Paper
27 June 1988 ROC Detectability Evaluation Of A Filmless Digital Radiographic System
Gary S. Shaber, Richard Shlansky-Goldberg, Arthur J. D'Adamo
Author Affiliations +
Abstract
A new digital radiographic system (Matrix Laser Rad) employing a filmless photostimulable reusable phosphor (PSP) was evaluated for spatial resolution and high and low contrast object detectability. Receiver operator characteristic curve (ROC) comparisons were made to film images using equal or lower exposure factors. The low and high contrast test objects for the ROC evaluation were respectively a 5/32 inch diameter hemispheric depression filled with mineral oil and 250-500 micrometer diameter silicon carbide granules, both in a 2 inch thick plexiglass block. These object sizes were shown to be at thresh-old of detectability for either the film or PSP system at the exposure factors used. The ROC curves were generated from data obtained by radiologists viewing multiple film radiographs and CRT displays of both the digitized film radiographs and PSP images with the test objects in random locations. There were 90 images generated for each system, 45 with test objects and 45 without. Each observer had 15 seconds at a fixed distance to view each image presented at random at standard view box intensities (140 foot-lamberts) on either a light view box or CRT. The unenhanced filmless PSP radiographs had a reduced detectability threshold for the test objects, however with the use of windowing, level manipulations and appropriate filtering, detectability could be improved for the low contrast objects with the digital system surpassing unenhanced film radiographs. In addition, a dose reduction could be achieved with the PSP filmless system without loss of significant detectability. Enhanced film radiographs demonstrated the highest detectability characteristics. To achieve similar detectability for high contrast objects with the PSP system, a significant increase in object size was necessary.
© (1988) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Gary S. Shaber, Richard Shlansky-Goldberg, and Arthur J. D'Adamo "ROC Detectability Evaluation Of A Filmless Digital Radiographic System", Proc. SPIE 0914, Medical Imaging II, (27 June 1988); https://doi.org/10.1117/12.968681
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Spatial resolution

Radiography

Molybdenum

Receivers

CRTs

Magnetic resonance imaging

Silicon carbide

RELATED CONTENT

Statistical properties of spin noise in MRI
Proceedings of SPIE (March 18 2008)
Diffraction imaging with conventional sources
Proceedings of SPIE (September 22 2008)
Analysis of the spectrum in phase-contrast mammography
Proceedings of SPIE (March 13 2009)
Recent advances in columnar CsI(Tl) scintillator screens
Proceedings of SPIE (September 16 2005)
Display for medical imaging
Proceedings of SPIE (December 18 2000)

Back to Top