorrleated frames); and N eigenvectors, Eα (describing the transformation from original to-and-from principal component frames), where α runs from 1 to N (we have chosen α to denote the index for the principal components and i for the original frames). Eigenvalues describe the variance associated with each principal component. Most of the time it is more useful to evaluate the relative weight of each eigenvalue, wα=λα/α=1Nλα. The algorithm involved in the calculation of the principal components organizes eigenvalues in decreasing order (λα>λα+1). Then the relative importance of a given principal component decreases when increasing its rank, α. Principal components, PCα, can be interpreted as speckle pseudoimages showing no correlation among them. Finally, eigenvectors can be organized as an N×N unitary matrix describing the rotation between the original frames, Fi, and the principal components, PCα. In summary, PCA allows to move from a correlated set of frames (original speckle sequences) to an uncorrelated sequence (principal components).4,5 This transformation is described as

Eq. (1)

PCα=i=1Nei,αF¯i,F¯i=α=1Nei,αPCα,
where ei,α are the N components of eigenvector Eα.

Although principal components show no correlation, some subsets of them could be connected by inner data uncertainties. This fact allows grouping principal components into processes.5 The grouping strategy analyzes the uncertainties of the eigenvalues and links together those consecutive eigenvalues with overlapping uncertainties. The eigenvectors associated with isolated eigenvalues (not overlapping uncertainties) typically show a quasiharmonic variation associated to a temporal frequency.6 Considering this grouping method and its temporal behavior, it is possible to classify the set of N principal components in classes showing different correlation properties and spatial–temporal patterns. This will be explained more in detail in Sec. 2.1. As a consequence of this classification strategy, it is possible to reconstruct a filtered version of the original sequence taking into account a selected collection of principal components. This is called principal component rectification, or PCA filtering, and it is given as a variation of Eq. (1)

Eq. (2)

Fi(P)=αPeiαPCα+Fi,
where P is the collection of indices labeling the principal components used in the filtering. The result of this calculation is a sequence of frames that can be analyzed by other methods. If P={1,2,,N}, then the original frame set is retrieved.

In this paper, we have applied PCA to three collections of frames obtained from two types of samples. Figure 1 shows the average frame for each collection. This averaging is made along the temporal dimension, and it is different from the individual frame spatial averaging used to apply the PCA method. The samples were illuminated with an expanded and attenuated 10 mW HeNe laser. The speckle images were then registered by a CCD camera (Pulnix TM-6CN, CCIR Standard, interlaced scanning, pixel size 8.6  μm×8.3  μm, objective lens f=50  mm, and F#=16), digitized by a frame grabber to 8 bits and stored in the memory of a personal computer.13 The first collection of data, collection A, is obtained from the drying process of a painted coin. In this case, a uniform film of paint was applied to an Argentinean 5 cents coin with topographic details in relief. The painted surface was then illuminated by the laser and 398 images (512×512  pixels2) were registered. From Fig. 1, the shape of the coin is clearly seen in collection A. Collections B and C are dynamic speckle sequences of an apple mechanically beaten. Collection B is obtained immediately after the beat and collection C is taken after half an hour. To detect the bruised region in the apple, we registered a sequence of 500 speckle images (300×300  pixels2) from a red delicious apple. The damage was caused by a controlled impact produced by letting fall a steel ball (diameter 21.9 mm and weight 133.6 g) from 20 cm height on the apple. The impact point is at the center of the bottom region of the image. For control purposes, a nonactive region (a steel blade) was included in the scene at the top-right corner of the image. The bruise could not be appreciated by visual inspection.

Fig. 1

Temporal mean of the frames for each data collection. Collection A is for the coin and collections B and C are for the apple.

OE_55_12_121705_f001.png

2.1.

Results from the Principal Component Analysis

After applying the grouping and classification strategies described previously, we begin analyzing the eigenvalues and the temporal spectrum of the eigenvectors. In the first row of Fig. 2, we plotted the eigenvalues for each collection of frames in a semilog graph. The vertical lines limit three different classes classified using the PCA results.5 The first class in this classification, P1, comprises all the principal components, eigenvalues, and eigenvectors characterized by an isolated eigenvalue. The third class, P3, collects all the components that are represented by eigenvalues grouped together in one single process. In this last case, the uncertainties of consecutive eigenvalues overlap successively. Finally, the second class, P2, includes intermediate principal components between classes P1 and P3. A summary of the results of this classification is given in Table 1. Because the first principal component is the one contributing the most, we have quantified its relative weight, w1, that is expressed as a percentage is 41.53%, 53.72%, and 56.16% of the total variance for the three collections of frames, A, B, and C, respectively. From Fig. 2, we can also check that the harmonic character of the eigenvectors is much clearer for the first eigenvectors (see middle row in Fig. 2) than for the eigenvectors corresponding to principal components of higher rank number.

