22 February 2010 Analysis of the short-pulsed CO2 laser ablation process for optimizing the processing performance for cutting bony tissue
Markus Mehrwald, Jessica Burgner, Christoph Platzek, Claus Feldmann, Jörg Raczkowsky, Heinz Wörn
Author Affiliations +
Abstract
Recently we established an experimental setup for robot-assisted laser bone ablation using short-pulsed CO2 laser. Due to the comparable low processing speed of laser bone ablation the application in surgical interventions is not yet feasible. In order to optimize this ablation process, we conducted a series of experiments to derive parameters for a discrete process model. After applying single and multiple laser pulses with varying intensity onto bone, the resulting craters were measured using a confocal microscope in 3D. The resulting ablation volumes were evaluated by applying Gaussian function fitting. We then derived a logarithmic function for the depth prediction of laser ablation on bone. In order to increase the ablation performance we conducted experiments using alternate fluids replacing the water spray: pure glycerin, glycerin/water mixture, acids and bases. Because of the higher boiling point of glycerin compared to water we had expected deeper craters through the resulting higher temperatures. Experimental results showed that glycerin or a glycerin/water mix do not have any effect on the depth of the ablation craters. Additionally applying the acid or base on to the ablation site does only show minor benefits compared to water. Furthermore we preheated the chemicals with a low energy pulse prior to the ablation pulse, which also showed no effect. However, applying a longer soaking time of the chemicals induced nearly a doubling of the ablation depth in some cases. Furthermore with this longer soaking time, carbonization at the crater margins does not occur as is observed when using conventionally water spray.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Markus Mehrwald, Jessica Burgner, Christoph Platzek, Claus Feldmann, Jörg Raczkowsky, and Heinz Wörn "Analysis of the short-pulsed CO2 laser ablation process for optimizing the processing performance for cutting bony tissue", Proc. SPIE 7562, Optical Interactions with Tissues and Cells XXI, 75620P (22 February 2010); https://doi.org/10.1117/12.841981
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Laser ablation

Bone

Laser cutting

Carbon dioxide lasers

Microscopes

Laser tissue interaction

Laser processing

Back to Top