Paper
6 June 1978 A High Performance 8 TO 12 μm (Hg,Cd)Te 72-Element Detector Array
James B. Gilpin, John Roschen, Stephen R. Hampton, M. John Kniffin
Author Affiliations +
Proceedings Volume 0132, Utilization of Infrared Detectors; (1978) https://doi.org/10.1117/12.956067
Event: 1978 Los Angeles Technical Symposium, 1978, Los Angeles, United States
Abstract
A high performance 8 to 12 µm 72-element (Hg,Cd)Te detector array has been built for an advanced difffaction-limited serial-scanned FLIR system. The avelzage peak detect it for the array is 1.7 x 1011 cm Hz 1/2 /W which results in a cumulative detectivity (~ rn D avg.) of 1.4 x 1012 cm Hz 1/2 /W . The cumulative detectivity controls system sensitivity. The cumulative D* for this array is over 2.3 times higher than a modular FLIR array with 180 elements and a better than average peak detectivity of 4.5 x 1010 cm Hz 1/2 /W or a cumulative detectivity of 0.6 x 1010 cm Hz ½/W.
© (1978) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
James B. Gilpin, John Roschen, Stephen R. Hampton, and M. John Kniffin "A High Performance 8 TO 12 μm (Hg,Cd)Te 72-Element Detector Array", Proc. SPIE 0132, Utilization of Infrared Detectors, (6 June 1978); https://doi.org/10.1117/12.956067
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Forward looking infrared

Detector arrays

Sensors

Curium

Infrared detectors

Lead

Platinum

RELATED CONTENT


Back to Top