Paper
16 October 1995 Performance of the large-area position-sensitive x-ray detector of the SAX wide-field camera
Willem A. Mels, H. B. Buurmans, R. Henderikus Jager, P. Lowes, A. P. Naber, A. Rook, R. Schuurhof, A. C. Brinkman
Author Affiliations +
Abstract
A large area position sensitive x-ray detector system has been developed and built for the wide field cameras aboard the SAX satellite. This satellite will be launched early 1996. The detector is a sealed multiwire position sensitive proportional counter filled with 2 bar xenon gas. It has a sensitive area of 256 multiplied by 256 mm. The system covers the photon energy range of 1.8 to 30 keV. The position resolution is better than 0.5 mm for energies lower than 10 keV. The background rejection efficiency is better than 95%. The performance of the detector system is described. Pre-flight test and calibration results are presented.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Willem A. Mels, H. B. Buurmans, R. Henderikus Jager, P. Lowes, A. P. Naber, A. Rook, R. Schuurhof, and A. C. Brinkman "Performance of the large-area position-sensitive x-ray detector of the SAX wide-field camera", Proc. SPIE 2517, X-Ray and EUV/FUV Spectroscopy and Polarimetry, (16 October 1995); https://doi.org/10.1117/12.224916
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Calibration

Cameras

Aluminum

Electronics

Satellites

X-ray detectors

RELATED CONTENT