1.INTRODUCTION1.1OASIS – Science Goals and ObjectivesThe Orbiting Astronomical Satellite for Investigating Stellar Systems (OASIS) is a 20-meter class space observatory that will perform high spectral resolution observations at terahertz frequencies. The observatory will scout for biogenic molecules within hundreds of protoplanetary disks and will have sufficient sensitivity to explore the role water plays in the evolution of planetary systems.1 1.2Geometrical Shape of Pneumatic MembranesThe immediate predecessor to this paper describes the nature of pressurized circular membranes.2 A pressurized ideal isotropic membrane produces a spherically aberrated shape called a Hencky Curve surface.3 If the inflated assembly is constructed from real films for space applications such as polyimide, the pressurization generates a biconic which owes its excess coma and astigmatism to the film’s mechanical anisotropy. At lower inflation pressures, wrinkles sprout from perimeter of the reflector, introducing higher order spatial frequency errors.4 These artifacts rapidly diminish at higher pressure because the stress experienced across the entire aperture grows more uniform in all directions under pneumatic loading, shown in Figure 1. The large range of possible measurable surface shape is what motivates our use of phase-measuring deflectometry. Our previous paper described how deflectometry is fast, non-contact, and can obtain full-aperture measurements of multiple inflation pressures from a single setup configuration. The previous paper also described the difficulties in measuring inflatable UUTs (Unit Under Test) with deflectometry. One discretion is that the accuracy of geometric calibration must be commensurate with the desired accuracy of surface reconstruction. Miscalibration of one reference coordinate of the screen or camera by several microns introduces several hundred nanometers of power and astigmatism each into the final UUT surface reconstruction. This error exceeds the error budget of visible wavelength optics, but for terahertz optics, the error lies well below λ/8 rms for typical calibration uncertainties and will be demonstrated for 9 DOFS (degrees of freedom) of perturbation via a deflectometry measurement and reconstruction simulation. 1.3Thermal Vacuum Chamber TestingTVAC testing is a regular milestone in space flight hardware development. Emulation of the conditions of space is important to predict the behavior of hardware already demonstrated on land. Since 2019, tests of the 1m OASIS prototype at RTP (room temperature and pressure) have demonstrated focal length control as a function of internal pressure. Shape behavior is highly linear. Power increases and astigmatism decreases with incremental inflation.2 The next phase of characterizing the novel inflatable antenna was marked as assessed shape behavior under low temperature and pressure. A 1m OASIS prototype was measured through a clear 10” aperture acrylic TVAC chamber window. A custom deflectometer was aligned to this window, obtaining a surface reconstruction signal for the majority of the 1m aperture. The full optomechanical mounting scheme for the 1m mirror is described in detail in our sister paper.5 1.4Metrology Advances and Experiments for Membrane AntennaeOur presented analyses and simulations demonstrate the suitability of deflectometry as applied to terahertz inflatable membrane reflector characterization. Our 150 mm-scale model was examined for sensitivity to calibration error using a custom deflectometry simulator written in Zemax OpticStudio Non-Sequential and Matlab. An experimental configuration for absolute metrology with deflectometry using the N-Rotations technique acquired reconstructable signal over eight clocked positions. Finally, some key measurements for the 1m-scale OASIS primary antenna prototype in TVAC are provided. Shape measurements, taken in July 2021, tracked the dynamic slope evolution for a central clear aperture area. 2.THEORY AND SIMULATION FOR DEFLECTOMETRY SHAPE MEASUREMENT2.1Differential Deflectometry TheoryHistorically, the challenge to global accuracy in deflectometry measurements has been accurate geometric calibration.6 Calibration consists of finding and fitting the camera, test surface, and spatial light source, and , into an accurate digital representation of the physical test environment. One instructive representation of a deflectometry slope calculation, valid for slow optics, is derived from Ritter’s expression for surface slopes, Sy, in the single directional case in y (a similar calculation follows in the x-slopes, Sx). 