12 March 2007 A robust meshing and calibration approach for sensorless freehand 3D ultrasound
Author Affiliations +
Abstract
The elevational distance between two ultrasound images can be obtained from the correlation between the two images, leading to sensorless freehand 3D ultrasound systems. Most of these systems rely on the correlation between patches of fully developed speckles (FDS). Previous work has compared different FDS detectors and concluded that the elevational distance measurement limited to the FDS patches obtained by low order moment test yields significantly more accurate results than other FDS detectors. However, small coherent and FDS regions are spread throughout a typical ultrasound image of real tissue. This makes it extremely unlikely to find a regularly shaped (conventionally a rectangle) FDS patch, making it infeasible to estimate elevational distance accurately1. In this work, first we propose a simple and fast algorithm which is capable of detecting arbitrarily irregular FDS regions in an ultrasound image. In vitro experiments on beef liver, beef steak and chicken breast indicates that the proposed algorithm generates remarkably more FDS patches than the current methods. Preliminary results show that the FDS patches obtained by this algorithm generate more accurate elevational distance measurement. Second, we propose a new calibration scheme to generate decorrelation curves. At a particular location in the image, conventional methods acquire one decorrelation curve. We create multiple curves, as a function of particular statistical properties of the patch. The results reveal a theoretically expected relation between the decorrelation curve and the statistical properties of the patch. As a result of this calibration based on the patch statistical properties, improvement in the out of plane motion estimation is expected.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hassan Rivaz, Emad Boctor, and Gabor Fichtinger "A robust meshing and calibration approach for sensorless freehand 3D ultrasound", Proc. SPIE 6513, Medical Imaging 2007: Ultrasonic Imaging and Signal Processing, 651318 (12 March 2007); https://doi.org/10.1117/12.712423
Lens.org Logo
CITATIONS
Cited by 11 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ultrasonography

Calibration

Motion estimation

Sensors

Distance measurement

Liver

Tissues

Back to Top