Paper
18 December 2000 Photomultiplier tube detector performance and stability for the Earth Observing System's SOLSTICE II instrument
Virginia Ann Drake, William E. McClintock, Richard A. Kohnert, Thomas N. Woods, Gary J. Rottman
Author Affiliations +
Abstract
The goal of the Earth Observing System (EOS) SOLar STellar Irradiance Comparison Experiment II (SOLSTICE II) is to measure the solar ultraviolet irradiance (115 nm - 320 nm) to within 5% of its absolute value with a 0.5% per year relative accuracy over the course of a minimum mission lifetime of five years. Most detectors degrade over time while studying the sun. The SOLSTICE instrument design is such that detector and optical system degradation is tracked by routinely observing a series of stable early-type stars. Any changes in the system may then be removed from the solar irradiance. Detector performance and stability lies at the heart of SOLSTICE experimental success. The SOLSTICE detectors are Hamamatsu R2078 PhotoMultiplier Tubes (PMTs). We have developed an integrated PMT package [PMT, PMT housing, (mu) -metal magnetic shield, high voltage divider, and pulse-amplifier discriminator (PAD)] that will achieve our performance objectives. We report here on both the design of the integrated detector package and the laboratory measurements of the operational lifetime performance characteristics of SOLSTICE detectors. These include pulse height distribution, quantum efficiency, photocathode surface uniformity, and magnetic susceptibility.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Virginia Ann Drake, William E. McClintock, Richard A. Kohnert, Thomas N. Woods, and Gary J. Rottman "Photomultiplier tube detector performance and stability for the Earth Observing System's SOLSTICE II instrument", Proc. SPIE 4139, Instrumentation for UV/EUV Astronomy and Solar Missions, (18 December 2000); https://doi.org/10.1117/12.410538
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Quantum efficiency

Magnetism

Photomultipliers

Information operations

Sensor performance

Cesium

RELATED CONTENT

CVD diamond for beta particle detection in a gamma ray...
Proceedings of SPIE (September 13 2018)
Heading error in an alignment-based magnetometer
Proceedings of SPIE (May 23 2011)
Fluxgate magnetometers
Proceedings of SPIE (September 18 2003)
Compact and low-cost fiber optic thermometer
Proceedings of SPIE (June 16 1997)

Back to Top