7 Here, the direction z is parallel to the optical axis of a spherical optic, the direction y in the meridional plane, and the direction x in the sagittal. If slope at each sampled point across the optic is calculated in this way, it can be observed that a mismeasurement of the lateral coordinates or of produces slope deviation in the final slope calculation for Sy but not Sx. Surface reconstruction with this imprecise calibration parameter is akin to miscalculating more power in the meridional plane but not additional power in the sagittal; hence, excess asymmetric shape is embedded into the deflectometry measurement across the full aperture. Similarly, a miscalibration of longitudinal coordinates or produces equal slope deviation in both x and y directions and produces deviation from the surface’s true power. Deflectometry’s susceptibility to calibration errors in absolute measurements is well known in the metrology community, but equally known is that the subtraction of two deflectometry measurements that use identical calibration parameters produces a high-fidelity shape difference measurement.8 If one’s objective is to compare the shape of an inflatable UUT when internal pressure, external environmental temperature and pressure, or even internal gas composition are altered, differential deflectometry is well-poised to measure the induced shape difference. The sensitivity and accuracy of the differential variant allowed our team to precisely observe shape changes for several static environmental setpoints and even after controlled puncture in TVAC. 2.2Shape Uncertainty due to Calibration TolerancesWe also explored methods to constrain shape error in absolute measurements arising from geometric calibration error. While interferometry requires a physical null to be manufactured to within a wave of the test optic’s true shape, deflectometry requires a virtual null, or a low-order model of the ideal design surface. The assumption of an ideal model for surface calculation is not redundant with the result of an actual deflectometry test; deflectometry measurement leverages the law of reflection to determine the path of each ray from the illumination source, deflected by the UUT, and into the camera. When accurate calibration parameters are fed into the processing algorithm, accurate slopes sampled across the UUT aperture are obtained. In the integrated surface height maps, the mid-spatial and high-spatial frequencies of the UUT’s true shape are revealed, which were not modeled in the virtual null.9 In a stricter case where we assume that the low-order surface model (i.e. RoC, radius of curvature) is not precisely known, we can estimate the bounds of surface error induced by the assumed model. To do this, we created a deflectometry measurement data acquisition simulator. Between a pinhole camera, a biconic UUT, and LCD screen in Zemax OpticStudio Non-Sequential, the behavior of deflected rays between deflectometer hardware components was simulated following the laws of geometrical optics. In Matlab, the coordinates for ~4 million ray paths and 12 million ray-surface intercepts are extracted and down-sampled to a uniformly spaced 999 x 999 pixel grid. This process obtains information as if a physical deflectometry measurement had been performed, used calibration data (perfect or erroneous) specified by a user, and was handled with our regular deflectometry processing pipeline. In Figure 2, perfect calibration parameters set was fed into the processing algorithm, and the resultant sag map was decomposed into the Noll Zernike polynomial set.10 Measurement simulations with the perfect calibration parameters showed < 1 nm RMS reconstruction accuracy for both a f/2.8 sphere (D = 150 mm) and a biconic optic (RoCx = 850 mm, RoCy = 700 mm). The simulator has the flexibility to use UUTs with arbitrary biconic radii and arbitrary Zernike polynomial shape terms up to Z37. With confidence that the simulator could accurately simulate the effects of miscalibration, we used the new tool to show the influence of erroneous calibration on global surface reconstruction, one calibration parameter at a time. When nine translational rigid body degrees of freedom are perturbed by 10 mm in either direction, only primary astigmatism and power are noticeably induced. No resultant erroneous shapes beyond Z12 had a magnitude higher than tens of nanometers, as shown in Figure 3. Next, we inserted an erroneous spherical shape