Paper
29 March 2007 In vivo quantification of human lung dose response relationship
Walter O'Dell, Peng Wang, Haisong Liu, David Fuller, Michael C. Schell, Paul Okunieff M.D.
Author Affiliations +
Abstract
Purpose: To implement a new non-invasive in-vivo assay to compute the dose-response relationship following radiation-induced injury to normal lung tissue, using computed tomography (CT) scans of the chest. Methods and Materials: Follow-up volumetric CT scans were acquired in patients with metastatic tumors to the lung treated using stereotactic radiation therapy. The images reveal a focal region of fibrosis corresponding to the high-dose region and no observable long-term damage in distant sites. For each pixel in the follow-up image the treatment dose and the change in apparent tissue density was compiled. For each of 12 pre-selected dose levels the average pixel tissue density change was computed and fit to a two-parameter dose-response model. The sensitivity of the resulting fits to registration error was also quantified. Results: Complete in vivo dose-response relationships in human normal lung tissue were computed. Increasing radiation sensitivity was found with larger treatment volume. Radiation sensitivity increased also over time up to 12 months, but decreased at later time points. The time-course of dose response correlated with the time-course of levels of circulating IL-1&agr;, TGF&bgr; and MCP-1. The method was found to be robust to registration errors up to 3 mm. Conclusions: This approach for the first time enables the quantification of the full range dose response relationship in human subjects. The method may be used to assess quantitatively the efficacy of various agents thought to illicit radiation protection to the lung.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Walter O'Dell, Peng Wang, Haisong Liu, David Fuller, Michael C. Schell, and Paul Okunieff M.D. "In vivo quantification of human lung dose response relationship", Proc. SPIE 6511, Medical Imaging 2007: Physiology, Function, and Structure from Medical Images, 65110X (29 March 2007); https://doi.org/10.1117/12.710585
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Lung

Tissues

Computed tomography

In vivo imaging

Radiotherapy

X-ray computed tomography

Image registration

Back to Top