Open Access
7 March 2023 High-speed hyperspectral imaging enabled by compressed sensing in time domain
Author Affiliations +
Abstract

Hyperspectral imaging (HSI) is a powerful tool widely used for various scientific and industrial applications due to its ability to provide rich spatiospectral information. However, in exchange for multiplex spectral information, its image acquisition rate is lower than that of conventional imaging, with up to a few colors. In particular, HSI in the infrared region and using nonlinear optical processes is impractically slow because the three-dimensional (3D) data cube must be scanned in a point-by-point manner. In this study, we demonstrate a framework to improve the spectral image acquisition rate of HSI by integrating time-domain HSI and compressed sensing. Specifically, we simulated broadband coherent Raman imaging at a record high frame rate of 25 frames per second (fps) with 100 pixels × 100 pixels, which is 10 × faster than that of previous work, based on an experimentally feasible sampling scheme utilizing 3D Lissajous scanning.

1.

Introduction

Hyperspectral imaging (HSI) is a powerful tool widely used in a diverse range of applications, such as remote sensing,1,2 food testing,3 pharmaceutical testing,4 forensic testing,5 and disease diagnosis,6 as it can acquire spatially resolved spectral information. In HSI, hyperspectral images are acquired by obtaining the light intensities in the spatiospectral three-dimensional (3D) (x,y,λ) data cube via various methods, such as whisk broom sensing (point-scanning to record spectral information of each pixel with a diffraction grating and a linear sensor array),7 push broom sensing [line-scanning to record a one-dimensional (1D) spectral image with a two-dimensional (2D) camera],8 staring sensing (spectral filtering of incoming light to record the images of each spectral band with a 2D camera),9 snapshot spectral imaging (a nonscanning method to record the remapped 3D data cube with a 2D camera),10 and compressed sensing (CS)-based coded aperture snapshot spectral imaging (CASSI)11,12 as shown in Figs. 1(a)1(c). Among them, the staring method is most widely used in modern HSI applications because it is compatible with on-the-fly spectral imaging, as its image acquisition is easily performed with a 2D camera after spectral filtering by a tunable filter.

Fig. 1

Data acquisition of a 3D data cube in HSI. (a) Various scanning methods to obtain a 3D data cube in HSI. The pixels measured during a detector integration period are depicted for each scanning method. (b) Snapshot spectral imaging. (c) CASSI. (d) Data acquisition of CS-powered HSI. The data points in the 3D data cube are partially sampled and then processed to reconstruct the complete data set.

APN_2_2_026008_f001.png

However, the staring method often suffers from low light transmittance and therefore limited signal-to-noise ratio (SNR) especially in the infrared (IR) region due to the lack of sensitive image sensors. Also the wide-field illumination of the staring method is an impediment to nonlinear optical measurements, which require high optical intensity at the sample to produce a detectable signal. Similarly, CASSI cannot be applied to nonlinear HSI due to its wide-field illumination. To overcome these issues, it has been demonstrated that scanning in the spatiotemporal space (x,y,τ), or time-domain HSI, provides a higher SNR by virtue of its multiplex advantage (also known as Fellgett’s advantage) compared to direct measurements in the spectral domain. Unfortunately, the major drawback of time-domain HSI is its low image acquisition rate, primarily due to slow optical scanners for multidimensional spectral image acquisition. Even with high-speed optical scanning using a resonant scanner, only up to 2.4 frames per second (fps) with a pixel resolution of 100  pixels×100  pixels has been realized.13 To boost the image acquisition speed, one possible approach is to combine time-domain HSI with CS14,15 [Fig. 1(b)], which provides a technique to recover a complete data set from fewer measurements than what is required by the Nyquist–Shannon sampling theorem based on two assumptions: (i) the signal from the target object is sparse in a suitable domain and (ii) the measurement process is incoherent; the sampling intervals along the τ axis are randomized in the case of Fourier-transformation-based measurements like time-domain HSI. Although CS has been demonstrated for time-domain HSI, the methods implemented in the previous demonstrations are not applicable to high-speed hyperspectral image acquisition because the requisite sampling randomization was implemented during postmeasurement processing16 or was paired with a lower camera frame rate.17