to act as the virtual null surface for calculation during processing. Modeling the biconic as a sphere of some varying RoC throughout the study, our deflectometry process simulation produced no erroneous Zernike polynomial coefficients higher than 12; above Z6, no coefficient appeared above 10 nanometers. However, high astigmatism (Z6) was observed, shown in Figure 4. A 150 um Z6 coefficient blows past the desired error budget and remains insensitive to the choice of spherical RoC due to the true optic being astigmatic. To address the low order shape issue, we can use a simple experimental 4f conjugate imaging test to determine the membrane reflector’s possible range of focal lengths. A small source illuminates the inflated membrane close to the UUT’s mechanical axis, and is then moved backwards in the z-direction until the image of that source is coplanar with the source origin. Now that the sagittal and tangential foci are estimated, and we can use these distances as RoCx and RoCy to feed into the calibration parameters as the low-order shape. The uncertainty range of the visually ascertained RoCs were easily within ± 10 mm. Using estimated biconic radii of curvature on the magnitude of 10 mm for the previous test case, we produced the following surface reconstruction errors (Figure 5) when both estimated RoCs had errors of the same sign and magnitude. 2.3Absolute Metrology TheoryIn interferometric measurements, measurement error in the surface height arises from height errors in the null reference optic. This height error can be represented as a sum of Zernike polynomials, divided into two categories - rotationally symmetric terms (k = 0) and rotationally asymmetric terms (k ≠ 0). When a UUT is clocked during measurement, neither the symmetric nor asymmetric null errors rotate with the clocking of the optic; only the true surface shape of the test optic rotates. This difference is manifested in a slightly different interferogram from the previous clocking position due to the static null and rotated UUT. In absolute interferometry literature, the N-Rotations technique takes advantage of the induced difference by making N equally spaced measurements at clocked positions θ = 360/N.11 After N measurements are made, the obtained height maps are digitally unrotated to the common position θ0 = 0, and an average is taken of all the maps. When they are digitally unrotated and averaged over N rotations, for all k < N, excluding k = 0.12 For example, for N = 6, six measurements taken 60 degrees apart, digitally unrotated, and averaged, removes all asymmetric error up to Z37. The highest harmonic order represented up to that Z37 is k = 5. The k-symmetry of the azimuthal terms allows all of the rotationally asymmetric error up to Z37 to simply cancel out. Unfortunately, rotationally symmetric error terms are immune to this technique. The practical use case for N-Rotations in interferometry is usually when the desired accuracy of measurement is on par with the accuracy of the manufactured null. Surface error across the aperture optic still must be within a fraction of a wavelength of the null optic for all clocked UUT positions, or else no processable interferogram signal will be present at sub-aperture UUT locations that exceed that height difference. For deflectometry, this height difference limitation for clocked positions is less inhibiting since a broad range of UUT positions can still capture a full reconstruction signal.13 A simulation of the N-Rotations test using an erroneous spherical surface model shows the recovery of the previous biconic shape down less than 200 nm RMS. In the case that near-perfect calibration of an optic is not assumed, we can use the N-Rotations technique to remove remaining systematic error. In Figure 6, an extreme UUT with 850 microns of Z4, and 50 microns of Z5 and Z6, and 3 microns of every single Zernike up to 37 was used in the virtual simulator for 8 rotated measurements. Calibration of all lateral parameters up was offset by +20 mm. The digital unrotation process reduced microns of the holistic induced calibration error down to less than 100 nm. 3.DEFLECTOMETRY-BASED METROLOGY SYSTEMS3.1Small-Scale Membrane Assembly Design, Manufacturing, and PreparationWe constructed a 150 mm antenna membrane assembly using clear and reflective mylar (both 1 mil thick), and clamped them between three Nylon-12 flanges. An ‘undulated’ double O-Ring design was present on each side to improve sealing performance, and double the number of flange bolts from previous prototypes to better help seal this assembly. The assembly was inflated until its medial radius of curvature was 800 mm. Then, the membrane was mounted atop a large Klinger motorized stepper stage, whose clocking resolution was 1.2 arcminutes. A 12.9” iPad Pro (#A1670) and PointGrey camera (FL3-U3-13Y3M-C) were used to measure the optic. The deflectometry configuration was set for 8 different clocking positions, because fewer digital interpolation artifacts are induced when digitally rotating obtained surface maps at multiples of 45 degrees. The full configuration is shown in Figure 7 and will be tested in the near future. 