Paper
5 June 1998 Design and realization of a fiber delivery system for the continuous-wave and pulsed CO2 laser
Author Affiliations +
Proceedings Volume 3262, Surgical-Assist Systems; (1998) https://doi.org/10.1117/12.309463
Event: BiOS '98 International Biomedical Optics Symposium, 1998, San Jose, CA, United States
Abstract
Recently, hollow wave guides (HWG) have become available enabling CO2 beam delivery for treatments in less accessible parts of the human body. In this study, an IR fiber delivery system was designed which can easily be attached to and removed from an existing medical laser without interference with its normal functionality. The system accepts SMA terminated HWG with an inner diameter as small as 320 μm . Measurements were performed with 320- 1000 micrometers diameter HWG. The coupling losses were around 10 percent. Transmission losses were up to 2.5 dB/m and depended on the bending radius of the fiber. The fibers tolerated pulse energies up to 400 mJ with peak powers of 800 W and an average power of 10 W. The beam quality was preserved during transmission. Deposited the losses, the output energy easily exceeded the threshold for tissue ablation. The IR fiber delivery system was successfully used in a clinical setting. The flexible 320 μm fiber was introduced through the 1 mm working channel of a 2.3 mm fiber-endoscope with a 90 degree bendable tip. Tissue was effectively ablated with pulses up to 300 mJ out of the fiber. To prevent damage due to pollution of the coating inside the HWG, it will be necessary to close the distal end of the fiber by an IR transmitting material. The IR fiber delivery system has shown to be practical in clinical use without interference with the normal functionality of the CO2 laser. The system enables endoscopic application of CW and pulsed CO2 laser light.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ad de Snaijer, Rudolf M. Verdaasdonck, Matthijs C. M. Grimbergen, and Christiaan F. P. van Swol "Design and realization of a fiber delivery system for the continuous-wave and pulsed CO2 laser", Proc. SPIE 3262, Surgical-Assist Systems, (5 June 1998); https://doi.org/10.1117/12.309463
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Carbon dioxide lasers

Fiber lasers

Coating

Waveguides

Shape memory alloys

Surgery

Carbon dioxide

RELATED CONTENT

Ball-ended medical fiber light guides
Proceedings of SPIE (August 05 1997)
SwiftLase a new tool for laser assisted uvula palatoplasty...
Proceedings of SPIE (September 07 1994)
CO2 laser myringoplasty
Proceedings of SPIE (March 02 2010)
Clinical effects of CO2 laser on equine diseases
Proceedings of SPIE (October 15 2002)

Back to Top