Paper
25 December 1979 Vibration Insensitive Laser Unequal Path Interferometer (LUPI) Test
Chuck Hardesty
Author Affiliations +
Abstract
A 24 inch diameter segment of a 60 inch diameter, 10 meter focal length parabolic mirror was fabricated at Space Optics Research Labs. Due to the long focal length, a standard null test using a 24 inch flat could not be set up on our 12 foot air table. The test was set up in a long room which was subject to vibrations. A modification was made to a LUPI (Laser Unequal Path Interferometer) to allow the collimated reference beam to follow approximately the same path as the test beam. Adjustable flat mirrors for the reference beam were attached to the sides of the mounts for the parabola and flat. This combination allowed the r-,f,erence beam to "follow along" and pick up the same vibrations as the test beam. Good high contrast fringes were produced by this method. This paper will describe the test procedure and equipment. Additional problems of temperature, turbulence, and coherence will be summarized.
© (1979) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Chuck Hardesty "Vibration Insensitive Laser Unequal Path Interferometer (LUPI) Test", Proc. SPIE 0192, Interferometry, (25 December 1979); https://doi.org/10.1117/12.957842
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mirrors

Interferometers

Turbulence

Interferometry

Monochromatic aberrations

Astronomical imaging

Collimation

Back to Top