Paper
1 August 2007 Z-Scan measurement of thermal optical nonlinearities
I. Dancus, A. Petris, Petronela Doia, E. Fazio, V. I. Vlad
Author Affiliations +
Proceedings Volume 6785, ROMOPTO 2006: Eighth Conference on Optics; 67851F (2007) https://doi.org/10.1117/12.757946
Event: ROMOPTO 2006: Eighth Conference on Optics, 2006, Sibiu, Romania
Abstract
The thermal third order nonlinearity of a neutral density glass is measured using the Z-Scan method. The measurements are performed using two different laser configurations: a continuous wave laser at 532 nm and a femtosecond laser at 1060 nm. The measurements are used to determine the nonlinear refractive index, n2 and the thermo-optical coefficien dn/dt of the samples. The measurements in the two different laser configurations are in good agreement with the existing theory models.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
I. Dancus, A. Petris, Petronela Doia, E. Fazio, and V. I. Vlad "Z-Scan measurement of thermal optical nonlinearities", Proc. SPIE 6785, ROMOPTO 2006: Eighth Conference on Optics, 67851F (1 August 2007); https://doi.org/10.1117/12.757946
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Femtosecond phenomena

Refractive index

Nonlinear optics

Sensors

Absorption

Thermal effects

Continuous wave operation

Back to Top