In this paper, we report a CS-powered method to achieve high-speed time-domain HSI. Specifically, we used broadband (200 to 1600  cm1) Fourier-transform coherent anti-Stokes Raman scattering (FT-CARS), a type of nonlinear Raman process,13,18,19 as a platform to evaluate this method. We sampled time-domain interferograms sparsely by utilizing the 3D Lissajous scanning method20 to boost the hyperspectral image acquisition rate and then reconstructed hyperspectral images by solving an inverse problem regularized with spatiospectral total variation (SSTV).21 We demonstrated hyperspectral image acquisition at a frame rate of 25 fps with a pixel resolution of 100  pixels×100  pixels under experimentally feasible conditions, which is 10 times higher than that of the previous record.13 We compared the original sinusoidal Lissajous scanning and the triangular Lissajous scanning for CS-based high-speed time-domain HSI in terms of noise robustness and achievable compression ratios, showing that Raman hyperspectral images were reconstructed with reasonable quality in both methods. Because the present scheme is applicable to many realistic Raman or HSI methods and these simulations are based on existing experimental demonstrations that used commercially available equipment, our method offers a powerful platform for the video-rate visualization of rapid chemical processes in various systems, such as inhomogeneous chemical reactions and living cells.

2.

Methods

Figure 2(a) schematically shows the optical setup of our simulated CS-based FT-CARS imaging system. The light source is a femtosecond laser with a repetition rate of 80 MHz. In FT-CARS measurements, molecular vibrations are coherently excited by a pump pulse and interrogated by a time-delayed probe pulse.22 Pump–probe pulse pairs are generated by a Michaelson interferometer, where the optical path length of one of the arms is modulated by a resonant scanner. The incident beams are then spatially scanned by the two galvanometric scanners for interrogating different spatial points of the sample. A long-pass and short-pass filter pair, placed before and after the sample, respectively, isolates the blueshifted CARS signals. Just as in previously demonstrated FT-CARS measurements,22 the CARS signal is acquired as a function of the pump–probe delay, which is Fourier-transformed to obtain the Raman spectrum as a function of Raman shift or wavenumber.

Fig. 2

CS-based FT-CARS imaging. (a) Schematic of the simulated experimental setup. AL, achromatic lens; APD, avalanche photodiode; CoM, concave mirror; L, lens; LPF, long-pass filter; P, polarizer; PBS, polarizing beam splitter; RS, resonant scanner; S, sample; Sc, scanner; SPF, short-pass filter; and λ/4, quarter-wave plate. (b), (c) Conceptual illustration of sinusoidal (b) and triangular (c) Lissajous scanning trajectories in 3D space spanned by positions (x,y) and optical delay τ. Typical sampling patterns at one spatial point are shown in the caption bubbles. (d), (e) Distributions of the number of sampled points with sinusoidal scanning (d) and triangular scanning (e) for  xy scanning. The upper bound is set at 300 for both images.

APN_2_2_026008_f002.png

In the present scheme, the (x,y,τ) data cube was scanned in a 3D Lissajous trajectory20 such that the sampling interval along the τ axis became pseudorandom at each spatial point [Fig. 2(b)]. To this end, there are several options for scanning functions to generate the 3D Lissajous scanning trajectory, such as triangular and sinusoidal functions, especially for the xy scanning. Each of them has advantages and disadvantages in the context of CS recovery. As discussed in the previous research,20 triangular functions are more advantageous than sinusoidal functions in terms of the uniformity of the number of sampled points in the xy plane, as shown in Fig. 2(c). On the other hand, sinusoidal functions realize shorter pixel dwell time than triangular functions because sinusoidally oscillating scanners, such as a resonant scanner and a microelectrochemical system scanner, can operate at higher frequencies. Because shorter pixel dwell time leads to a more randomized sampling pattern along the τ axis at each pixel, as shown in the caption of Fig. 1(b), more reliable CS recovery is expected.14 We compared the performances of triangular and sinusoidal scanning functions in the following numerical simulations.

