1.IntroductionThe hippocampus is a deeply embedded brain region, which plays a critical role in encoding new memories. In the hippocampus, as elsewhere in the mammalian brain, pyramidal neurons receive most of their excitatory synaptic input at dendritic spines, which are small protrusions in the postsynaptic membrane that house the postsynaptic signaling machinery including glutamate receptors. Structural and functional plasticity of dendritic spines is a fundamental neurobiological process that underlies all higher brain functions, such as memory, thought, and action,1,2 whereas spine dysfunction is closely associated with neuropsychiatric and neurodegenerative disorders, such as autism and Alzheimer’s disease.3 Two-photon fluorescence microscopy provides high depth penetration and optical sectioning in turbid media,4 making it the standard technique for imaging in acute brain slices5,6 and intact brains.7–9 Over the last 20 years, it has transformed our understanding of the structure and function of dendritic spines in mouse brain.10 Until now, most in vivo studies of dendritic spines have been limited to superficial layers of the cortex (somatosensory, motor, visual cortex),11–13 mainly because of the challenge to optically reach more deeply embedded structures. For example, the hippocampus is more than 1 mm below the cortical surface of the mouse brain. Only a few groups have ventured into imaging hippocampal spines in vivo, relying either on surgical resection of the overlaying cortex14,15 or a microendoscope with a gradient-index lens.16 However, 2-photon microscopy is a diffraction-limited approach, which offers at best a spatial resolution of around 350 nm laterally and axially, falling substantially short of visualizing several key neuro-anatomical structures and spaces, including spine necks, axon shafts, astroglial processes, and synaptic clefts, whose sizes can range well below 100 nm. As a consequence, there is a great need to develop and improve super-resolution imaging techniques that could be applied to deeply embedded regions, such as the hippocampus. Among the various super-resolution methods, stimulated emission depletion (STED) microscopy17 is currently the only one that has been successfully applied in vivo,18–22 notably in the hippocampus.23 STED microscopy is based on laser-scanning microscopy (such as confocal or 2-photon microscopy), where a Gaussian laser beam is focused to a small spot generating the fluorescence signal used to construct the image. In addition, there is a second laser (the STED laser), which exerts the opposite effect, namely it de-excites molecules by the process of stimulated emission. By spatially shaping the focal STED intensity like a donut,17 it is possible to suppress the spontaneous fluorescence in the peripheral region of the focal spot, narrowing down the effective point spread function (PSF) in the plane by up to an order of magnitude.24 By delivering STED light also above and below the focal region (a profile referred to as “bottle beam”), it becomes possible to constrict the fluorescence along the optical axis as well.25,26 In STED microscopy, spatial resolution and signal-to-noise ratio (SNR) of the images crucially depend on the quality of the PSF of the STED beam.27 Yet, maintaining a high-quality PSF inside light scattering brain tissue poses several challenges. This problem is particularly evident in the context of in vivo imaging, where a variety of biological and mechanical constrains stand in the way of ensuring sufficiently good optical conditions for STED imaging. Notably, long working distance water immersion objectives typically used for in vivo imaging are not optimal for STED. Indeed, the effective STED resolution scales nonlinearly with the numerical aperture (NA) of the objective lens.28 Hence, oil or glycerin immersion lens are typically preferred, offering high NA up to 1.49 at the expense of limited working distance. In addition to gain optical access to the brain, most studies rely on implanting a cranial window29 in which a small part of the skull is replaced by a coverslip. Consequently, the mechanical stability of the cranial window attachment as well as of the brain itself are crucial, since any vibrations stemming from muscle contractions, pulmonary breathing, and blood pulsations can produce motion artefacts and diminish image quality. The bottle beam PSF used for the axial gain in resolution is particularly sensitive to optical aberrations and misconfigurations in the beam path. Notably, the modified cranial window used to image the hippocampus15,24 reduced the effective NA, which prevented the use of a bottle beam profile for 3D-STED in our previous study based on a cylindrically shaped “hippocampal window.”23 In this paper, we propose the use of a conically shaped window, specifically designed to maintain the bottle beam profile, while minimizing the size of the surgical resection of the overlaying cortex. 