Fig. 2

The columns correspond with the (a) coin and (b and c) apple sequences, respectively. The relative weights, wα, are plotted in the first row. The vertical lines denote the separation between different classes of dynamics classified in this paper. The first five eigenvectors are plotted in the central row. We may see how the dependence is quite close to a harmonic variation. Finally, the third row shows as a map the spectrum of the eigenvectors for the three data sets.

OE_55_12_121705_f002.png

Table 1

Classification of the principal components into classes for the three data sets.

Classes# rangeRelative weight: ∑α∈Pwα
P1 (A, B, C)[1:30], [1:36], [1:34]0.8718, 0.7692, 0.7803
P2 (A, B, C)[31:68], [37:127], [35:113]0.0749, 0.0945, 0.0818
P3 (A, B, C)[69:398], [128:500], [114:500]0.0534, 0.1363, 0.1379

In addition to these preliminary results obtained from PCA, after classifying the components into classes and using Eq. (2), we may reconstruct the original data taking into account only those principal components included in each class (see # range in Table 1). In Fig. 3, we present the original object before painting (image a), and one of the frames for the original and the three filtered sequences (b, c, d, and e, respectively) for data collection A. These images show how poor the information that can be extracted from a single speckle image is. Only the profile of the coin is faintly perceived as a local diminished contrast. Then to obtain relevant information, every sequence can be treated statistically using image descriptors applied to the PCA outcomes. Some preliminary results are revealed when evaluating the mean, standard deviation (STD), and the signal-to-noise ratio (SNR) of the frames for the third class, P3, for the coin data set (see Fig. 4). SNR is defined as the quotient between mean and STD maps. From these figures, we can already see the hidden topography. STD is also considered as a descriptor in Sec. 3.

Fig. 3

The original object is represented when illuminated by (a) incoherent light and (b) coherent light. Images (c), (d), and (e) are frames extracted from the three filtered sequences P1, P2, and P3, respectively.

OE_55_12_121705_f003.png

Fig. 4

The maps represent (a) the mean value and (b) STD for each pixel of the frames calculated along the whole sequence (398 frames) obtained for the third class (P3) of the coin data set. (c) SNR is calculated as the ratio between the mean and STD for each pixel. Hidden topography is revealed from the STD and signal-to-noise maps.

OE_55_12_121705_f004.png

The main advantage of PCA is revealed when analyzing the temporal characteristics described by the corresponding spectra (see bottom row in Fig. 2). Actually, as we have seen before, the grouping strategy defines three classes of sequences: P1, P2, and P3. For class P1, there exists a linear relation between the frequency associated to each eigenvector and its rank.6,14 Once this characteristic frequency is defined, it is possible to consider the relation between eigenvalues (denoting the importance of the principal component in the whole data set and given as a portion of the total variance of the data) and associated frequencies (obtained from the quasiharmonic dependence of the eigenvectors), as a power spectral density (PSD).6 Actually, when analyzing dynamic speckle sequences, this PSD follows a 1/f pattern, where PSD(ω)=A1/f/ωα, being α1.12 For classes P2 and P3, it is not possible to define a single frequency for each eigenvector. To simplify the analysis, we extend to classes P2 and P3 the linear relation obtained for class P1 between the rank and the characteristic frequency. The frequency obtained from this linear trend is considered as a central characteristic frequency associated to each principal component (see Fig. 2). This frequency and its corresponding time constants are used to define the temporal and frequency limits of the classes identified previously. Table 2 shows the time scales for the three data sets. Class P1 describes dynamic behavior with frequencies between 0 and flim,12. Class P2 corresponds with frequencies between flim,12 and flim,23. Finally, class P3 expresses temporal frequencies above flim,23 until the Nyquist frequency. The same discussion can be given in terms of time scales. The values in Table 2 have been obtained knowing that the frame rate is 30 fps for the coin data set (collection A) and 1.25 fps for the apple data set (collections B and C).

