16 May 2013 Automatic alignment of double optical paths in excimer laser amplifier
Dahui Wang, Xueqing Zhao, Hengqi Hua, Yongsheng Zhang, Yun Hu, Aiping Yi, Jun Zhao
Author Affiliations +
Proceedings Volume 8796, 2nd International Symposium on Laser Interaction with Matter (LIMIS 2012); 879625 (2013) https://doi.org/10.1117/12.2011273
Event: 2nd International Symposium on Laser Interaction with Matter (LIMIS 2012), 2012, Xi'an, Shaanxi, China
Abstract
A kind of beam automatic alignment method used for double paths amplification in the electron pumped excimer laser system is demonstrated. In this way, the beams from the amplifiers can be transferred along the designated direction and accordingly irradiate on the target with high stabilization and accuracy. However, owing to nonexistence of natural alignment references in excimer laser amplifiers, two cross-hairs structure is used to align the beams. Here, one crosshair put into the input beam is regarded as the near-field reference while the other put into output beam is regarded as the far-field reference. The two cross-hairs are transmitted onto Charge Coupled Devices (CCD) by image-relaying structures separately. The errors between intersection points of two cross-talk images and centroid coordinates of actual beam are recorded automatically and sent to closed loop feedback control mechanism. Negative feedback keeps running until preset accuracy is reached. On the basis of above-mentioned design, the alignment optical path is built and the software is compiled, whereafter the experiment of double paths automatic alignment in electron pumped excimer laser amplifier is carried through. Meanwhile, the related influencing factors and the alignment precision are analyzed. Experimental results indicate that the alignment system can achieve the aiming direction of automatic aligning beams in short time. The analysis shows that the accuracy of alignment system is 0.63μrad and the beam maximum restoration error is 13.75μm. Furthermore, the bigger distance between the two cross-hairs, the higher precision of the system is. Therefore, the automatic alignment system has been used in angular multiplexing excimer Main Oscillation Power Amplification (MOPA) system and can satisfy the requirement of beam alignment precision on the whole.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dahui Wang, Xueqing Zhao, Hengqi Hua, Yongsheng Zhang, Yun Hu, Aiping Yi, and Jun Zhao "Automatic alignment of double optical paths in excimer laser amplifier", Proc. SPIE 8796, 2nd International Symposium on Laser Interaction with Matter (LIMIS 2012), 879625 (16 May 2013); https://doi.org/10.1117/12.2011273
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Automatic alignment

Excimer lasers

Mirrors

Optical amplifiers

Near field optics

Charge-coupled devices

Optical alignment

RELATED CONTENT

Automatic alignment technology in high power laser system
Proceedings of SPIE (February 03 2015)
Optical alignment of the LBT prime focus camera
Proceedings of SPIE (September 30 2004)
Laser chain alignment with low-power local light sources
Proceedings of SPIE (December 08 1995)

Back to Top