The procedure to reconstruct the hyperspectral image from the sparsely sampled data is introduced as follows. First, we define Nx,Ny, and Nb as the dimensions of the hyperspectral image, N=NxNyNb as the full size of data points in the spectral domain, and M as the total number of sampled points in the time domain. Let u=[u1,1T,,uNx,NyT]TCN be the hyperspectral image made by stacking the spectrum of each spatial position on top of one another and f=[f1,1T,,fNx,NyT]TRM be a stack of coarsely measured time-domain interferograms at each spatial position. A hyperspectral image u was reconstructed from the coarse time-domain signals f obtained with Lissajous scanning by solving the following optimization problem with a regularization term called the anisotropic SSTV:21

Eq. (1)

u^=argminuCN{Re[Wu]f22+λ(DxDbu1+DyDbu1)},
where WCM×N is a measurement matrix and λR is a hyperparameter. Dx, Dy, and Db are differential operators with respect to the x axis, the y axis, and the frequency axis, respectively, which act on each spectrum up,qCNb(p=1,,Nx,q=1,,Ny) as
Dxup,q={up+1,qup,q(if  pNx)0(if  p=Nx),
Dyup,q={up,q+1up,q(if  qNy)0(if  q=Ny),
(Dbup,q)b={(up,q)b+1(up,q)b(if  bNb)0(if  b=Nb),
where (up,q)b(b=1,,Nb) represents the bth band of the spectra up,q. W is a block-diagonal matrix containing inverse nonuniform discrete Fourier transform (NDFT) matrices for each pixel. The number of measurement points at each pixel is made uniform at 300 by picking up measurement points randomly or padding with zeros so that each diagonal element of W has the same shape, which significantly accelerates the multiplication of W and u. The value of hyperparameter λ was determined so that the value of the root-mean-squared error (RMSE) between the ground-truth time-domain signals and the pixel-wise inverse Fourier transform of the estimated spectral image is minimized (Fig. 3). It is important to note that the optimal value of λ can be estimated by cross-validation even if we do not know the ground truth. Equation (1) was solved with the primal–dual splitting (PDS) algorithm.23,24 The PDS algorithm can solve optimization problems in the following form:

Eq. (2)

minu{f(u)+g(u)+h(Gu)},
where G  is a matrix and f,  g, and h are the convex functions. f is differentiable, whereas g and h do not need to be differentiable. The algorithm is given by

Eq. (3)

{u(k+1)=proxγ1g{u(k)γ1[f(u(k))+GTv(k)]}v(k+1)=proxγ2h*{v(k)+γ2G[2u(k+1)u(k)]},
where γ1,γ2>0 are step sizes, a proximity operator of a function f is defined as proxγf(x)=argminy[f(y)+(1/2γ)xy22], and a proximity operator of a conjugate function of f is defined as proxγf*(x)=xγproxf/γ(x/γ). Under mild conditions on f,  g,  h, and G, the sequence {u(k)} converges to the optimal solution of Eq. (2) with arbitrarily chosen u(0)and v(0). By letting f(u)=Re[Wu]f22, g=0, G=DDb, and h(v)=λv1 where D=[DxT  DyT]T, we obtain the calculation steps of the PDS algorithm to solve Eq. (1),

Eq. (4)

{u(k+1)=u(k)γ1[WH(Re[Wu(k)]f)+DbTDTv(k)](v)(k)=v(k)+γ2DDb[2u(k+1)u(k)]v(k+1)=(v)(k)γ2Sλ/γ2[(v)(k)/γ2],
where Sγ(a)=proxγ·1(a)=(a/|a|)max(|a|γ,0) is a soft-thresholding function which acts on a vector component-wise.

Fig. 3

Selection of the hyperparameter values. RMSE values as a function of λ are shown. The measurement duration is 40 ms. Dashed lines represent the optimal values of λ.

APN_2_2_026008_f003.png

3.

Results

As a proof-of-concept demonstration, we simulated hyperspectral image reconstruction with a simple artificial hyperspectral image, shown in Fig. 4(a). We first determined the sinusoidal Lissajous scanning trajectory by three sinusoidal functions with scanning frequencies of fx=12,705  Hz, fy=12,505  Hz, and fτ=12,520  Hz, and the triangular Lissajous trajectory by two triangular functions with fx=1005  Hz and fy=1060  Hz and a sinusoidal function with fτ=12,520  Hz, with a measurement duration of 40 ms so that the trajectory covered a large number of spatial positions and never repeated itself and the restricted isometry constant of the measurement matrix was small. This measurement duration was 10 times shorter than the corresponding raster scan measurement. We assumed that one kind of chemical with five Raman vibrational modes was spread in a droplet-like concentration distribution shown in Fig. 4(a). Then we sampled corresponding time-domain interferograms in the generated Lissajous trajectory. Figures 4(b)4(d) show the results of the hyperspectral image reconstruction with and without CS. Simple pixel-wise NDFT of undersampled data failed to recover the spectra due to aliasing, as shown in Fig. 4(b), whereas five input peaks were recovered in the spectral image reconstructed via CS [Figs. 4(c) and 4(d)].

