Paper
25 February 2016 Oxygen detection system consisting of a millimeter wave Fabry-Pérot resonator and an integrated SiGe front-end
Julia Wecker, Andreas Bauch, Steffen Kurth, Gauri Mangalgiri, Markus Gaitzsch, Marco Meinig, Thomas Gessner, Ismail Nasr, Robert Weigel, Dietmar Kissinger, Angelika Hackner, Ulrich Prechtel
Author Affiliations +
Abstract
Oxygen shows significant absorption lines in the millimeter wave spectrum. Resonators are widely used to achieve a strong absorption even with a short absorption paths length for concentration measurements. A sensor system based on a Fabry-Pérot resonator for oxygen measurements at ambient pressure is presented here. The Fabry-Pérot resonator consists of two metal mirrors with a diameter of 50 mm. For purpose of oxygen detection the resonator covers a frequency range between 55 GHz and 65 GHz with a resonant peak density between 1 GHz and 1.5 GHz, depending on the mirror distance, and a quality factor of approximately 7000. To achieve a compact sensor system the concept envisages two integrated transceiver circuits directly coupling to coaxial ports in the metal mirrors of the resonator. The integrated SiGe front-end addresses a frequency band from 50 GHz to 75 GHz. They are realized as heterodyne structures with integrated directional couplers, thus it is possible to measure scattering parameters. For first oxygen concentration measurements, the resonator sample was coupled to a commercially available Vector Network Analyzer. The cavity was filled with oxygen concentrations of 0% vol. and 20% vol. at ambient pressure and temperature resulting in a significant change of the quality factor for frequencies close to the oxygen absorption line at 60.6 GHz. The sensor does not contain hot components. This is an advantage compared to other oxygen sensors, like electrochemical or metal-oxide sensors.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Julia Wecker, Andreas Bauch, Steffen Kurth, Gauri Mangalgiri, Markus Gaitzsch, Marco Meinig, Thomas Gessner, Ismail Nasr, Robert Weigel, Dietmar Kissinger, Angelika Hackner, and Ulrich Prechtel "Oxygen detection system consisting of a millimeter wave Fabry-Pérot resonator and an integrated SiGe front-end", Proc. SPIE 9747, Terahertz, RF, Millimeter, and Submillimeter-Wave Technology and Applications IX, 97470C (25 February 2016); https://doi.org/10.1117/12.2210915
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Resonators

Oxygen

Sensors

Absorption

Mirrors

Extremely high frequency

Reflectors

Back to Top