Paper
2 March 2006 Effects of collimator dependency and correction methods on I-123 SPECT images using x-ray-based attenuation map
Yu-Wen Yang, Jyh-Cheng Chen, Chia-Jung Chang, Cheng-Yi Cheng, Wen-Sheng Huang
Author Affiliations +
Abstract
Low energy (LE) collimator is generally used in I-123 SPECT imaging. However, the septal penetration and scattering of photons emitted with energy above 159 keV will affect the image contrast and quantitative accuracy of images. To reduce this effect, medium energy (ME) collimator has been used with the cost of lower counting statistics and spatial resolution. The effects of collimator dependency on the quantitative accuracy of attenuation corrected (AC) I-123 SPECT images using X-ray-based attenuation map was investigated. Both brain and heart/thorax phantoms were used to evaluate different degree of attenuation effect between brain and thorax. Experiments were performed at different target-to-background ratios to simulate different object contrast. Both photopeak and scatter projections were collected for dual-energy window scatter correction (SC). Images were reconstructed and compared using different reconstruction methods, which included FBP (filtered backprojection), and OSEM (ordered subset expectation maximization) without corrections, with AC, with SC, and with AC and SC. In both phantom studies, the image contrast and quantitative accuracy were both improved with the use of CT-based transmission map for AC. The image contrast provided by ME collimator was better than that of LE collimator, especially in the region with void activity of thorax phantom. From the results of phantom studies, medium energy collimator with CT-based transmission map showed improvements in image contrast and quantitative accuracy of I-123 SPECT images.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yu-Wen Yang, Jyh-Cheng Chen, Chia-Jung Chang, Cheng-Yi Cheng, and Wen-Sheng Huang "Effects of collimator dependency and correction methods on I-123 SPECT images using x-ray-based attenuation map", Proc. SPIE 6142, Medical Imaging 2006: Physics of Medical Imaging, 61423Z (2 March 2006); https://doi.org/10.1117/12.653007
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Collimators

Signal attenuation

Single photon emission computed tomography

Heart

Photons

Brain

Lung

Back to Top