Paper
15 October 1997 PN-CCD camera for XMM: performance of full frame and window operating modes
Elmar Pfeffermann, Heinrich W. Braeuninger, Ulrich G. Briel, Konrad Dennerl, Frank Haberl, Gisela D. Hartner, Norbert Meidinger, Claus Reppin, Lothar Strueder, Joachim E. Truemper, Edgar Bihler, Eckhard Kendziorra, Baerbel Kretschmar, Bernhard Pflueger, Peter Holl, Josef Kemmer, Heike Soltau, Christoph von Zanthier
Author Affiliations +
Abstract
The pn-charge coupled device (pn-CCD) camera was developed as one of the focal plane instruments for the European photon imaging camera (EPIC) on board the x-ray multi mirror (XMM) mission. The homogeneously sensitive detector consists of four quadrants of three pn-CCDs each, which are integrated on a single silicon wafer. Each CCD has an area of 10 mm by 30 mm divided into 64 by 200 pixels with a depletion depth of 280 micrometers. Altogether the sensitive area is 60 mm by 60 mm. In the standard imaging mode (full frame mode) the CCDs are read out sequentially every 70 ms. In addition, different window modes allow imaging of brighter sources by restricting the detector area and reducing the integration time down to 6 ms. We have tested one quadrant of the EPIC pn-CCD camera at line energies from 0.52 keV to 17.4 keV at the long beam test facility PANTER in focus of the qualification mirror module for XMM as well as in a homogeneous x-ray beam. In this paper we describe the tests in the different imaging modes and report on the performance.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Elmar Pfeffermann, Heinrich W. Braeuninger, Ulrich G. Briel, Konrad Dennerl, Frank Haberl, Gisela D. Hartner, Norbert Meidinger, Claus Reppin, Lothar Strueder, Joachim E. Truemper, Edgar Bihler, Eckhard Kendziorra, Baerbel Kretschmar, Bernhard Pflueger, Peter Holl, Josef Kemmer, Heike Soltau, and Christoph von Zanthier "PN-CCD camera for XMM: performance of full frame and window operating modes", Proc. SPIE 3114, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy VIII, (15 October 1997); https://doi.org/10.1117/12.283764
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Charge-coupled devices

Sensors

X-rays

Cameras

Mirrors

Calibration

Semiconducting wafers

RELATED CONTENT

PN-CCD detector for XMM and ABRIXAS
Proceedings of SPIE (October 22 1999)
EPIC pn CCD detector aboard XMM Newton status of...
Proceedings of SPIE (February 03 2004)
Status of the calibration of the EPIC pn camera onboard...
Proceedings of SPIE (February 03 2004)
PN CCD camera for XMM and ABRIXAS design of...
Proceedings of SPIE (October 22 1999)
Recent developments for the AXAF CCD imaging spectrometer
Proceedings of SPIE (November 19 1993)

Back to Top