1.IntroductionFinding and characterizing Earth-like planets orbiting Sun-like stars is one of the most challenging goals of modern radial velocity (RV) exoplanet science.1 Such searches place very demanding requirements on the wavelength calibration of astrophysical spectrographs, specifically, detecting RV shifts over the course of months to years, corresponding to sub-MHz changes in Doppler-broadened stellar absorption lines that are many GHz broad. Atomic emission lines from hollow cathode lamps and absorption lines from iodine vapor cells have been the workhorse calibration tools. However, these sources neither have uniform spectral coverage nor long-term stability. A laser frequency comb (LFC) that is referenced to an atomic clock provides an excellent solution to this problem, as it provides a very large set of equispaced frequency markers with very accurately known absolute frequencies.2–4 Although LFCs for the calibration of astrophysical spectrographs (“astro-combs”) have been successfully demonstrated,2–11 they have not yet seen widespread adoption as primary calibrators in the astronomical community due to their complexity and cost. The operation of astro-combs has so far required significant laser expertise. It is, therefore, imperative to simplify the use of astro-combs11,12 to make them viable for the next generation of high-precision RV measurements. Astro-combs need to have a large mode spacing () to match the resolution of astrophysical spectrographs. Ti:sapphire-based astro-combs facilitate this because these lasers are available with intrinsically larger mode spacing compared with fiber lasers. However, contrary to their fiber laser counterparts, these lasers require occasional realignment. Recently, however, this disadvantage has been overcome with the advent of turn-key Ti:sapphire LFCs. Here, we demonstrate the simplification of the operation of an astro-comb using a turn-key Ti:sapphire LFC, an off-the-shelf supercontinuum device, and existing Fabry–Perot (FP) mode filters. The laser is alignment free and, therefore, greatly simplifies the use of the astro-comb. We study the stability of our system, use it as a reference for measurements of solar spectra, and employ it to perform characterization of an astrophysical spectrograph. We also discuss some potential future improvements to the system. 2.Experimental SetupThe astro-comb is located at the Telescopio Nazionale Galileo (TNG), on the island of La Palma in the Canary Islands, where it is used to calibrate the HARPS-N spectrograph.13 Figure 1 shows a schematic of the experimental setup. The astro-comb light source is the taccor comb (Laser Quantum), based on a turn-key 1-GHz Ti:sapphire mode-locked laser with a carrier-envelope offset (CEO) detection unit. The LFC operates at a center wavelength of about 800 nm and outputs pulses at a repetition rate stabilized to a 1.000010870-GHz signal sourced from an RF synthesizer. The LFC CEO frequency is detected by sampling the optical output and sending it through a short length of nonlinear fiber to an detection unit, which directly locks the CEO frequency to 261.5 MHz. Both synthesizers are referenced to a GPS-disciplined 10-MHz Rb clock. Approximately 300 mW of the source light is coupled into a supercontinuum device (NKT Photonics FemtoWHITE 800) to spectrally broaden the 1-GHz repetition rate comb. This 12-cm-long aluminum-body device contains a photonic crystal fiber (PCF) with a core diameter and a 750-nm zero dispersion wavelength. The device also features hole-collapsed, sealed fiber ends that are mounted in quartz ferrules. The output wavelengths relevant to calibrating the HARPS-N spectrograph are in the - to 600-nm range, but there is also a significant amount of light produced at longer wavelengths, up into the near-infrared region. This light is then filtered by two 16-GHz free spectral range FP cavities in series, achieving suppression of undesired comb teeth.5 The broadband cavities, which are based on zero group delay dispersion mirror pairs,14 are optimized for operation between 500 and 650 nm. The cavity lengths are stabilized to a frequency-doubled 1064-nm CW single-frequency laser (JDSU NPRO 126N-1064-500) using a Pound–Drever–Hall scheme15 in transmission. As the cavities have residual dispersion, the frequency of the CW laser was empirically tuned to maximize the bandwidth transmitted by the cavities. This laser, in turn, is offset locked by heterodyning some of the 1064-nm light with a nearby tooth of an existing Ti:sapphire LFC (Menlo Systems Octavius-1G-HP), which is also referenced to the same GPS-disciplined signal sources as the taccor comb. We would like to stress that, in the permanent setup, the reference laser will be offset locked directly to the taccor comb by heterodyning