2.Material and Methods2.1.2-Photon STED MicroscopeImaging was performed using a custom-built upright laser-scanning fluorescence microscope, as previously described.23,27,30 In brief, the 2-photon excitation beam (100 fs, 80 MHz, 900 nm) was provided by a femtosecond titanium:sapphire laser (Tsunami, Spectra-Physics), pumped by a high power continous wave diode pumped solid state laser (Millennia EV 15, Spectra-Physics), sent through a Pockels cell (302 RM, Conoptics) to control the excitation power. The STED beam (592 nm, 700 ps, 80 MHz) was provided by another pulsed laser (Katana 06 HP, NKT Photonics) whose power was adjustable using a half-wave plate and a polarization beam splitter. Both lasers were synchronized and temporally overlapped using commercial electronics (“Lock-to-clock,” Model 3930 and 3931, Spectra-Physics). The STED beam was passed via a spatial light modulator (SLM) (3D module, Abberior Instruments) to modulate the wavefront in a way that a donut or bottle beam intensity distribution of the STED light is achieved in the focal plane. Half and quarter-wave plates ( and ) were used to produce a left-handed circular polarization at the entrance pupil of the objective. Both 2-photon excitation and STED beams were combined using a long-pass dichroic mirror (DCSPXRUV—T700, AHF). Appropriate lens combinations were used to conjugate the SLM on a telecentric scanner (Yanus IV, TILL Photonics), which was then imaged on the back focal plane of the objective (CFI Apo NIR 60× W, NA 1.0, Nikon) mounted on a -focusing piezo actuator (Pifoc 725.2CD, Physik Instrumente). This objective provided a working distance of 2.8 mm, sufficient to bridge the physical distance between the surface of the brain and the deeply embedded hippocampus, while still offering a relatively high NA conducive for high-resolution imaging. The epifluorescence signal was descanned, separated from the incident beams using a long-pass dichroic mirror (580 DCXRUV, AHF) and detected by an avalanche photodiode (SPCM-AQRH-14-FC, Excelitas) with appropriate notch (594S-25, Semrock) and bandpass filters (680SP-25, 520-50, Semrock) along the emission path. Signal detection and hardware control were performed via a data acquisition card (PCIe-6259, National Instruments) and the Imspector software (Abberior Instruments). To visualize and prealign the donut or bottle PSFs, a pellicle beam splitter (BP145B1, Thorlabs) was flipped into the beam path to detect the signal reflected by gold beads (150 nm Gold nanospheres, Sigma Aldrich) using a photomultiplier tube (MD963, Excelitas). In the following, 2D-STED, -STED, and 3D-STED will refer to images acquired using a pure donut, a pure bottle beam or a combination of the two beams, respectively. Optical resolution was assessed by imaging fluorescent beads (yellow–green fluorescent beads, 40 or 170 nm in diameter, Invitrogen) immobilized on glass slides. 2.2.Animal ExperimentationWe used adult female and male transgenic mice (, 3 to 12 months old) where a subset of hippocampal neurons was fluorescently labeled with YFP.31 Heterozygous mice were used with sparse yet robust cytosolic labeling well adapted for high contrast superresolution imaging. The mice were group-housed by gender at a 12/12 h light/dark cycles. All procedures were in accordance with the Directive 2010/63/EU of the European Parliament and approved by the Ethics Committee of Bordeaux under agreement number 8899. 2.3.Hippocampal Window ImplantationChronic hippocampal windows were implanted as described previously14,15,23,32 to provide optical access to the Stratum oriens and Stratum pyramidale of the CA1 region of the hippocampus. In brief, mice were anesthetized with isoflurane (2%) and received intraperitoneal injections of analgesic (buprenorphine, ) and anti-inflammatory drugs (dexamethasone, ) to minimize brain swelling during the surgical procedure. The mouse scalp was shaved in the surgical region, and the mouse was placed into a stereotaxic frame with a heating pad. Lidocaine was locally applied prior to the removal of the skin and periosteum above the skull. A 3-mm-diameter craniotomy was performed above the right or left hemisphere using a dental drill (anteroposterior ; mediolateral +1.8 mm). The dura was carefully removed using fine forceps before aspiring the somatosensory cortex above the hippocampus using a vacuum pump connect to 29 G blunt needle. The overlying alveus was carefully peeled away to expose the surface of the hippocampus. A custom-made metal tube sealed with a coverslip (#1) on the bottom side (both 3 mm in diameter) was inserted into the craniotomy and tightly fixed to the skull with acrylic glue. Since our objective lens does not have a correction collar, this coverslip offers a good compromise between the thick #1.5 H coverslip, necessitating strong correction of spherical aberration with the SLM, and the thin #0 coverslip, which can be too fragile for cranial window implantation. Once in place, the hippocampal window was fixed using ultraviolet light curable dental cement. 