Abstract
By combining high beam quality picosecond pulsed optical parametric amplifiers at 2.94 μm with Rapid Evaportive Ionisation Mass Spectrometry (REIMS), we have demonstrated record spatial pixel resolutions for ambient mass spectrometry (MS) imaging of < 10 μm. In this contribution, we introduce our work in this area, demonstrating the platform workflow and highlighting recent results of metabolic imaging at the single cell resolution level.
Conference Presentation
(2024) Published by SPIE. Downloading of the abstract is permitted for personal use only.
Robert T. Murray, Ronan A. Battle, Daniel Simon, Yuchen Xiang, Kenneth Robinson, Samuel F. Azevedo Magalhães, Yu Wang, Timothy H. Runcorn, and Zoltan Takats "Visualizing metabolites at the cellular level: advancements in 3-micron laser desorption mass spectrometry imaging", Proc. SPIE 12836, Optical Biopsy XXII: Toward Real-Time Spectroscopic Imaging and Diagnosis, 1283602 (12 March 2024); https://doi.org/10.1117/12.3008405