Paper
11 September 2009 Neutron energy measurements in emergency response applications
Sanjoy Mukhopadhyay, Paul Guss, Michael Hornish, Scott Wilde, Tom Stampahar, Michael Reed
Author Affiliations +
Abstract
We present significant results in recent advances in the measurement of neutron energy. Neutron energy measurements are a small but significant part of radiological emergency response applications. Mission critical information can be obtained by analyzing the neutron energy given off from radioactive materials. In the case of searching for special nuclear materials, neutron energy information from an unknown source can be of importance. At the Remote Sensing Laboratory (RSL) of National Security Technologies, LLC, a series of materials, viz., liquid organic scintillator (LOS), Lithium Gadolinium Borate (LGB) or Li6Gd(BO3)3 in a plastic matrix, a recently developed crystal of Cesium Lithium Yttrium Chloride, Cs2LiYCl6: Ce (called CLYC)[1], and normal plastic scintillator (BC-408) with 3He tubes have been used to study their effectiveness as a portable neutron energy spectrometer. Comparisons illustrating the strengths of the various materials will be provided. Of these materials, LGB offers the ability to tailor its response to the neutron spectrum by varying the isotopic composition of the key constituents (Lithium, Gadolinium [Yttrium], and Boron). All three of the constituent elements possess large neutron capture cross section isotopes for highly exothermic reactions. These compounds of composition Li6Gd(Y)(BO3)3 can be activated by Cerium ions Ce3+. CLYC, on the other hand, has a remarkable gamma response in addition to superb neutron discrimination, comparable to that of Europium-doped Lithium Iodide (6LiI: Eu). Comparing these two materials, CLYC has higher light output (4500 phe/MeV) than that from 6LiI: Eu and shows better energy resolution for both gamma and neutron pulse heights. Using CLYC, gamma energy pulses can be discriminated from the neutron signals by simple pulse height separation. For the cases of both LGB and LOS, careful pulse shape discrimination is needed to separate the gamma energy signals from neutron pulses. Both analog and digital methods have been applied to obtain a clear gamma and neutron energy spectrum in a mixed radiation field. A waveform digitizer manufactured by Agilent Technology Inc. has been successfully used to digitize the signal and separate the gamma and neutron signals to obtain a high gamma rejection ratio. These results along with some interesting data from a plastic (BC-408) and 3He dual gamma-neuron detector will be presented.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Sanjoy Mukhopadhyay, Paul Guss, Michael Hornish, Scott Wilde, Tom Stampahar, and Michael Reed "Neutron energy measurements in emergency response applications", Proc. SPIE 7449, Hard X-Ray, Gamma-Ray, and Neutron Detector Physics XI, 744913 (11 September 2009); https://doi.org/10.1117/12.824624
Lens.org Logo
CITATIONS
Cited by 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scintillators

Lithium

Sensors

Fusion energy

Gadolinium

Crystals

Gamma radiation

Back to Top