Paper
13 May 2011 A reduced-order disturbance observer applied to inertially stabilized line-of-sight control
J. M. Hilkert, Brian Pautler
Author Affiliations +
Abstract
One of the key factors that determine how well an inertially stabilized Line-of-Sight control system performs is the ability of the feedback loop to counteract, or reject disturbances such as friction and mass imbalance. These disturbances are usually a function of both the electro-mechanical design and the dynamic operating environment. In a typical control system, this disturbance rejection capability is determined primarily by the loop bandwidth which, in turn, is directly affected by the dynamic characteristics of the gyro, actuator or motor, structural interactions within the system, and noise coupling from the gyro or other sources. A state estimator, configured as a disturbance observer, has been previously shown to be an effective method to augment the control system and improve the disturbance rejection performance. This paper discusses a particularly straightforward reduced-order generic observer design which is relatively insensitive to system parameters and is simple enough that it can be implemented with a few lines of digital code or an analog circuit. The effectiveness of the design is investigated with respect to both its performance and its robustness.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
J. M. Hilkert and Brian Pautler "A reduced-order disturbance observer applied to inertially stabilized line-of-sight control", Proc. SPIE 8052, Acquisition, Tracking, Pointing, and Laser Systems Technologies XXV, 80520H (13 May 2011); https://doi.org/10.1117/12.884123
Lens.org Logo
CITATIONS
Cited by 21 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Gyroscopes

Control systems

Error analysis

Line of sight stabilization

Linear filtering

Systems modeling

Amplifiers