This paper contains inspection results for a carbon epoxy plastic reference specimen with TeflonTM inserts. A long-pulse heating technique and AGEMA-900 IR imager have been used. Results are presented as a set of twenty-two images including a source image, normalized image, timegram, depthgram, tomogram presented as B&W and color hard-copies, as well as live images on a color monitor. This set of data has been exhibited to operators (experts or not) together with the set of rules for detecting defects. Obtained data are processed statistically and compared with true defect locations. The Tanimoto criterion is used for data comparison. Recommendations on the best image processing technique, as well as on the best form of data presentation, are given.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Vladimir P. Vavilov, Paolo Giulio Bison, and Ermanno G. Grinzato "Statistical evaluation of thermographic NDT performance applied to CFRP", Proc. SPIE 2766, Thermosense XVIII: An International Conference on Thermal Sensing and Imaging Diagnostic Applications, (15 March 1996); https://doi.org/10.1117/12.235396