Table 2

Limit frequency and characteristics time constant

Data setflim,1−2 (Hz), τlim,1−2 (s)flim,2−3 (Hz), τlim,2−3 (s)
A (coin)1.125, 0.892.55, 0.39
B (apple t=0  h)0.045, 22.20.159, 6.30
C (apple t=0.5  h)0.043, 23.50.141, 7.08

From the previous analysis, it is possible to estimate the minimum resolvable spatial detail (spatial resolution) and the minimum resolvable time variation (temporal resolution). The spatial resolution is limited by the size of the speckle grain at the object plane, G, given as15

Eq. (3)

G1.2λF#(1+1/M),
where M is the lateral magnification of the image-forming system. For the coin data set, M=0.2. Then, using Eq. (3) and the experimental conditions, the size of the speckle grain is G75  μm. The estimation of the temporal resolution should consider the interaction between the 1/f PSD previously described12 and other sources of noise.6,16 A conservative estimation of the temporal evolution can be taken as limited by the characteristic time constant corresponding to the last frequency included within the first class. For the coin data set, this temporal limit would be τlim,12=0.89 s (see Table 2). By combining the spatial and temporal resolutions, it is possible to define a speckle speed limit corresponding to the first class as vlimit=G/τlim,12.

3.

Image’s Descriptors

Global and local descriptors have been proposed to determine spatial and temporal characteristics of a dynamic speckle sequence. Some of the findings of the analysis shown in this paper are related to the spatial identification of temporal phenomena. Then it seems reasonable to focus our attention on time-domain descriptors. They are given in terms of the value of the pixel located at a position (i,j), at a given frame, k, of the full N frames sequence: xk(i,j). Because of its importance in medical applications, we also include laser contrast analysis (LASCA) descriptor that requires only one frame for its calculation. These descriptors will be easily represented as maps. They are listed as follows:

  • STD: This parameter is calculated as the STD along the frames for each pixel and is defined as

    Eq. (4)

    STD(i,j)=σ=1Nk=1N[xk(i,j)μ(i,j)]2,
    where μ(i,j)=1Nk=1Nxk(i,j) is the mean value of the pixel (i,j) along the sequence.

  • Generalized differences (GDs): It takes into account the intensity variation at various time scales.17 It is given as

    Eq. (5)

    GD(i,j)=1Nk=1Nl=1Nk|xk(i,j)xk+l|.

  • Weighted generalized differences (WGDs): A variation of the GD parameter is defined by weighting the importance of consecutive frames in the sequence. This is made by setting a weight that works as a temporal window. This weight is denoted as p and takes a nonzero value only in those frames around the given frame. By doing this, the variation is enhanced when appearing temporarily around the frame. Its mathematical definition is

    Eq. (6)

    WGD(i,j)=k=1Nl=1Nk|xk(i,j)xk+l|p(l).
    A typical form of p(l) is a collection of 1 for several frames (5, 7, …) around the central frame (k), with the rest of the values of p(l)=0.

  • Subtraction average of consecutive differences (AVD): It is defined as the AVD along the sequence as18

    Eq. (7)

    AVD(i,j)=1N1k=1N1|xk(i,j)xk+1|.

  • Fujii’s differences (Fujii): This parameter is also a variation of the AVD parameter.19 It can be seen as the mean value of the temporal contrast between consecutive frames

    Eq. (8)

    Fujii(i,j)=1N1k=1N1|x(i,j)kx(i,j)k+1x(i,j)k+x(i,j)k+1|.

  • LASCA: This parameter takes into account the ratio of spatial STD to the mean value on a predefined spatial window around each pixel. When the sample is active within the given spatial window, the signals are averaged and the contrast is lower. Then active regions produce low values of this parameter.

3.1.

Analysis of Image’s Descriptors Using Principal Component Analysis

Figure 5 shows the descriptors, previously defined, and calculated for the coin experiment (arranged in rows). The evaluation has been done for the original sequence of frames and the filtered sequences corresponding to P1, P2, and P3 classes (organized in columns). The same pseudocoloring palette was used in all of them to decrease subjective bias. This analysis demonstrates that only WGD, AVD, and Fujii’s difference were able to distinguish hidden topography from the original dynamic speckle coin sequence. However, when any of the previously considered image’s descriptors were evaluated for the PCA-filtered sequence using only class P3 principal components [P={69,70,,398} in Eq. (2)], all descriptors provide meaningful information of the hidden topography under the paint. In addition, none of these global parameters provided topographic information when using filtered sequences corresponding to class P1 [P={1,2,,30} in Eq. (2)]. Using the temporal parameters given in Table 2, we could conclude that dynamics above flim,23=2.55  Hz reveals topography using any image descriptors. This means that high-frequency dynamics is dependent on the paint thicknesses, i.e., thinner regions are less active at high frequency than thicker areas. Contrarily, sequences involving frequencies below flim,12=1.125  Hz do not give topographic information independent of the image’s descriptor used in the analysis. In this case, PCA has provided a quite simple way to decouple processes acting at different temporal scales. Even more, some of the results have provided important information about hidden features of the object under analysis, even when observed within a temporal window much smaller than the typical time scales of the physical mechanism under study.