some of the frequency-doubled reference laser light at 532 nm with a nearby tooth of the PCF-broadened light from the taccor comb. Due to the limited time available for this demonstration, however, we locked the reference laser to the existing Octavius comb as in Ref. 5. The spectrally broadened and filtered astro-comb light is coupled into a multimode fiber and sent through a mode scrambler5 to eliminate dynamic modal noise. The light is then sent via multimode fiber to HARPS-N,13 which is a high-resolution () cross-dispersed echelle spectrograph with spectral coverage from 380 to 690 nm. HARPS-N achieves approximately few m/s RV stability prior to calibration by careful design, operation in vacuum, and temperature stabilization on the millikelvin level. Sub-m/s RV precision depends crucially on wavelength calibration, as well as simultaneous monitoring of potential calibration drifts while science exposures are performed. To this end, two input channels to HARPS-N are present: star light is injected into the “science channel” and calibration light into the “reference channel.” In the present work, we study the performance of the astro-comb by injecting its light into one or both channels of the HARPS-N spectrograph. 3.Astro-Comb CharacterizationFigure 2 shows the broad spectrum of the astro-comb, as measured on the HARPS-N spectrograph. The points of the spectrum lie at 521 and 611 nm. On a finer scale, individual comb spectral lines spaced by about 16 GHz are visible. The contrast of astro-comb peaks (peak height divided by background level) on HARPS-N is . We believe this is due to long tails in the HARPS-N instrument profile as the contrast of the Octavius LFC-based astro-comb, observed with HARPS-N, is similar while its contrast on a high-resolution Fourier transform spectrometer is .5 The strong modulation in the envelope of the spectrum is a result of the nonlinear processes in the supercontinuum device used for spectral broadening. Improved spectral uniformity and even extending spectral coverage can be addressed by designing an optimized PCF for this LFC, and such efforts are currently underway. Alternatively, if the minimum number of counts in the present spectrum is satisfactory for calibration purposes, one could improve spectral uniformity by simply employing a lossy spectral flattening scheme with a spatial light modulator.16 Ultimately, the bandwidth of our astro-comb is limited by the residual dispersion of filtering FP cavities.17 Extending cavity mirror spectral coverage is currently under investigation. An alternative approach that has been successfully demonstrated7–9,12 is to filter a narrowband comb with a series of narrowband high-finesse cavities and then perform the spectral broadening with a nonlinear fiber. This approach extends the bandwidth of the comb at the expense of system complexity, including added demands on FP cavity performance. We operated the astro-comb for several days, investigating its performance and stability. To collect information about frequency stability, we injected astro-comb light into both channels of the HARPS-N spectrograph and monitored the deviation of their difference as a function of averaging time as shown in Fig. 3. We consistently achieved RV sensitivity of nearly at one half hour with no signs of spectrograph drift. Moreover, the two-sample deviation is consistent with the shot noise limit up to this point. This wavelength calibration is more than sufficient for RV detection of an Earth-analog exoplanet ( RV modulation). 4.Comb-Referenced Solar SpectraAs an example of an astronomical application, we performed solar spectral observations with HARPS-N referenced to the astro-comb. Using an automated compact solar telescope located at the TNG facility,18 we collect light from the full disk of the Sun and feed an integrating sphere to discard spatial information. This light is then injected into the science channel of the HARPS-N spectrograph, with the astro-comb light simultaneously injected into the reference channel. We took 20-s exposures for several hours, with a break due to clouds. In these short-term measurements, the astro-comb primarily provides a simultaneous reference as the RV is only measured relative to the initial reference exposures for a few hours. We also derive a wavelength solution from the astro-comb spectrum injected in the science channel. Figure 4(a) shows the difference between the observed RVs (calculated using a cross-correlation technique with an empirical template and averaged across the orders of HARPS-N with significant astro-comb light) and the expected RVs from the JPL “Horizons” ephemeris. The power spectrum of these differences [Fig. 4(b)] prominently shows the 5-min (3 mHz) -mode solar acoustic oscillations. However, there is also