Paper
18 April 2000 Visual servoing for automatic and uncalibrated percutaneous procedures
Michael H. Loser, Nassir Navab, Benedicte Bascle, Russell H. Taylor
Author Affiliations +
Abstract
Visual servoing is well established in the field of industrial robotics, when using CCD cameras. This paper describes one of the first medical implementations of uncalibrated visual servoing. To our knowledge, this is the first time that visual servoing is done using x-ray fluoroscopy. In this paper we present a new image based approach for semi-automatically guidance of a needle or surgical tool during percutaneous procedures and is based on a series of granted and pending US patent applications. It is a simple and accurate method which requires no prior calibration or registration. Therefore, no additional sensors, no stererotactic frame and no additional calibration phantom is needed. Our techniques provides accurate 3D alignment of the tool with respect to an anatomic target and estimates the required insertion depth. We implemented and verified this method with three different medical robots at the Computer Integrated Surgery (CIS) Lab at the Johns Hopkins University. First tests were performed using a CCD-camera and a mobile uniplanar x-ray fluoroscope as imaging modality. We used small metal balls of 4 mm in diameter as target points. These targets were placed 60 to 70 mm deep inside a test-phantom. Our method led to correct insertions with mean deviation of 0.20 mm with CCD camera and mean deviation of about 1.5 mm in clinical surrounding with an old x-ray imaging system, where the images were not of best quality. These promising results present this method as a serious alternative to other needle placement techniques, which require cumbersome and time consuming calibration procedures.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Michael H. Loser, Nassir Navab, Benedicte Bascle, and Russell H. Taylor "Visual servoing for automatic and uncalibrated percutaneous procedures", Proc. SPIE 3976, Medical Imaging 2000: Image Display and Visualization, (18 April 2000); https://doi.org/10.1117/12.383049
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications and 3 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Visualization

X-rays

CCD cameras

3D acquisition

Calibration

Surgery

X-ray imaging

Back to Top