Fig. 5

Maps for the descriptor applied to the original and filtered sequences for the coin data.

OE_55_12_121705_f005.png

The bruised apple sequences have been treated in the same way as the coin. However, in this case, we are more interested in retrieving some information about the bioactivity of the sample. This is why we have performed the analysis with two sets of frames taken at different times: one sequence (collection B) is taken immediately after the apple has been bruised, t=0  h and the second sequence is taken after half an hour, t=0.5  h (collection C). In the analysis of the apple, we have focused our attention on the STD and Fujii descriptors because they showed a better performance when distinguishing the effect of the bruise. After evaluating them for original and filtered sequences of the two sets of data, they can be compared by calculating the difference in the descriptor’s map obtained at two different times after the beat. This analysis is shown in Fig. 6. The left column shows Fujii(t=0.5  h)Fujii(t=0.0  h), and the right column represents STD(t=0.5  h)STD(t=0.0  h). The location of the damage (center bottom of the image) is identified by this difference even when calculated with the original frame set (first row in Fig. 6). However, the capability of PCA to classify elements according to its temporal behavior allows a more detailed analysis. The beaten region is identified from filtered images P1, P2, and P3 (second, third, and fourth row in Fig. 6). Actually, although visible, this identification is a little harder for Fujii parameter calculated for the P1 class. With this analysis, we can infer some information about the dynamics of the process. Both Fujii and STD are larger at the beaten region just immediately after the beat than 30 min later for P2 and P3 classes. However, Fujii and STD are smaller at the beaten region for t=0  h than for t=0.5  h. As these classes are linked with temporal frequencies, this differential behavior means that lower frequency dynamics are more important half an hour after the beat than immediately after the damage is produced. The opposite can be said for higher frequencies (larger than flim,12) denoting that the beaten region stops changing at high frequencies. In this discussion, it is important to note that the importance of each class (evaluated by the relative weights presented in Table 1) does not change significantly from collection B (just after beating the apple) and collection C (half an hour after the beat). This approximate constancy emphasizes the reliability of PCA to analyze spatial–temporal patterns.

Fig. 6

Maps of the difference between t=0.5  h and t=0  h for (a) Fujii and (b) STD image descriptors. This difference is evaluated for the original set of frames (first row) and for those obtained after grouping together the principal components into classes P1 (second row), P2 (third row), and P3 (fourth row). The temporal frequencies involved in these classes are higher for class P3 and are lower for class P1. Class P2 corresponds with intermediate frequency variations. The color bar applies to both parameters only by adding a ×103 factor to the Fujii images.

OE_55_12_121705_f006.png

4.

Conclusions

The application of PCA to dynamic speckle sequences obtained from industrial processes and biological samples makes possible a spatial–temporal description of the data. In this contribution, we demonstrate this capability by studying two cases that appear in the literature: the drying process of paint over a given topography and the bruising of a fruit. After applying PCA, we see that the most contributing images are associated with harmonic temporal variations. In addition, these principal components are independent and cannot be connected through the uncertainty of data. On the other hand, those principal components with the lowest contributions can be grouped together because of the inner statistics relations among data. This grouping strategy defines three classes of sequences. The first one represents most of the variance of the original data. The third class represents noise variations and rapid fluctuations. In between these two classes, there is another one that defines intermediate time scales. Temporal frequencies are associated with each class. This association is clearer for the most contributing class corresponding with low-frequency variations. Even more, in this case, it is possible to define a power spectrum density.

For the coin drying data, the analysis of the original data reveals the hidden topography for the WGD, AVD, and Fujii parameters. However, this analysis cannot be associated with the quantitative evaluation of the involved time scales until studying the PCA results, where the three filtered sequences are associated to three different time scales and frequencies. In the coin case, the application of the descriptors shows that the topography under paint is mostly contained in class P3, corresponding to low eigenvalues. For the bruised apple experiment, the result shows that both the STD and Fujii descriptors identify the damaged region even from the original sequences. Again, only after analyzing PCA results and comparing them using sequences taken at different times after the bruising, is it possible to perceive some changes. We have seen that low-frequency dynamics is more important 30 min after the beat at the location of the damage. The opposite happens with medium- and high-frequency contributions. This means that half an hour after the beating, those processes involving rapid variations decrease.

