Paper
13 October 2010 Multiple vicarious calibration using combined accuracy estimation
Stefan Livens, Sindy Sterckx, Wouter Dierckx, Stefan Adriaensen, Ils Reusen
Author Affiliations +
Abstract
Radiometric calibration often employs several independent vicarious calibration techniques to increase robustness and accuracy. We present a statistical methodology for combining results in a hierarchical scheme. The method, developed for the PROBA-V remote sensing mission, is based on handling and propagating of accuracies in accordance with the ISO GUM. Robust estimation is performed and outliers removed. Results over different sites are combined using weighted averaging. Weighted linear regression is used for temporal averaging. Results from different methods are combined taking into account possible bias. Finally an operational update strategy is proposed which relies on a significance criterion.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Stefan Livens, Sindy Sterckx, Wouter Dierckx, Stefan Adriaensen, and Ils Reusen "Multiple vicarious calibration using combined accuracy estimation", Proc. SPIE 7826, Sensors, Systems, and Next-Generation Satellites XIV, 782623 (13 October 2010); https://doi.org/10.1117/12.865128
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Data modeling

Error analysis

Remote sensing

Satellites

Sensors

Statistical analysis

Back to Top