Fig. 4

Numerical simulation of recovering undersampled data. (a) Assumed spectrum of a chemical and its concentration map. (b) Typical spectrum and intensity map at 1000  cm1 of sparsely sampled data obtained by pixel-wise NDFT without CS. (c), (d) Typical spectra and intensity maps at 1000  cm1 of the hyperspectral images reconstructed via CS from time-domain signals coarsely sampled with (c) sinusoidal Lissajous scanning (d) and triangular Lissajous scanning. The arrows in (b)–(d) indicate the points whose spectra are displayed.

APN_2_2_026008_f004.png

To quantitatively evaluate the reconstruction performance, we reconstructed spectral images from the sparsely sampled time-domain interferograms with different noise levels, different compression ratios, and different scanning schemes (faster sinusoidal and slower triangular). The reconstruction performances were evaluated by the RMSE between the ground-truth time-domain interferograms and the pixel-wise inverse Fourier transform of the estimated spectral image. First, we investigated the measurement-duration dependence of the reconstruction performance in the sinusoidal and triangular scanning schemes [Fig. 5(a)]. To simulate the reconstruction with different measurement durations, the measurement duration was simply changed with the same scanning frequencies in the sinusoidal case, whereas the scanning frequencies were modified so that the number of samples at each pixel became more uniform in the triangular case. These simulation conditions are consistent with the realistic experimental situation, where the frequency of the resonant scanner cannot be significantly changed, while that of the galvanometric scanner can flexibly be changed within a certain frequency range. As seen in Fig. 5(a), the sinusoidal scanning provides lower RMSE values with different measurement durations than that of the triangular scanning, presumably because the sinusoidal Lissajous trajectory has more randomized sampling intervals along the τ axis at each pixel. Figures 5(b) and 5(c) show typical intensity maps at 1000  cm1 and typical spectra for measurement durations of 30 ms with sinusoidal Lissajous scanning and triangular Lissajous scanning, respectively. Next, we studied the noise dependence of the reconstruction performance by adding Gaussian noise to the input time-domain interferograms [Fig. 5(d)]. The noise amplitude was varied from zero to one with respect to the amplitude of the 1000  cm1 mode of the sample. Although there are slight differences in the performances of these two scanning functions, both methods work well, as shown in Figs. 5(b), 5(c), 5(e), and 5(f).

Fig. 5

Performance of CS-powered time-domain HSI with different scanning functions. (a) Performance of CS-powered time-domain HSI with different compression ratios. The top axis represents the measurement time normalized by Traster, the measurement time in the raster-scan method. (b), (c) Intensity maps at 1000  cm1 and typical spectra with measurement durations of 30 ms with sinusoidal Lissajous scanning and triangular Lissajous scanning, respectively. (d) Performance of CS-powered time-domain HSI with different values of noise amplitudes and a measurement duration of 40 ms. (e), (f) Typical intensity maps at 1000  cm1 and typical spectra with a noise amplitude of 0.5 with sinusoidal Lissajous scanning and triangular Lissajous scanning, respectively. Arrows in (b), (c), (e), and (f) indicate the points whose spectra are displayed.

APN_2_2_026008_f005.png

To further evaluate the performance of our method in practical applications, we also demonstrated the reconstruction of a biological hyperspectral image in a semiexperimental manner using a Raman spectral image of a Euglena gracilis cell taken by a spontaneous Raman microscope (Renishaw inVia). A 31  pixel×33pixel Raman hyperspectral image of a wild-type E. gracilis cell was obtained using 74 mW of 532 nm excitation, a 50× objective, and a per-pixel measurement duration of 300 ms. The image was denoised by truncated singular value decomposition using the top-10 components, and then spectral background was removed using the rolling-ball filter method.25 We generated the time-domain interferograms by inverse Fourier transforming the spectrum at each pixel after resizing it to 100  pixels×100  pixels and applying a window function. The sinusoidal Lissajous sampling proposed above was used with a measurement duration of 60 ms. Figures 6(a)6(j) show typical intensity maps and spectra of the reconstructed spectral image and the Fourier transform of the generated full-size time-domain interferograms. Although the spatial resolution is degraded due to the use of total variation regularization, the same molecular distributions between the reconstructed [Figs. 6(a), 6(c), and 6(e)] and ground-truth [Figs. 6(b), 6(d), and 6(f)] spectral images and peak distributions among their corresponding spectra [Figs. 6(g)6(i)] are evident. Figure 6(k) shows the performance of CS-based time-domain HSI for different measurement durations.