3.2TVAC Test for OASISFor TVAC testing, the 1 m UUT was oriented with its mechanical axis parallel to the inside the TVAC chamber’s cylindrical axis. This UUT is identical to that of the previous tested 1 m prototype, but both mylar sheets were replaced with fresh 3-mils thick material. Behind the inflated UUT assembly, a fixed mechanical datum consisting of three spherical tooling balls was used for physical reference in proximity to the UUT vertex. Outside the chamber, a custom vacuum ready inflation control unit provided by FreeFall Aerospace maintained the internal UUT pressure to a resolution of 10 Pa. The internal pressure was nominally set to 520 Pa (0.075 Psi) relative to the chamber-controlled environmental pressure, which ranged from atmospheric (101325 Pa) to near-vacuum (0.11 Pa). A deflectometer, shown in Figure 8, was mounted to TVAC window and aligned after the UUT was situated within the chamber for testing. This instrument consisted of a 12.9” iPad Pro (#A2378) illumination source, a Point Grey monochrome camera (FL3-U3-13Y3M-C) with a f = 12 mm lens, and machined aluminum baseplates for mounting. The camera and screen were oriented parallel to the 10” diameter TVAC window. During testing, the first Fresnel reflection at the acrylic window interface was faint enough to not significantly reduce signal contrast at the deflectometry camera detector. The entire setup is depicted in Figure 9. 4.EXPERIMENTAL TVAC RESULTS4.1Repeatability Measurement Within ChamberTesting took place over the span of one week in early July at the Northrop Grumman Space Systems facility in Redondo Beach. A total of 80 surface measurements were taken of the same surface, subject to a variety of environmental setpoints within TVAC. At each fresh inflation of the membrane, the membrane vertex was brought into contact with the rear mechanical datum and then the external pressure control unit stepped back inflation pressure by 10 Pa until the surface no longer contacted the mechanical datum. When tested between successive runs, the peak-to-valley surface difference between three measurements spaced one minute apart, was only up to 4 microns. Differences in surface measurement results manifested mostly at the edge of the aperture, where wrinkles form. For an Argon gas fill, an internal pressure of 700 Pa, TVAC chamber pressure of 0.11 Pa, and chamber temperature of 137K, the total RMS difference across the surface was about 200 nanometers, shown in Figure 10. 4.2Internal Fill Gas CyclingOur protocol then cycled the fill gas. Gases were injected into the membrane assembly through a port in the central tensioning ring, and later evacuated through a diametrically opposed outlet port. Helium was injected into the membrane first, followed by Argon, and then Xenon. Deflation and re-inflation with each gas were planned to be repeated several times to improve gas concentration but in practice, very slow fill and vacuum speed through the small, long gauge feed tube limited our ability to repeat the vacuum/fill cycle. As a result, the fill gas in the inflatable was never pure. The differential measurements between surface maps of each membrane inflated by a different gas are plotted in Figure 11. Deflectometry measurements captured small changes in shape for the same ROI within several microns PV at each gas interchange, each ~30 minutes apart. 