20 April 1998 Comparison between cw and pulsed laser calorimetric measurement at 1.06 μm
Ulrike Broulik, Peter Meja, Bernhard Steiger
Author Affiliations +
Abstract
The ISO 11 551 standard for laser calorimetric measurement does not define the temporal regime of the laser irradiation. Comparative experiments were carried out using a cw and pulsed laser beam at 1.06 micrometers wavelength. The pulsed laser parameters are 10 Hz pulse repetition rate and 12 ns pulse length. Nearly the same average power, irradiation time and beam spot size are chosen to ensure the comparability of cw and pulsed irradiation procedure. In this paper the measured temperature curves and calculated absorbencies for different samples are presented.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ulrike Broulik, Peter Meja, and Bernhard Steiger "Comparison between cw and pulsed laser calorimetric measurement at 1.06 μm", Proc. SPIE 3244, Laser-Induced Damage in Optical Materials: 1997, (20 April 1998); https://doi.org/10.1117/12.306983