Summarizing these results, we conclude that PCA is capable of revealing hidden contributions to the speckle variations. These contributions are easily related to separable time scales. This fact makes possible a quantitative and qualitative spatial–temporal description of the phenomena under analysis. In addition, the application of speckle descriptors to filtered sets of data improves the capability of identification of underlying biological or industrial time-dependent processes. Further improvement can be expected, if different descriptors are combined by using supervised or no supervised neural networks.

Acknowledgments

This work has been supported by the Ministerio de Economia y Competitividad of Spain through the Project No. TEC2013-40442, and CONICET, CIC, and UNLP, Argentina. This paper was a derivation of our previous conference contribution titled “Characterization of dynamic speckle sequences using principal component analysis and image descriptors.”20

References

1. 

H. Rabal and R. A. Braga, Dynamic Laser Speckle and Applications, CRC Press, Boca Raton, Florida (2008). Google Scholar

2. 

I. Passoni et al., “Probability mapping images in dynamic speckle classification,” Appl. Opt., 52 726 –733 (2013). http://dx.doi.org/10.1364/AO.52.000726 APOPAI 0003-6935 Google Scholar

3. 

L. I. Passoni et al., “Improvement in the visualization of segmented areas of patterns of dynamic speckle classification,” Advances in Self-Organizing Maps, 198 163 –171 Springer-Verlag, Heidelberg (2013). Google Scholar

4. 

I. T. Jolliffe, Principal Component Analysis, Springer, Berlin (2002). Google Scholar

5. 

J. M. López-Alonso, J. Alda and E. Bernabeu, “Principal components characterization of noise for infrared images,” Appl. Opt., 41 320 –331 (2002). http://dx.doi.org/10.1364/AO.41.000320 APOPAI 0003-6935 Google Scholar

6. 

J. M. López-Alonso and J. Alda, “Operational parameterization of the 1/f noise of a sequence of frames by means of the principal component analysis in focal plane arrays,” Opt. Eng., 42 (7), 1915 –1922 (2003). http://dx.doi.org/10.1117/1.1579490 Google Scholar

7. 

J. M. López-Alonso and J. Alda, “Characterization of artifacts in fully digital image-acquisition systems: application to web cameras,” Opt. Eng., 43 (1), 257 –265 (2004). http://dx.doi.org/10.1117/1.1626667 Google Scholar

8. 

G. H. Sendra et al., “Biospeckle descriptors: a performance comparison,” Proc. SPIE, 7387 73871K (2010). http://dx.doi.org/10.1117/12.870682 PSISDG 0277-786X Google Scholar

9. 

R. Nassif et al., “Detection of Golden apples’ climacteric peak by laser biospeckle measurements,” Appl. Opt., 53 (35), 8276 –8282 (2014). http://dx.doi.org/10.1364/AO.53.008276 APOPAI 0003-6935 Google Scholar

10. 

L. I. Passoni et al., “Signal feature extraction using granular computing. Comparative analysis with frequency and time descriptor applied to dynamic laser speckle patterns,” Int. J. Comput. Int. Syst., 8 28 –40 (2015). http://dx.doi.org/10.1080/18756891.2015.1129589 Google Scholar

11. 

K. M. Ribeiro et al., “Principal component analysis in the spectral analysis of the dynamic laser speckle patterns,” J. Eur. Opt. Soc. Rapid Publ., 9 14009 (2014). http://dx.doi.org/10.2971/jeos.2014.14009 Google Scholar

12. 

J. M. López-Alonso et al., “Dynamic speckle analysis using multivariate techniques,” J. Opt., 17 (3), 035609 (2015). http://dx.doi.org/10.1088/2040-8978/17/3/035609 Google Scholar

13. 

L. I. Passoni et al., “Dynamic speckle processing using wavelets based entropy,” Opt. Commun., 246 219 –228 (2005). http://dx.doi.org/10.1016/j.optcom.2004.10.054 OPCOB8 0030-4018 Google Scholar

14. 

E. R. Dougherty, Random Processes for Image and Signal Processing, SPIE Press, Bellingham, Washington (1998). Google Scholar

15. 

A. E. Ennos, “Speckle interferometry,” Laser Speckle and Related Phenomena, 203 –253 Springer, Berlin, Heidelberg (1975). Google Scholar

16. 