2.4.In Vivo ImagingAfter the surgery, mice received analgesics for 2 days (buprenorphine, , intraperitoneal injection) and be allowed to recover for at least 4 weeks before starting imaging sessions. During these sessions, mice were anesthetized under 4% isoflurane prior to be transferred to a custom-made 3D printed tiltable frame, based on ear bars and nose fixations, incorporating a mask delivering 1.5% to 2% isoflurane at . The eyes were protected with ointment (bepanthen) and body temperature was maintained using a heating pad with anal probe. Imaging of CA1 pyramidal neurons was performed at 10 to depth to avoid scare tissue at the surface while limiting optical aberrations steaming from the sample.19,27 Typical image size was in with a pixel size of 20 nm, stacks typically extended over with a -step size of 100 nm. Images were acquired with a pixel dwell time, whereas excitation and STED laser powers were in the range of 10 to 20 mW after the objective lens. With these acquisition settings, no signs of phototoxicity were visible. 3.PSF ComputationThe PSF of the STED beam was calculated using vectorial diffraction theory by Richard and Wolf,33,34 which makes it possible to calculate the electromagnetic field () in an arbitrary point P close to the focal region of a high NA () objective, based on the Debye integral35,36 where is the wavenumber, the objective focal length, the solid angle of the exit pupil from the focal spot, the unit vector along each ray from the objective pupil to the focal volume, the complex amplitude of the incident laser beam after the objective and the position vector of point .Considering the geometry depicted in Fig. 1(a), the diffraction integral can be expressed, in spherical coordinates, as36,37 where is a constant, the wavenumber in the vacuum, the marginal ray angle, and the refractive indices and incident angle in the (1) immersion media, (2) the coverslip, and (3) the sample, respectively, the depth in the sample, the thickness of the coverslip, the amplitude profile of the incident beam, the polarization state of the electromagnetic field in the focal region, the phase profile of the input beam, corresponding in our case to the phase mask used to shape the STED beam, and the wavefront distortion with respect to the Gaussian reference sphere, which describes the optical aberrations in the system. Note that the second and third exponential terms correspond to the aberrations induced along the optical path through the coverslip and the biological sample.37Although passing through an aplanatic objective, the incident plane wave transforms into a spherical wave converging to the focal point. Therefore, assuming a Gaussian profile of the input beam, the amplitude distribution after the objective can be expressed as where is a constant, the beam waist, the cylindrical coordinate on the exit pupil of the objective lens, and the apodization term ensuring energy conservation while the beam pass through the objective. In addition, the objective transforms the input left-handed circular polarization , classically used in STED microscopy, through tight focalization, which can be described as where is the rotation matrix around axis, describe the change in electric field as it passes through the objective, corresponds to the coordinate system rotation in medium , and is the matrix describing the effect of the coverslip medium, considered as a stratified medium of two interfaces where is the transmission coefficient in the coverslip (see37 for complete derivation).Finally, in the case of left-handed circular polarization In the context of STED microscopy, the PSF of the STED beam is spatially shaped [Fig. 1(c)—top profiles] using specific phase masks , that can be expressed as where is the angle between the optical axis and the ray passing through the edge of the -phase ring of the phase mask of radius on the objective output pupil of radius [Fig. 2(d)—top panel].The focal intensity can be calculated as the squared modulus of the electric field Finally, the effective PSF [Fig. 1(c)—bottom profiles] is calculated as38 where and are the excitation and STED beams, respectively, and is the saturation intensity, which describes the de-excitation rate of the molecules by the STED beam.4.Results and Discussion4.1.Impact of the Cranial WindowThe chronic hippocampal window used here was originally developed to image pyramidal neurons in the hippocampus by 2-photon microscopy14,15,32 using a 0.8 NA objective. In this case, the specific geometry of the window, a metal cylinder sealed with a coverslip, limited the angle of the marginal rays transmitted through the window [Fig. 2(a)]. Indeed, to reach the hippocampus surface, the implanted cylinder and holder has a height () of 2.23 mm and an inner diameter () of 2.6 mm, which corresponds to a maximum opening angle of 30.2 deg and hence an effective NA of 0.67. Although such an NA can be acceptable for 2-photon imaging, albeit at the expense of reduced spatial resolution (notably axial resolution because of extended excitation PSF), it is prohibitive for STED microscopy. Indeed, beyond the NA limitation, the elimination of the marginal rays by the window design has a dramatic effect on the STED-PSF, rendering it useless, even counterproductive, for improving the STED axial resolution. To further investigate this effect on the STED PSF and the resulting effective