Fig. 6

Recovery of a spectral image of an E. gracilis cell by CS. (a), (c), (e) Intensity maps at 1000, 1300, and 1440  cm1 of hyperspectral images reconstructed via CS, respectively. (b), (d), (f) Intensity maps at 1000, 1300, and 1440  cm1 of hyperspectral images obtained by Fourier transform of generated time-domain interferograms, respectively. (g), (i) CS-reconstructed spectra at the points indicated by arrows in (a) and (c), respectively. (h), (j) Fourier transform of the generated time-domain interferograms at the points indicated by arrows in (b) and (d), respectively. (k) Performance of CS-based time-domain HSI for different measurement durations.

APN_2_2_026008_f006.png

4.

Discussion

It is worthwhile to compare our scheme with other CS-based HSI methods that operate in the frequency domain.20,26 To date, the frequency-domain approach has used random masks26 or Lissajous scanning20 to randomly sample frequency or spatial components; these reconstructions are only reliable when the spectra are nonsparse because CS works well under the condition that signal sampling occurs in a nonsparse domain.27 On the other hand, in our time-domain approach, spectra composed of sharp peaks are preferred because the energy of such sharp peaks is delocalized in the time domain. Thus FT-CARS spectroscopy is a suitable platform for CS because its spectra have a sparse nature originating from the narrow molecular lines spread in a broad spectral range and the absence of background signals such as fluorescence.

In summary, we have numerically demonstrated CS-based time-domain HSI with a spectral image acquisition rate of 10× higher than that of conventional raster scanning. By combining the Lissajous-scanning–based sampling method and spectral image reconstruction by SSTV, reliable Raman spectral image reconstruction was realized for a simple synthetic bead image and a cell image taken by a spontaneous Raman microscope. We compared different scanning methods, faster sinusoidal scanning, and slower triangular scanning and showed that both schemes are feasible for acquiring Raman hyperspectral images at a video rate (with a measurement duration of 30 ms). The present method requires only slight modifications to the existing FT-CARS imaging setup and is extendable to other time-domain HSI methods, such as FT-IR and FT-two-photon excitation.28

Acknowledgments

This work was supported by JST PRESTO (Grant No. JPMJPR1878), JST FOREST (Grant No. 21470594), JSPS Grant-in-Aid for Young Scientists (20K15227), Grant-in-Aid for Scientific Research (B) (Grant No. 22538379), Grant-in-Aid for JSPS Fellows (Grant No. 21J11484), JSPS Core-to-Core Program, White Rock Foundation, Nakatani Foundation, and Ogasawara Foundation for the Promotion of Science and Engineering. The authors declare that they have no conflicts of interest to disclose.

References

1. 

F. D. van der Meer et al., “Multi- and hyperspectral geologic remote sensing: a review,” Int. J. Appl. Earth Obs. Geoinf., 14 (1), 112 –128 https://doi.org/10.1016/j.jag.2011.08.002 (2012). Google Scholar

2. 

B. Lu et al., “Recent advances of hyperspectral imaging technology and applications in agriculture,” Remote Sens., 12 (16), 2659 https://doi.org/10.3390/rs12162659 RSEND3 (2020). Google Scholar

3. 

H. Huang, L. Liu and M. Ngadi, “Recent developments in hyperspectral imaging for assessment of food quality and safety,” Sensors, 14 (4), 7248 –7276 https://doi.org/10.3390/s140407248 SNSRES 0746-9462 (2014). Google Scholar

4. 

J. M. Amigo, “Practical issues of hyperspectral imaging analysis of solid dosage forms,” Anal. Bioanal. Chem., 398 (1), 93 –109 https://doi.org/10.1007/s00216-010-3828-z (2010). Google Scholar

5. 

