30 May 1997 Continuous flow fluorescence based immunosensor for the detection of explosives and environmental pollutants
Paul T. Charles, John C. Bart, Linda L. Judd, Paul R. Gauger, Frances S. Ligler, Anne W. Kusterbeck
Author Affiliations +
Abstract
A continuous flow fluorescence based immunosensor has been developed at the Naval Research Laboratory as an inexpensive, field portable device to detect environmental pollutants. Detection of environmental pollutants such as explosives [e.g. trinitrotoluene (TNT) and hexahydro-1,3,5 trinitro- 1,3,5-triazine (RDX)[ and polychlorinated biphenyls (PCBs) have been achieved at low level concentrations. The continuous flow immunosensor (CFI) employs antibodies as recognition elements for specific antigens. Antibodies specific for the environmental pollutants of interest are covalently immobilized on a solid support matrix. Subsequent saturation of the antibody-support complex with a fluorescence analog (i.e. cyanine dye) of the pollutant completes the sensor matrix. The derivatized matrix is prepacked into a micro column with a continuous flow stream of buffer that removes nonspecifically bound fluorescent analog. After a stable baseline is obtained sample injections of the desired pollutant (PCBs, TNT, RDX, etc.) into the flow stream displaces the fluorescence analog from the immobilized antibody on the solid support. A signal response over background from the displaced fluorescence analog is measured and integrated by an in-line fluorometer. Dose response curves reveal the lowest limit of detection for TNT and RDX is 20 ppb (parts-per-billion). Detection limits for PCBs is slightly higher at 1.0 ppm (part-per-million). Results from field trials conducted at two military bases, Umatilla Army Depot (Hermiston, Ore.) and Site F and A at Naval SUBASE Bangor (Bangor, Wash.) demonstrated the capabilities of the immunosensor in performing on-site field analysis in groundwater and soil leachate matrices.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Paul T. Charles, John C. Bart, Linda L. Judd, Paul R. Gauger, Frances S. Ligler, and Anne W. Kusterbeck "Continuous flow fluorescence based immunosensor for the detection of explosives and environmental pollutants", Proc. SPIE 3105, Chemical, Biochemical and Environmental Fiber Sensors IX, (30 May 1997); https://doi.org/10.1117/12.276137
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Analog electronics

Explosives

Luminescence

Statistical analysis

Environmental sensing

Soil contamination

Pollution detection

Back to Top