fluorescence PSF, we modified the calculation to consider the effect of the cranial window. We introduced an additional amplitude mask in Eq. (2), which models the additional aperture stop at the entrance of the window leading to the clipping of the outer rays after the objectives. The diffraction integral can be expressed as with where is the angle between the optical axis and the marginal ray of the cranial window on the output pupil of the objective.Figures 2(b)–2(f) displays the results of these simulations. In Figs. 2(b) and 2(c), looking at the donut beam, the effect of the reduced NA is easily visible through a clear elongation of the profile. Yet, the presence of the cranial window does not change the geometry of the phase mask (it remains a vortex) and hence the symmetry of the PSF. Therefore, even if suboptimal, this configuration still permits superresolution imaging. In Fig. 2(d), in contrast, the bottle beam is dramatically degraded in the presence of the cranial window. In Fig. 2(e), in the case of the ring phase mask, the outer rays (with 0 phase—blue area in the phase mask) are not passing through the hippocampal window, whereas the inner rays (with phase—red area in the phase mask) remain unaffected. This prevents destructive interference to happen in the focus and hence the formation of the central zero that is required for suppressing the fluorescence in the periphery of the fluorescence PSF while leaving the central region unaffected. In Fig. 2(e), note that by simply adjusting the ring radius on the phase mask, one could effectively retrieve a correct bottle beam profile. Yet, this does not solve the issue of the elongated shape [see panel (d) and (f)] due to the limited effective NA, which results in decreased axial resolution. 4.2.New Cranial Window Design and Experimental ValidationTo retrieve a usable bottle beam and to achieve a substantial STED gain in spatial resolution in all three dimensions, we designed a new cranial window, or hippocampal porthole. Although increasing the radius of the conical window is possible [Fig. 3(a)], retrieving the full NA would require implanting a cylinder with a diameter of 5.1 mm into in the mouse brain, which is prohibitive in terms of the amount of cortical volume that would have to be surgically removed (about of cortex). Instead, we chose to modify the geometry of the window. Using a conical shape [Fig. 3(b), see Supplementary Fig. S1 (3D drawing)] makes it possible to benefit from the full nominal NA of the objective, while minimizing the amount of tissue that needs to be resected to expose the hippocampus, reducing it to about , which is less than one third. We first validated this cranial window geometry ex vivo, by placing gold nanoparticles on a poly-L-lysine coated coverslip, the same that we had used in the cranial window for in vivo imaging, and imaged them either through the cylinder (old window) or conical (new window) porthole without implantation on the head of the animal. This illustrates experimentally the impact of the cranial window design on the PSF of the STED beam. Figure 3 clearly illustrates the effect of the two different cranial window designs on the STED PSF. Beyond the reduction of the NA, the old cylindrical window seriously degrades the shape of the bottle beam, obliterating the central intensity minimum, which is a must for STED microscopy. By contrast, the new conical cranial window design permits the generation of improved donut and bottle beam shapes. With the new design, the NA is limited by the optical design of the objective, and not the geometry of the optical access. 4.3.In Vivo 3D-STED Imaging in the HippocampusTo visualize the gain in resolution in live conditions, fluorescence beads (diameter: ) were attached to the coverslip using poly-L-lysine prior to be grafted into the animal. Imaging the fluorescent beads through the old and new window designs makes it possible to quantify and compare the gain in resolution between them. Figure 4 displays images in and direction of the fluorescent beads visualized through the cranial window. Note that the look-up table is adjusted between images for better visualization. Table 1 reports the axial and lateral resolution obtained experimentally using the two different windows together with the theoretical resolution obtained from numerical simulations. In this table, the spatial resolution is estimated as the full-width at half maximum (FWHM) of the PSF. Beyond the resolution, we quantified the maximum number of counts on the detector as a measure of image brightness (and thus SNR), which is strongly affected by the window geometry. Comparing our simulations with the experimental results, we normalized the number of counts in the simulated image with the value obtained from 2-photon images acquired with the new cranial window (which is expected to yield the highest number of counts). Table 1Spatial resolution (estimated as FWHM of the PSF) and maximum number of counts obtained in 2-photon and STED with the two different cranial window geometries. Mean ± SD from 10 fluorescent beads in 2 different samples prepared from the same batch.