G. J. Edelman et al., “Hyperspectral imaging for non-contact analysis of forensic traces,” Forensic Sci. Int., 223 (1–3), 28 –39 https://doi.org/10.1016/j.forsciint.2012.09.012 FSINDR 0379-0738 (2012). Google Scholar

6. 

G. Lu and B. Fei, “Medical hyperspectral imaging: a review,” J. Biomed. Opt., 19 (1), 010901 https://doi.org/10.1117/1.JBO.19.1.010901 JBOPFO 1083-3668 (2014). Google Scholar

7. 

R. O. Green et al., “Imaging spectroscopy and the airborne visible/infrared imaging spectrometer (AVIRIS),” Remote Sens. Environ., 65 (3), 227 –248 https://doi.org/10.1016/S0034-4257(98)00064-9 RSEEA7 0034-4257 (1998). Google Scholar

8. 

T. Cocks et al., “The HyMap TM airborne hyperspectral sensor: the system, calibration and performance,” in Proc. 1st EARSeL Workshop on Imaging Spectrosc., 37 –42 (1998). Google Scholar

9. 

N. Gat, “Imaging spectroscopy using tunable filters: a review,” in AeroSense 2000, 50 –64 (2000). Google Scholar

10. 

N. Hagen, “Snapshot advantage: a review of the light collection improvement for parallel high-dimensional measurement systems,” Opt. Eng., 51 (11), 111702 https://doi.org/10.1117/1.OE.51.11.111702 (2012). Google Scholar

11. 

A. A. Wagadarikar et al., “Video rate spectral imaging using a coded aperture snapshot spectral imager,” Opt. Express, 17 (8), 6368 https://doi.org/10.1364/OE.17.006368 OPEXFF 1094-4087 (2009). Google Scholar

12. 

G. R. Arce et al., “Compressive coded aperture spectral imaging: an introduction,” IEEE Signal Process. Mag., 31 (1), 105 –115 https://doi.org/10.1109/MSP.2013.2278763 ISPRE6 1053-5888 (2014). Google Scholar

13. 

R. Kinegawa et al., “High-speed broadband Fourier-transform coherent anti-Stokes Raman scattering spectral microscopy,” J Raman Spectrosc., 50 (8), 1141 –1146 https://doi.org/10.1002/jrs.5630 (2019). Google Scholar

14. 

D. L. Donoho, “Compressed sensing,” IEEE Trans. Inf. Theory, 52 (4), 1289 –1306 https://doi.org/10.1109/TIT.2006.871582 IETTAW 0018-9448 (2006). Google Scholar

15. 

E. J. Candes, J. Romberg and T. Tao, “Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information,” IEEE Trans. Inf. Theory, 52 (2), 489 –509 https://doi.org/10.1109/TIT.2005.862083 IETTAW 0018-9448 (2006). Google Scholar

16. 

B. Kästner et al., “Compressed sensing FTIR nano-spectroscopy and nano-imaging,” Opt. Express, 26 (14), 18115 https://doi.org/10.1364/OE.26.018115 OPEXFF 1094-4087 (2018). Google Scholar

17. 

J. M. Charsley et al., “Compressive hyperspectral imaging in the molecular fingerprint band,” Opt. Express, 30 (10), 17340 https://doi.org/10.1364/OE.451380 OPEXFF 1094-4087 (2022). Google Scholar

18. 

K. Hiramatsu et al., “High-throughput label-free molecular fingerprinting flow cytometry,” Sci. Adv., 5 (1), eaau0241 https://doi.org/10.1126/sciadv.aau0241 STAMCV 1468-6996 (2019). Google Scholar

19. 

J. Gala de Pablo et al., “High-throughput Raman flow cytometry and beyond,” Acc. Chem. Res., 54 (9), 2132 –2143 https://doi.org/10.1021/acs.accounts.1c00001 ACHRE4 0001-4842 (2021). Google Scholar

20. 

H. Lin et al., “Spectroscopic stimulated Raman scattering imaging of highly dynamic specimens through matrix completion,” Light Sci. Appl., 7 (5), 17179 –17179 https://doi.org/10.1038/lsa.2017.179 (2018). Google Scholar

21. 

