Paper
8 May 2014 Real-time data processing for in-line monitoring of a pharmaceutical coating process by optical coherence tomography
Daniel Markl, Jakob Ziegler, Günther Hannesschläger, Stephan Sacher, Andreas Buchsbaum, Michael Leitner, Johannes G. Khinast
Author Affiliations +
Abstract
Coating of tablets is a widely applied unit operation in the pharmaceutical industry. Thickness and uniformity of the coating layer are crucial for efficacy as well as for compliance. Not only due to different initiatives it is thus essential to monitor and control the coating process in-line. Optical coherence tomography (OCT) was already shown in previous works to be a suitable candidate for in-line monitoring of coating processes. However, to utilize the full potential of the OCT technology an automatic evaluation of the OCT measurements is essential. The automatic evaluation is currently implemented in MATLAB and includes several steps: (1) extraction of features of each A-scan, (2) classification of Ascan measurements based on their features, (3) detection of interfaces (air/coating and coating/tablet core), (4) correction of distortions due to the curvature of the bi-convex tablets and the oblique orientation of the tablets, and (5) determining the coating thickness. The algorithm is tested on OCT data acquired by moving the sensor head of the OCT system across a static tablet bed. The coating thickness variations of single tablets (i.e., intra-tablet coating variability) can additionally be analyzed as OCT allows the measurement of the coating thickness on multiple displaced positions on one single tablet. Specifically, the information about those parameters emphasizes the high capability of the OCT technology to improve process understanding and to assure a high product quality.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Daniel Markl, Jakob Ziegler, Günther Hannesschläger, Stephan Sacher, Andreas Buchsbaum, Michael Leitner, and Johannes G. Khinast "Real-time data processing for in-line monitoring of a pharmaceutical coating process by optical coherence tomography", Proc. SPIE 9129, Biophotonics: Photonic Solutions for Better Health Care IV, 91290M (8 May 2014); https://doi.org/10.1117/12.2051138
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tablets

Coating

Optical coherence tomography

Head

Interfaces

Sensors

Image processing

RELATED CONTENT

MIFD Net a hand gesture recognition model based...
Proceedings of SPIE (January 12 2023)
SXGA resolution IR sensor-STAIRS C
Proceedings of SPIE (July 29 2002)
Onboard spectral imager data processor
Proceedings of SPIE (October 27 1999)

Back to Top