5 June 2003 Practical strategies for the clinical implementation of matrix inversion tomosynthesis (MITS)
Author Affiliations +
Abstract
Digital tomosynthesis is a method that enables the retroactive reconstruction of arbitrary tomographic planes in an object from a finite series of digital projection radiographs, acquired with limited angle tube movement. Conventional tomosynthesis suffers from the presence of blurring artifacts, created by objects located outside of each reconstructed plane. Matrix inversion tomosynthesis (MITS) utilizes known acquisition geometry to solve directly for the unwanted out-of-plane blur artifacts, thus enabling their removal. This paper examines practical strategies for the implementation of MITS in a clinical setting, on a flat-panel fast-readout detector, with the aim of minimizing procedure time and image reconstruction artifacts concurrently. Topics include a comparison of continuous vs. incremental tube motion, the presence of reconstruction artifacts due to error in computing the x-ray tube location, the effect of scrubbing the detector between projections to reduce image retention, and a method for accounting for data that gets projected off the detector. We conclude that MITS is robust enough to be clinically applicable, even under less-than-ideal conditions. Rapid image acquisition with continuous tube movement and no detector scrubbing is clinically desirable for MITS imaging of the chest, where patient motion is a concern. Knowledge of the source-detector geometry can be satisfactorily determined via either a lead fiducial marker placed on the patient, or a tube motion device with sufficient precision and accuracy. Extrapolation of data at the top and bottom of projection images provides excellent amelioration of image truncation artifacts.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Devon J. Godfrey, Amber Rader, and James T. Dobbins III "Practical strategies for the clinical implementation of matrix inversion tomosynthesis (MITS)", Proc. SPIE 5030, Medical Imaging 2003: Physics of Medical Imaging, (5 June 2003); https://doi.org/10.1117/12.480352
Lens.org Logo
CITATIONS
Cited by 36 scholarly publications and 8 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Tomography

X-rays

Chest

Reconstruction algorithms

Radiography

X-ray imaging

Back to Top