Paper
15 October 2012 Measurement of cathode luminescence efficiency of phosphors for micro-channel plate based x-ray framing cameras
N. Izumi, J. Emig, J. Moody, C. Middeleton, J. Holder, S. Glenn, T. Pond, R. Shellman, M. Cardenas, P. J. Walsh, S. J. Chelli, D. K. Bradley, P. M. Bell
Author Affiliations +
Abstract
From a point of a signal-to-background ratio, phosphors are a key component of micro channel plate (MCP) based x-ray framing cameras. In an MCP based framing camera, x-ray signal is converted to electrons, gated, amplified, and converted back to optical signal on the phosphor. To operate x-ray framing cameras in a harsh neutron induced radiation background of the National Ignition Facility, cathodeluminescence efficiency of the phosphor is very important. To avoid MCP damage due to high voltage breakdown, we have been operating phosphors below 3kV (acceleration field < 6 kV/mm). The signal-to-background ratio the camera can be significantly improved by increasing the phosphor potential to 10kV. We measured conversion efficiencies of standard phosphors at electron energies of 0.5 ~10 keV and assessed achievable performance of them with using a numerical model.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
N. Izumi, J. Emig, J. Moody, C. Middeleton, J. Holder, S. Glenn, T. Pond, R. Shellman, M. Cardenas, P. J. Walsh, S. J. Chelli, D. K. Bradley, and P. M. Bell "Measurement of cathode luminescence efficiency of phosphors for micro-channel plate based x-ray framing cameras", Proc. SPIE 8505, Target Diagnostics Physics and Engineering for Inertial Confinement Fusion, 85050I (15 October 2012); https://doi.org/10.1117/12.930992
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cameras

Electrons

Microchannel plates

X-rays

Aluminum

Data conversion

Photometry

RELATED CONTENT

Operating a large-area MPP-CCD with antiblooming
Proceedings of SPIE (April 10 1995)
Efficiency and decay time measurement of phosphors for x ray...
Proceedings of SPIE (September 27 2011)
X ray imaging in an environment with high neutron background...
Proceedings of SPIE (September 13 2011)
Effect of low energy protons on the performance of the...
Proceedings of SPIE (December 13 2000)
A Soft X Ray Streak Camera Using A Microchannel Plate...
Proceedings of SPIE (February 04 1988)
Energy-resolved soft x-ray framing camera
Proceedings of SPIE (August 01 2003)

Back to Top