The 2-photon PSFs are slightly improved by the new cylindrical window, yielding a modest but clear improvement in spatial resolution. In contrast, the 3D-STED performance is greatly affected by the type of window design. With the old cylindrical window, the effective PSF is very similar to the 2-photon PSF but with a strongly reduced signal, as expected from the absence of a zero in the bottle beam profile, diminishing the excitation of molecules without yielding of a gain in spatial resolution. In contrast, the new conical window permits a significant constriction of the fluorescent spot, while largely preserving the signal level. Having established this proof of principle, we validated this modified hippocampal window on biological samples by imaging fluorescently labeled neurons in living transgenic mice. Figure 5(a) shows a segment of dendrite in the Stratum radiatum of the CA1 region in the hippocampus of a living mouse. Notably, the fine morphological features, including the hallmark cup-like shapes of spine heads and the ultrathin neck regions, connecting the spine head with the dendrite, can be appreciated with unprecedentedly high image quality in an in vivo setting. Figures 5(b) and 5(c) show a volume rendering of the same segment of dendrite qualitatively illustrating the gain in resolution and anatomical fidelity that can be achieved by our improved approach. Finally, we also quantified neck diameters of the dendritic spines using a semiautomatic software,39 which was specifically designed for morphometric analysis of superresolution images of dendritic spines. The results are summarized in Table 2 and are consistent with the published literature based on electron microscopy or STED imaging in brain slices.40–42 Table 2Average spine morphological parameters measured by 2-photon and 3D-STED microscopy. Mean ± SD from 23 spines collected from 3 mice.
5.ConclusionIn this paper, we propose and validate a modified hippocampal window design, which makes full use of the NA of a long-working distance objective. Although this new design by itself already increases the spatial resolution and optical sectioning of 2-photon microscopy, it is essential for STED microscopy. Notably, it can preserve the bottle beam shape needed for 3D-STED microscopy. We illustrate the benefit of this new cranial window design by visualizing dendritic spines, greatly improving STED image quality, rendering it comparable to the state of the art in brain slice preparations. Combined with state-of-the-art adaptive optics approaches,20,43 this hippocampal window design will pave the way for 3D nanoscale imaging deep within the hippocampus of live mouse. Our new approach improves the achievable spatial resolution for nanoscale imaging of neuroanatomical structures and compartments (e.g., the extracellular space between brain cells44,45), enabling longitudinal investigations into how their dynamics may underpin the ability of neurons and their networks to adapt themselves to ever-changing environmental conditions in health and disease. AcknowledgmentsThis project received funding from the European Union’s Horizon 2020 research and innovation program under the Marie Skłodowska-Curie action (Grant No. 794492), the Fonds AXA pour la Recherche to SB, the Doctoral School for Health and Life Sciences of the University of Bordeaux to JR, the European Research Council (ERC-SyG ENSEMBLE) (Grant No. 951294), Human Frontiers Science Program (Grant No. RGP0036/2020), ERA-NET NEURON (Grant No. ANR-17-NEU3-0005), the Féderation pour la recherche sur le cerveau (FRC), and Agence Nationale de la Recherche (Grant No. ANR-17-CE37-0011) to UVN. We thank the animal facility at IINS for their support. Code, Data, and AvailabilityAll datasets and codes are available from the corresponding authors upon reasonable request. ReferencesC. Sala and M. Segal,
“Dendritic Spines: the locus of structural and functional plasticity,”
Physiol. Rev., 94
(1), 141
–188 https://doi.org/10.1152/physrev.00012.2013 PHREA7 0031-9333
(2014).
