Paper
20 December 1985 Performance of an Open Path FTIR Air Monitor
Pamela S. H. Fitch, Sidney W. Fleming, Bruce C. McIntosh
Author Affiliations +
Proceedings Volume 0553, Fourier and Computerized Infrared Spectroscopy; (1985) https://doi.org/10.1117/12.970905
Event: 1985 International Conference on Fourier and Computerized Infrared Spectroscopy, 1985, Ottawa, Canada
Abstract
A new type of hazardous gas monitoring system has been installed and tested in a chemical manufacturing facility. It detects the possible presence of several hazardous gases in an open air path by FTIR Spectroscopy. A ruggedized commercial FTIR instrument is coupled through a 10" beam expanding telescope through a path approximately 100 meters long. The FTIR detector is mounted at the focus of a second identical telescope. This paper des cribes the system and the results of the testing.
© (1985) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Pamela S. H. Fitch, Sidney W. Fleming, and Bruce C. McIntosh "Performance of an Open Path FTIR Air Monitor", Proc. SPIE 0553, Fourier and Computerized Infrared Spectroscopy, (20 December 1985); https://doi.org/10.1117/12.970905
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
FT-IR spectroscopy

Telescopes

Sensors

Spectroscopy

Gases