31 December 1997 Spectralon diffuser calibration for MERIS
Carina Olij, Jos Groote Schaarsberg, Henri G.C. Werij, Erik Zoutman, Gilles Baudin, Beatrice Chommeloux, Jean-Loup Bezy, Georges Gourmelon
Author Affiliations +
Proceedings Volume 3221, Sensors, Systems, and Next-Generation Satellites; (1997) https://doi.org/10.1117/12.298122
Event: Aerospace Remote Sensing '97, 1997, London, United Kingdom
Abstract
One of the key payload instruments of ESA's ENVISAT polar platform is the medium resolution imaging spectrometer (MERIS), aiming at improved knowledge of our planet in the fields of bio-optical oceanography, and atmospheric and land surface processes. MERIS, which is built under responsibility of Aerospatiale, will monitor the solar irradiation scattered by the Earth by employing five cameras which simultaneously record data in 15 visible and near-infrared programmable spectral bands with very low degree of polarization sensitivity. The combined field-of-view of the five cameras spans a range of 68.5 degrees. Crucial for obtaining the desired high accuracy during a four-years lifetime, is the on- board calibration unit. This calibration unit contains a set of Spectralon diffusers, which were manufactured having in mind excellent in-flight stability as well as spectral and spatial uniformity. Preflight calibration of the Spectralon diffusers was carried out at TNO-TPD. This calibration includes the measurement of the bidirectional reflectance distribution function (BRDF) for applicable angles and wavelengths, i.e., while varying angle of incidence, angle of observation, observation area on the elongated diffusers, wavelength and polarization. The diffuser calibration was performed in a class 100 cleanroom. For these measurements the TPD calibration facility, which is described in detail, has been adapted, so that it now has five geometrical degrees of freedom. Detectors have been optimized to minimize stray light. Due to extensive commissioning of the calibration setup the absolute error (1 sigma) of these measurements amounts to less than 0.5%; relative errors are in the 0.3 - 0.4% range.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Carina Olij, Jos Groote Schaarsberg, Henri G.C. Werij, Erik Zoutman, Gilles Baudin, Beatrice Chommeloux, Jean-Loup Bezy, and Georges Gourmelon "Spectralon diffuser calibration for MERIS", Proc. SPIE 3221, Sensors, Systems, and Next-Generation Satellites, (31 December 1997); https://doi.org/10.1117/12.298122
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Diffusers

Spectral calibration

Bidirectional reflectance transmission function

Cameras

Polarization

Image resolution

RELATED CONTENT

Calibration and early results of MERIS on ENVISAT
Proceedings of SPIE (April 08 2003)
Medium resolution imaging spectrometer
Proceedings of SPIE (September 13 1994)
Radiometric calibration of MERIS
Proceedings of SPIE (October 12 2011)
MERIS FM performances
Proceedings of SPIE (October 03 1998)
Polarization scattering from a Spectralon calibration sample
Proceedings of SPIE (September 13 2007)
MERIS 1st year: early calibration results
Proceedings of SPIE (February 02 2004)

Back to Top