Google Scholar
R. Yuste and T. Bonhoeffer,
“Genesis of dendritic spines: insights from ultrastructural and imaging studies,”
Nat. Rev. Neurosci., 5
(1), 24
–34 https://doi.org/10.1038/nrn1300 NRNAAN 1471-003X
(2004).
Google Scholar
T. C. Südhof,
“Neuroligins and neurexins link synaptic function to cognitive disease,”
Nature, 455
(7215), 903
–911 https://doi.org/10.1038/nature07456
(2008).
Google Scholar
K. Svoboda and R. Yasuda,
“Principles of two-photon excitation microscopy and its applications to neuroscience,”
Neuron, 50
(6), 823
–839 https://doi.org/10.1016/j.neuron.2006.05.019 NERNET 0896-6273
(2006).
Google Scholar
Z. Mainen et al.,
“Two-photon imaging in living brain slices,”
Methods, 18
(2), 231
–239 https://doi.org/10.1006/meth.1999.0776 MTHDE9 1046-2023
(1999).
Google Scholar
G. C. Ellis-Davies,
“Two-photon microscopy for chemical neuroscience,”
ACS Chem. Neurosci., 2
(4), 185
–197 https://doi.org/10.1021/cn100111a
(2011).
Google Scholar
J. N. Kerr and W. Denk,
“Imaging in vivo: watching the brain in action,”
Nat. Rev. Neurosci., 9
(3), 195
–205 https://doi.org/10.1038/nrn2338 NRNAAN 1471-003X
(2008).
Google Scholar
M. J. Levene et al.,
“In vivo multiphoton microscopy of deep brain tissue,”
J. Neurophysiol., 91
(4), 1908
–1912 https://doi.org/10.1152/jn.01007.2003 JONEA4 0022-3077
(2004).
Google Scholar
A. L. A. Mascaro, L. Sacconi and F. S. Pavone,
“Multi-photon nanosurgery in live brain,”
Front. Neuroenergetics, 2 21 https://doi.org/10.3389/fnene.2010.0002
(2010).
Google Scholar
A. Holtmaat and K. Svoboda,
“Experience-dependent structural synaptic plasticity in the mammalian brain,”
Nat. Rev. Neurosci., 10
(9), 647
–658 https://doi.org/10.1038/nrn2699 NRNAAN 1471-003X
(2009).
Google Scholar
J. T. Trachtenberg et al.,
“Long-term in vivo imaging of experience-dependent synaptic plasticity in adult cortex,”
Nature, 420
(6917), 788
–794 https://doi.org/10.1038/nature01273
(2002).
Google Scholar
S. K. Kim, K. Eto and J. Nabekura,
“Synaptic structure and function in the mouse somatosensory cortex during chronic pain: in vivo two-photon imaging,”
Neural Plast., 2012 640259 https://doi.org/10.1155/2012/640259
(2012).
Google Scholar
S. El-Boustani et al.,
“Locally coordinated synaptic plasticity of visual cortex neurons in vivo,”
Science, 360
(6395), 1349
–1354 https://doi.org/10.1126/science.aao0862 SCIEAS 0036-8075
(2018).
Google Scholar
A. Mizrahi et al.,
“High-resolution in vivo imaging of hippocampal dendrites and spines,”
J. Neurosci., 24
(13), 3147
–3151 https://doi.org/10.1523/JNEUROSCI.5218-03.2004 JNRSDS 0270-6474
(2004).
Google Scholar
L. Gu et al.,
“Long-term in vivo imaging of dendritic spines in the hippocampus reveals structural plasticity,”
J. Neurosci., 34
(42), 13948
–13953 https://doi.org/10.1523/JNEUROSCI.1464-14.2014 JNRSDS 0270-6474
(2014).
Google Scholar
A. Attardo, J. E. Fitzgerald and M. J. Schnitzer,
“Impermanence of dendritic spines in live adult CA1 hippocampus,”
Nature, 523
(7562), 592
–596 https://doi.org/10.1038/nature14467
(2015).