significant low-frequency noise present that is likely associated with granulation effects in the Sun.19 5.Studies of Intrapixel Sensitivity Variations of the Spectrograph DetectorA source of systematic error in RV measurements with an astrophysical spectrograph is nonuniformity in the detector. One example is intrapixel sensitivity variations20–22 in the charge-coupled device (CCD). To study this effect, we took a sequence of exposures while shifting the astro-comb lines across half a pixel. Specifically, we shift the comb repetition rate since even a small change in gets magnified by the mode number through the relation defining the frequency of the ’th line, . For example, a step of 3.2 kHz in the repetition rate amounts to moving a comb tooth across an entire pixel (). Note that we continue to take to remain consistent with our discussion of the source comb; however, only every 16th line appears on the spectrograph. To track the shifting astro-comb teeth as the repetition rate is changed, we inject comb light into the science channel of the spectrograph and light from a passively stabilized FP cavity illuminated by broadband white light (a laser-driven plasma source) into the reference channel as a fixed reference. Using a standard cross-correlation analysis, we calculate the mean shift in all the lines relative to the FP spectrum, assuming that the drift of the FP cavity is negligible during the entire measurement. Figure 5 shows the results of this analysis, a linear shift due to a change in repetition rate of the astro-comb of 0.298(2) m/s/Hz, implying , which is a good estimate for the mean value of in . The upper panel of Fig. 5 shows the residuals from the fit with error bars representing the statistical uncertainty of . We attribute additional scatter in the residuals to systematic errors induced by changes in astro-comb power versus wavelength as the repetition rate and reference laser are retuned. These variations do not affect the results reported below and in Fig. 6 as the analysis is henceforth done for each astro-comb peak independently. To search for intrapixel sensitivity variations, we fit all 365 astro-comb spectral peaks in a single echelle order at (near the center of the astro-comb band) on the HARPS-N spectrograph to Gaussian profiles. As seen in the inset of Fig. 2, typical peaks have 3 to 4 pixel full width at half maximum. We model the mean intrapixel sensitivity variation of all the pixels in this order as follows: let be the pixel value of the fitted peak position of the ’th peak in the ’th exposure, where runs from 0 to 364, while runs from 0 to 15. gives the fractional part of the peak position. Note that a value of 0 or 1 corresponds to pixel center while a value of 0.5 corresponds to a pixel boundary. We then compute a residual of the shift of the observed peak in exposure relative to the initial exposure compared with the expectation from shifting the repetition rate as where is the expected shift in pixels of the comb peak at due to the change in repetition rate . The additional correction is the local shift (i.e., interpolated to ) of the FP simultaneous reference between the initial exposure and the ’th exposure. This parameter is extracted from a wavelength solution derived from the FP spectrum. Figure 6(a) shows as a function of for all , . Averaging the data shown in Fig. 6(a) into bins of 0.1 pixels leaves a systematic residual at roughly the 5 millipixel level, as shown in Fig. 6(b), which corresponds to in RV units. Averaging over all the observed lines in all the orders with different fractional CCD pixel values should reduce this systematic error below the level. Key challenges for future work are to determine such intrapixel sensitivity variations across the full HARPS-N spectrum and to mitigate its effects on astronomical RV observations.6.ConclusionsIn summary, we demonstrated an astro-comb employing a turn-key mode-locked Ti:sapphire laser, a commercially available supercontinuum device, and existing FP mode filters. This astro-comb readily achieves RV stability of within one half hour averaging time. It is also successfully used as a reference for measurements of solar spectra and in the study of intrapixel sensitivity variations in the CCD detector of the HARPS-N spectrograph. We are currently working to extend the spectral coverage, improve the intensity uniformity, and fully automate the system (e.g., fiber alignment and filter cavity locks). AcknowledgmentsThis research work was supported by the Harvard Origins of Life Initiative, the Smithsonian Astrophysical Observatory, the National Aeronautics and Space Administration Award No. NNX16AD42G, the National Science Foundation Award No. AST-1405606, and the Italian funding program “Progetti Premiali” WOW. A.R. was supported by a postgraduate scholarship from the Natural Sciences and Engineering Research Council of Canada. ReferencesD. A. Fischer et al.,
