Paper
27 February 2015 Volume refractometry of liquids using stable optofluidic Fabry-Pérot resonator with curved surfaces
Noha Gaber, Yuto Takemura, Maurine Malak, Frédéric Marty, Diaa Khalil, Dan Angelescu, Elodie Richalot, Tarik Bourouina
Author Affiliations +
Proceedings Volume 9375, MOEMS and Miniaturized Systems XIV; 93750T (2015) https://doi.org/10.1117/12.2076034
Event: SPIE OPTO, 2015, San Francisco, California, United States
Abstract
This work reports a simple, miniaturized optical sensing module for liquid refractometry. It is based on a stable Fabry- Perot resonator consisting of two silicon cylindrical mirrors with a cylindrical lens in the core. The lens is formed by a capillary tube through which the analyte to be analyzed passes. This setup enables volume refractometry, where light propagates through the sample realizing high interaction depth. The cylindrical surfaces achieve light confinement, reducing the light escaping loss encountered in classical cavities with straight mirrors; and hence high quality factor (Q) over 1,000 is attained. Exploiting this high Q, we adopt uncommon refraction index (RI) measurement criterion: we operate at a fixed wavelength and detect the power drop caused as a consequence to the spectral shift with RI change. Performing experimental testing using a tunable laser and a power-meter, the normalized spectra for different mixture ratios of acetone and deionized water are obtained. The wavelength corresponding to the maximal power transmission from pure acetone is taken as a reference. A vertical line at this wavelength cuts the successive transmission curves and enables measuring the power drop in the linear region, and from it the refractive index change Δn above the refractive index of the reference solution can be determined for 0.0023<Δn<0.0045. Sensitivity up to 4,094 dBm/RIU is achieved. A wider range is still accessible by the conventional method of tracing the shift in peak wavelengths: a range of Δn=0.0163 RIU can be scanned, with a sensitivity of 221 nm/RIU. Error analysis has been accomplished, and the design parameters of the device are discussed to evaluate the performance.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Noha Gaber, Yuto Takemura, Maurine Malak, Frédéric Marty, Diaa Khalil, Dan Angelescu, Elodie Richalot, and Tarik Bourouina "Volume refractometry of liquids using stable optofluidic Fabry-Pérot resonator with curved surfaces", Proc. SPIE 9375, MOEMS and Miniaturized Systems XIV, 93750T (27 February 2015); https://doi.org/10.1117/12.2076034
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Refractive index

Sensors

Refractometry

Mirrors

Liquids

Resonators

Water

Back to Top