Google Scholar
S. W. Hell,
“Far-field optical nanoscopy,”
Science, 316
(5828), 1153
–1158 https://doi.org/10.1126/science.1137395 SCIEAS 0036-8075
(2007).
Google Scholar
S. Berning et al.,
“Nanoscopy in a living mouse brain,”
Science, 335
(6068), 551 https://doi.org/10.1126/science.1215369
(2012).
Google Scholar
H. Steffens, W. Wegner and K. I. Willig,
“In vivo STED microscopy: a roadmap to nanoscale imaging in the living mouse,”
Methods, 174 42
–48 https://doi.org/10.1016/j.ymeth.2019.05.020 MTHDE9 1046-2023
(2020).
Google Scholar
M. G. M. Velasco et al.,
“3D super-resolution deep-tissue imaging in living mice,”
Optica, 8
(4), 442
–450 https://doi.org/10.1364/OPTICA.416841
(2021).
Google Scholar
K. I. Willig,
“In vivo super-resolution of the brain–how to visualize the hidden nanoplasticity,”
iScience, 25 104961 https://doi.org/10.1016/j.isci.2022.104961
(2022).
Google Scholar
M. Fuhrmann et al.,
“Super-resolution microscopy opens new doors to life at the nanoscale,”
J. Neurosci., 42
(45), 8488
–8497 https://doi.org/10.1523/JNEUROSCI.1125-22.2022 JNRSDS 0270-6474
(2022).
Google Scholar
T. Pfeiffer et al.,
“Chronic 2P-STED imaging reveals high turnover of dendritic spines in the hippocampus in vivo,”
eLife, 7 e34700 https://doi.org/10.7554/eLife.34700
(2018).
Google Scholar
C. V. Middendorff et al.,
“Isotropic 3D nanoscopy based on single emitter switching,”
Opt. Express, 16
(25), 20774
–20788 https://doi.org/10.1364/OE.16.020774 OPEXFF 1094-4087
(2008).
Google Scholar
D. Wildanger et al.,
“A compact STED microscope providing 3D nanoscale resolution,”
J. Microsc., 236
(1), 35
–43 https://doi.org/10.1111/j.1365-2818.2009.03188.x JMICAR 0022-2720
(2009).
Google Scholar
M. O. Lenz et al.,
“3-D stimulated emission depletion microscopy with programmable aberration correction,”
J. Biophotonics, 7
(1–2), 29
–36 https://doi.org/10.1002/jbio.201300041
(2014).
Google Scholar
S. Bancelin et al.,
“Aberration correction in stimulated emission depletion microscopy to increase imaging depth in living brain tissue,”
Neurophotonics, 8
(3), 035001 https://doi.org/10.1117/1.NPh.8.3.035001
(2021).
Google Scholar
J. Heine et al.,
“Three dimensional live-cell sted microscopy at increased depth using a water immersion objective,”
Rev. Sci. Instrum., 89
(5), 053701 https://doi.org/10.1063/1.5020249 RSINAK 0034-6748
(2018).
Google Scholar
S. W. Cramer et al.,
“Through the looking glass: a review of cranial window technology for optical access to the brain,”
J. Neurosci. Methods, 354 109100 https://doi.org/10.1016/j.jneumeth.2021.109100 JNMEDT 0165-0270
(2021).
Google Scholar
P. Bethge et al.,
“Two-photon excitation STED microscopy in two colors in acute brain slices,”
Biophys. J., 104
(4), 778
–785 https://doi.org/10.1016/j.bpj.2012.12.054 BIOJAU 0006-3495
(2013).
Google Scholar
G. Feng et al.,
“Imaging neuronal subsets in transgenic mice expressing multiple spectral variants of GFP,”
Neuron, 28
(1), 41
–51 https://doi.org/10.1016/S0896-6273(00)00084-2 NERNET 0896-6273
(2000).
Google Scholar
D. A. Dombeck et al.,
“Functional imaging of hippocampal place cells at cellular resolution during virtual navigation,”
Nat. Neurosci., 13
(11), 1433
–1440 https://doi.org/10.1038/nn.2648 NANEFN 1097-6256
(2010).
