Paper
7 February 2006 Sensitive ultrashort pulse chirp measurement
Author Affiliations +
Abstract
The chirp of an ultrashort laser pulse can be extracted accurately in real-time using a simple modified autointerferometric correlation (MOSAIC) technique. Our newly developed time-domain algorithm is well suited for low signal-to-noise conditions. We display results revealing high sensitivity to chirp with signal-to-noise levels approaching the noise floor. Correction algorithms have been developed to accommodate signal distortions arising from bandwidth limitations, interferometer misalignment, and non-quadratic detector response.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Daniel A. Bender, Michael P. Hasselbeck, and Mansoor Sheik-Bahae "Sensitive ultrashort pulse chirp measurement", Proc. SPIE 5991, Laser-Induced Damage in Optical Materials: 2005, 59912G (7 February 2006); https://doi.org/10.1117/12.638797
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Algorithm development

Signal to noise ratio

Ultrafast phenomena

Detection and tracking algorithms

Interferometers

Sensors

Interference (communication)

RELATED CONTENT