“State of the field: extreme precision radial velocities,”
Publ. Astron. Soc. Pac., 128
(964), 066001
(2016). http://dx.doi.org/10.1088/1538-3873/128/964/066001 PASPAU 0004-6280 Google Scholar
C.-H. Li et al.,
“A laser frequency comb that enables radial velocity measurements with a precision of ,”
Nature, 452
(7187), 610
–612
(2008). http://dx.doi.org/10.1038/nature06854 Google Scholar
T. Steinmetz et al.,
“Laser frequency combs for astronomical observations,”
Science, 321
(5894), 1335
–1337
(2008). http://dx.doi.org/10.1126/science.1161030 SCIEAS 0036-8075 Google Scholar
D. A. Braje et al.,
“Astronomical spectrograph calibration with broad-spectrum frequency combs,”
Eur. Phys. J. D, 48
(1), 57
–66
(2008). http://dx.doi.org/10.1140/epjd/e2008-00099-9 EPJDF6 1434-6060 Google Scholar
A. G. Glenday et al.,
“Operation of a broadband visible-wavelength astro-comb with a high-resolution astrophysical spectrograph,”
Optica, 2
(3), 250
–254
(2015). http://dx.doi.org/10.1364/OPTICA.2.000250 Google Scholar
T. Wilken et al.,
“High-precision calibration of spectrographs,”
Mon. Not. R. Astron. Soc., 405
(1), L16
–L20
(2010). http://dx.doi.org/10.1111/j.1745-3933.2010.00850.x MNRAA4 0035-8711 Google Scholar
T. Wilken et al.,
“A spectrograph for exoplanet observations calibrated at the centimetre-per-second level,”
Nature, 485
(7400), 611
–614
(2012). http://dx.doi.org/10.1038/nature11092 Google Scholar
F. Quinlan et al.,
“A 12.5 GHz-spaced optical frequency comb spanning for near-infrared astronomical spectrograph calibration,”
Rev. Sci. Instrum., 81
(6), 063105
(2010). http://dx.doi.org/10.1063/1.3436638 RSINAK 0034-6748 Google Scholar
G. G. Ycas et al.,
“Demonstration of on-sky calibration of astronomical spectra using a 25 GHz near-IR laser frequency comb,”
Opt. Express, 20
(6), 6631
–6643
(2012). http://dx.doi.org/10.1364/OE.20.006631 OPEXFF 1094-4087 Google Scholar
X. Yi et al.,
“Demonstration of a near-IR line-referenced electro-optical laser frequency comb for precision radial velocity measurements in astronomy,”
Nature Commun., 7 10436
(2016). http://dx.doi.org/10.1038/ncomms10436 NCAOBW 2041-1723 Google Scholar
R. A. McCracken et al.,
“Wavelength calibration of a high resolution spectrograph with a partially stabilized 15-GHz astrocomb from 550 to 890 nm,”
Opt. Express, 25
(6), 6450
–6460
(2017). http://dx.doi.org/10.1364/OE.25.006450 OPEXFF 1094-4087 Google Scholar
R. A. Probst et al.,
“A laser frequency comb featuring sub-cm/s precision for routine operation on HARPS,”
Proc. SPIE, 9147 91471C
(2014). http://dx.doi.org/10.1117/12.2055784 PSISDG 0277-786X Google Scholar
R. Cosentino et al.,
“HARPS-N: the new planet hunter at TNG,”
Proc. SPIE, 8446 84461V
(2012). http://dx.doi.org/10.1117/12.925738 Google Scholar
L.-J. Chen et al.,
“Broadband dispersion-free optical cavities based on zero group delay dispersion mirror sets,”
Opt. Express, 18
(22), 23204
–23211
(2010). http://dx.doi.org/10.1364/OE.18.023204 OPEXFF 1094-4087 Google Scholar
R. W. P. Drever et al.,
“Laser phase and frequency stabilization using an optical resonator,”
Appl. Phys. B, 31
(2), 97
–105
(1983). http://dx.doi.org/10.1007/BF00702605 Google Scholar
R. A. Probst et al.,
“Spectral flattening of supercontinua with a spatial light modulator,”
88641Z
(2013). http://dx.doi.org/10.1117/12.2036601 Google Scholar
G. Chang et al.,
“Optimization of filtering schemes for broadband astro-combs,”
Opt. Express, 20
(22), 24987
–25013
(2012). http://dx.doi.org/10.1364/OE.20.024987 OPEXFF 1094-4087 Google Scholar
X. Dumusque et al.,
“HARPS-N observes the Sun as a star,”
Astophys. J. Lett., 814 L21
(2015). http://dx.doi.org/10.1088/2041-8205/814/2/L21 Google Scholar
X. Dumusque et al.,
“Planetary detection limits taking into account stellar noise. I. Observational strategies to reduce stellar oscillation and granulation effects,”
Astron. Astrophys., 525 A140
(2011). http://dx.doi.org/10.1051/0004-6361/201014097 AAEJAF 0004-6361 Google Scholar
A. Piterman and Z. Ninkov,
“Subpixel sensitivity maps for a back-illuminated charge-coupled device and the effects of nonuniform response on measurement accuracy,”
Opt. Eng., 41
(6), 1192
–1202
(2002). http://dx.doi.org/10.1117/1.1476691 Google Scholar
H. Toyozumi and M. C. B. Ashley,
“Intra-pixel sensitivity variation and charge transfer inefficiency—results of CCD scans,”
Publ. Astron. Soc. Aust., 22
(3), 257
–266
(2005). http://dx.doi.org/10.1071/AS05013 PASAFO 1323-3580 Google Scholar
M. T. Murphy et al.,
“Laser frequency comb techniques for precise astronomical spectroscopy,”
Mon. Not. R. Astron. Soc., 422
(1), 761
–771
(2012). http://dx.doi.org/10.1111/j.1365-2966.2012.20656.x MNRAA4 0035-8711 Google Scholar
|