Google Scholar
E. Wolf,
“Electromagnetic diffraction in optical systems–I. An integral representation of the image field,”
Proc. R. Soc. Lond. Ser. A. Math. Phys. Sci., 253
(1274), 349
–357 https://doi.org/10.1098/rspa.1959.0199
(1959).
Google Scholar
B. Richards and E. Wolf,
“Electromagnetic diffraction in optical systems-II. Structure of the image field in an aplanatic system,”
Proc. R. Soc. Lond. Ser. A. Math. Phys. Sci., 253
(1274), 358
–379 https://doi.org/10.1098/rspa.1959.0200
(1959).
Google Scholar
M. Gu, Advanced Optical imaging Theory, Springer Science & Business Media(
(2000). Google Scholar
P. Török et al.,
“Electromagnetic diffraction of light focused through a planar interface between materials of mismatched refractive indices: an integral representation,”
JOSA A, 12
(2), 325
–332 https://doi.org/10.1364/JOSAA.12.000325
(1995).
Google Scholar
P. Török and P. Varga,
“Electromagnetic diffraction of light focused through a stratified medium,”
Appl. Opt., 36
(11), 2305
–2312 https://doi.org/10.1364/AO.36.002305 APOPAI 0003-6935
(1997).
Google Scholar
K. Willig et al.,
“STED microscopy resolves nanoparticle assemblies,”
New J. Phys., 8
(6), 106 https://doi.org/10.1088/1367-2630/8/6/106 NJOPFM 1367-2630
(2006).
Google Scholar
F. Levet et al.,
“SpineJ: a software tool for quantitative analysis of nanoscale spine morphology,”
Methods, 174 49
–55 https://doi.org/10.1016/j.ymeth.2020.01.020 MTHDE9 1046-2023
(2020).
Google Scholar
K. Harris and J. Stevens,
“Dendritic spines of CA 1 pyramidal cells in the rat hippocampus: serial electron microscopy with reference to their biophysical characteristics,”
J. Neurosci., 9
(8), 2982
–2997 https://doi.org/10.1523/JNEUROSCI.09-08-02982.1989 JNNUEF
(2018).
Google Scholar
J. I. Arellano et al.,
“Ultrastructure of dendritic spines: correlation between synaptic and spine morphologies,”
Front. Neurosci., 1
(1), 131
–143 https://doi.org/10.3389/neuro.01.1.1.010.2007 1662-453X
(2007).
Google Scholar
J. Tønnesen et al.,
“Spine neck plasticity regulates compartmentalization of synapses,”
Nat. Neurosci., 17
(5), 678
–685 https://doi.org/10.1038/nn.3682 NANEFN 1097-6256
(2014).
Google Scholar
T. J. Gould et al.,
“Adaptive optics enables 3D STED microscopy in aberrating specimens,”
Opt. Express, 20
(19), 20998
–21009 https://doi.org/10.1364/OE.20.020998 OPEXFF 1094-4087
(2012).
Google Scholar
J. Tønnesen, V. K. Inavalli and U. V. Nägerl,
“Super-resolution imaging of the extracellular space in living brain tissue,”
Cell, 172
(5), 1108
–1121.e15 https://doi.org/10.1016/j.cell.2018.02.007 CELLB5 0092-8674
(2018).
Google Scholar
S. Hrabetova et al.,
“Unveiling the extracellular space of the brain: from super-resolved microstructure to in vivo function,”
J. Neurosci., 38
(44), 9355
–9363 https://doi.org/10.1523/JNEUROSCI.1664-18.2018 JNRSDS 0270-6474
(2018).
Google Scholar
BiographyU. Valentin Nägerl is a professor of neuroscience and bioimaging at the University of Bordeaux, where he leads a research group and is in charge of the masters program in bio-photonics and neurotechnology. He studied physics and pre-clinical medicine in Göttingen, got his PhD in neuroscience from UCLA in 2000, and worked as a postdoc at the Max Planck Institute of Neurobiology. His research focuses on the development and application of super-resolution imaging techniques to study the structure and function of the brain’s micro-architecture including its extracellular spaces. |
CITATIONS
Cited by 2 scholarly publications.
Stimulated emission depletion microscopy
Windows
Spine
Point spread functions
Cranial windows
Brain
Spatial resolution