Paper
13 May 1997 Status of optics on the OMEGA laser after 18 months of operation
Author Affiliations +
Abstract
The 60-beam OMEGA laser has sustained approximately 1000 target shots without significant damage to the optics. Approximately 3000 optics on the OMEGA laser system were closely monitored during their installation, and inspections continue throughout the operation of the system. A review of the condition of these optics at each stage of the laser and a summary of the peak incident fluences are presented. The most severe damage on OMEGA is seen on the input, fused- silica, spatial filter lenses. Since these optics are under vacuum, inspection of damaged lenses occurs on a more frequent cycle to track the growth of the defect and to maintain the system's safety. An optic is replaced well before massive failure is expected to occur. Other optics on the system that exhibit different types of damage are BK7 spatial filter lenses, focus conversion crystals, primary pickoff lenses, calorimeters, and liquid-crystal optics. Laser glass and development optics such as distributed phase plates are not covered in this review.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Amy L. Rigatti and Douglas J. Smith "Status of optics on the OMEGA laser after 18 months of operation", Proc. SPIE 2966, Laser-Induced Damage in Optical Materials: 1996, (13 May 1997); https://doi.org/10.1117/12.274262
Lens.org Logo
CITATIONS
Cited by 9 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Lenses

Spatial filters

Coating

Beam splitters

Laser induced damage

Inspection

Mirrors

Back to Top