J. M. López-Alonso and J. Alda, “Conditions for the applicability of the principal component analysis to the characterization of the 1/f noise,” Fluctuation Noise Lett., 6 (1), L17 (2006). http://dx.doi.org/10.1142/S0219477506003100 Google Scholar

17. 

R. Arizaga et al., “Display of local activity using dynamical speckle patterns,” Opt. Eng., 41 (2), 287 –294 (2002). http://dx.doi.org/10.1117/1.1428739 Google Scholar

18. 

J. R. Braga et al., “Reliability of biospeckle image analysis,” Opt. Lasers Eng., 45 (3), 390 –395 (2007). http://dx.doi.org/10.1016/j.optlaseng.2006.07.002 Google Scholar

19. 

H. Fujii et al., “Evaluation of blood flow by laser speckle image sensing. Part 1,” Appl. Opt., 26 (24), 5321 –5325 (1987). http://dx.doi.org/10.1364/AO.26.005321 APOPAI 0003-6935 Google Scholar

20. 

J. M. López-Alonso et al., “Characterization of dynamic speckle sequences using principal component analysis and image descriptors,” Proc. SPIE, 9598 95980Q (2015). http://dx.doi.org/10.1117/12.2187978 Google Scholar

Biography

José Manuel López-Alonso received his Lic. degree in physics in 1994, and his PhD degree in 2002 from the University Complutense of Madrid (UCM), Spain. He is with the Optics Department of UCM as permanent faculty since 2008. He worked at the thermal vision laboratory of the Centro de Investigación y Desarrollo de la Armada since 1994 till 2002. From 2005 to 2006 he was with the University of Central Florida, Orlando, Florida. Since 2011 he coordinates the MS degree in "Optical and Image Technologies" at UCM.

Eduardo Grumel is a telecommunications engineer from the Universidad Nacional de La Plata. He has worked since 1990 as an assistant professor of electromagnetism in the Facultad de Ingeniería of the Universidad Nacional de La Plata. Since 1992 works in the Centro de Investigaciones Ópticas (CIOp) as professional research assistant. Since 2001, he has belonged to the group of optical metrology and image processing. His research interests include optical processing, optical metrology, and dynamical speckle techniques.

Nelly Lucía Cap received her MSc in computer engineering in 1985 from the University of La Plata, Argentina. She teaches mathematics in the Faculty of Economic Science of La Plata University. Since 1988 she has been a technical support member with CIOp under contract from the Scientific Research Commission of Buenos Aires (CICBA). His research interests include optical processing and dynamical speckle techniques.

Marcelo Trivi received his MS and PhD degrees in physics from the University of La Plata, Argentina, in 1979 and 1986, respectively. In 1982 he joined CIOp and served as vice director from 2006 to 2009 and director from 2010 to 2012. Since 1988 he became a researcher with the Buenos Aires Research Council (CICPBA), Argentina. He is a full professor with the Faculty of Engineering, University of La Plata. His research interests include optical processing, optical metrology, and dynamical speckle techniques.

Héctor Rabal received his MSc and PhD degrees from the National University of La Plata, Argentina, and did his postdoctoral work at the Munich Ludwig and Maximilian University and at the University of Paris. In 1977 he joined the Optical Research Center. Currently he is a principal researcher at the National Council for Scientific and Technologic Research of Argentina. He has been full professor at the National University of La Plata, his research interests include optical metrology, image processing, and applications of dynamic speckle.

Javier Alda graduated 1985 as Lic. in Sciences from the University of Zaragoza, and received his PhD degree in physics from UCM, Spain, in 1988. He joined the Optics Department of UCM in 1985, where he is full professor now. He has been a visiting researcher at the University of Central Florida, Stanford University, Universidad Autónoma de San Luis Potosí in México, and University of North Carolina at Charlotte. He is a fellow of SPIE.

CC BY: © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
José Manuel López-Alonso, Eduardo Grumel, Nelly Lucía Cap, Marcelo Trivi, Héctor Rabal, and Javier Alda "Characterization of spatial–temporal patterns in dynamic speckle sequences using principal component analysis," Optical Engineering 55(12), 121705 (7 June 2016). https://doi.org/10.1117/1.OE.55.12.121705
Published: 7 June 2016
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications and 1 patent.
Advertisement
Advertisement
KEYWORDS
Principal component analysis

Speckle

Speckle pattern

Optical engineering

Biological research

Statistical analysis

Image filtering

Back to Top