H. K. Aggarwal and A. Majumdar, “Hyperspectral image denoising using spatio-spectral total variation,” IEEE Geosci. Remote Sens. Lett., 13 442 –446 https://doi.org/10.1109/LGRS.2016.2518218 (2016). Google Scholar

22. 

J. P. Ogilvie et al., “Fourier-transform coherent anti-Stokes Raman scattering microscopy,” Opt. Lett., 31 (4), 480 https://doi.org/10.1364/OL.31.000480 OPLEDP 0146-9592 (2006). Google Scholar

23. 

L. Condat, “A primal–dual splitting method for convex optimization involving Lipschitzian, proximable and linear composite terms,” J. Optim. Theory Appl., 158 (2), 460 –479 https://doi.org/10.1007/s10957-012-0245-9 JOTABN 0022-3239 (2013). Google Scholar

24. 

B. C. Vũ, “A splitting algorithm for dual monotone inclusions involving cocoercive operators,” Adv. Comput. Math., 38 (3), 667 –681 https://doi.org/10.1007/s10444-011-9254-8 ACMHEX 1019-7168 (2013). Google Scholar

25. 

T. M. James et al., “Automated quantitative spectroscopic analysis combining background subtraction, cosmic ray removal, and peak fitting,” Appl. Spectrosc., 67 (8), 949 –959 https://doi.org/10.1366/12-06766 APSPA4 0003-7028 (2013). Google Scholar

26. 

F. Soldevila et al., “Fast compressive Raman bio-imaging via matrix completion,” Optica, 6 (3), 341 https://doi.org/10.1364/OPTICA.6.000341 (2019). Google Scholar

27. 

E. J. Candes and M. B. Wakin, “An introduction to compressive sampling,” IEEE Signal Process. Mag., 25 (2), 21 –30 https://doi.org/10.1109/MSP.2007.914731 ISPRE6 1053-5888 (2008). Google Scholar

28. 

M. Lindley et al., “Ultrafast simultaneous Raman-fluorescence spectroscopy,” Anal. Chem., 91 (24), 15563 –15569 https://doi.org/10.1021/acs.analchem.9b03563 ANCHAM 0003-2700 (2019). Google Scholar

Biography

Shigekazu Takizawa received his MS degree in chemistry in 2020 from the University of Tokyo. He is a PhD candidate in the Chemistry Department of the University of Tokyo.

Kotaro Hiramatsu received his PhD in chemistry from the University of Tokyo, Japan, in 2016. He is an assistant professor in the Chemistry Department and the Research Center for Spectral Chemistry at the University of Tokyo and an adjunct researcher of the Precursory Research for Embryonic Science and Technology Program of Japan Science and Technology Agency.

Matthew Lindley received his PhD in chemistry from the University of Tokyo, Japan, in 2021. He is a postdoctoral fellow of the Japan Society for the Promotion of Science hosted in the Department of Engineering at Osaka University.

Julia Gala de Pablo received her PhD in physics from the University of Leeds, United Kingdom, in 2019. She is a postdoctoral fellow in genomics and neuroscience at the School of Biomedical Sciences of the University of Leeds.

Shunsuke Ono received his PhD in communications and integrated system from Tokyo Institute of Technology, Japan, in 2014. He is an associate professor in the Department of Computer Science at Tokyo Institute of Technology.

Keisuke Goda is a professor in the Department of Chemistry at the University of Tokyo, an adjunct professor in the Department of Bioengineering at University of California, Los Angeles (UCLA), and an adjunct professor in the Institute of Technological Sciences at Wuhan University. His research group aims to develop serendipity-enabling technologies based on laser-based molecular imaging and spectroscopy together with microfluidics and computational analytics.

CC BY: © The Authors. Published by SPIE and CLP under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
Shigekazu Takizawa, Kotaro Hiramatsu, Matthew Lindley, Julia Gala de Pablo, Shunsuke Ono, and Keisuke Goda "High-speed hyperspectral imaging enabled by compressed sensing in time domain," Advanced Photonics Nexus 2(2), 026008 (7 March 2023). https://doi.org/10.1117/1.APN.2.2.026008
Received: 17 October 2022; Accepted: 1 February 2023; Published: 7 March 2023
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications.
Advertisement
Advertisement
KEYWORDS
Hyperspectral imaging

Image restoration

Raman spectroscopy

3D acquisition

Compressed sensing

Image acquisition

3D scanning

Back to Top