4.3Induced Thermal Gradient by Overhead Radiation SourceDuring part of the TVAC test, an overhead heat source (or ‘Artificial Sun’) illuminated the membrane assembly. The source was positioned closest to the aperture’s 12 O’ Clock position (north). Chamber temperature was set to T = 142K and pressure was at 0.11 Pa was enforced. Starting at 10:04 AM, the radiation source was activated and the reflective mylar surface began warming. Four T-type thermocouples were attached at the four cardinal points near the periphery of the front and back membranes. For the rear reflective surface, the north T-type thermocouple for the gained thermal energy the most rapidly because it was closest to the radiation source. The southern thermocouple measured the next highest average temperature, while the eastern and western thermocouples were in between. The distribution of temperatures between the four thermocouples after a long period of time is a function of chamber geometry and radiative transfer properties. For example, the cylindrical TVAC geometry has an elevated, sliding rectangular base for mounting. This feature, rising from the floor of the chamber, breaks azimuthal geometry and allows different equilibrium temperatures to be reached between the top and bottom of the 1m UUT assembly. In Figure 12, the temperatures of all four rear thermocouples are plotted. Throughout the test, temperature was T = 142K and chamber pressure was P = 0.11 Pa. In the final half hour, the temperature of the north thermocouple indicated a change of 2K. In Figure 13 each differential map shows the change in shape from the initial surface captured from 10:44 AM, showing the difference in shape from each preceding map. The evolution of the thermal gradient can be visually ascertained but also calculated. The RMS difference from the first two subplots grew to ~2 μm by subplot 8. By 11:00 AM, the thermal expansion of the mylar was sufficient to bring the concave surface in contact with the mechanical datums. 4.4Surface Puncture TestThe last segment of our test protocol was a puncture test shown in Figure 14 - 15. A feature of Northrop’s TVAC chamber added for this test is an externally-controllable arm. The mechanical actuator wields a thin needle, which moves in an arc to pierce a hole into the back reflective membrane. The spatial location was chosen at the north cardinal position near the aperture edge of the membrane assembly. Figure 14 reveals the reconstruction signal with no puncture, with puncture 1 minute later, and puncture 2.5 minutes later. The shadow in the third subplot indicates that the slope is steep enough to exceed the dynamic slope measurement range of the deflectometer configuration. Interesingly, at almost 4 minutes from puncture, the assembly cyclically recovered from the initial pressure ripple such that full central aperture measurements can be made again. Figure 15 shows full center aperture measurements whenever the unmeasurable shadow disappears. Interestingly, the southern thermocouple becomes a heightened node after puncture, moving closer to the deflectometer. To observe the surface effects of the main subaperture, the radius of the common analysis aperture was decreased by 40 mm. Shape changes reflect different phases of the cyclic pressure ripple – spaced two minutes apart, the first four subfigures show differences increasing up to 10 μm PV and as low as 1.5 μm PV. The plots show surface shape subtractions from the original unpunctured surface measurement taken at 5:26:40 PM. 5.SUMMARY AND CONCLUSIONWe demonstrate methods to bound the influence of the calibration uncertainties that introduce surface reconstruction errors in deflectometry for pneumatic membranes. A deflectometry reconstruction simulator for arbitrary biconic and Zernike shapes showed generous amenability to calibration errors on the order of millimeters, under a tolerance budget dictated by the science wavelength on the order of tens of microns. A N-Rotations test was also simulated and its experimental setup will be tested in the future. Finally, TVAC testing was conducted at low-temperature, near-vacuum conditions for repeatability, gas cycling, induced thermal gradients, and puncture. The full extent of data has yet to be examined, but the reported results show a positive outlook for a larger-scale membrane, characterized at atmosphere and in TVAC. ACKNOWLEDGEMENTSThe authors would like to acknowledge the II-VI Foundation Block-Gift, Technology Research Initiative Fund Optics/Imaging Program, and Friends of Tucson Optics Endowed Scholarships in Optical Sciences for helping support the metrology research conducted in the LOFT group. We would also like to acknowledge FreeFall Aerospace in Tucson, Arizona for supplying the vacuum pressure modular pumps to maintain internal gas pressure during testing. Finally, we would like to thank the Northrop Grumman Aerospace Systems team for their incredible help during a full week of testing. REFERENCESWalker, C., Kulesa, C., Smith, I. S., Perry, W., Kim, D., Palisoc, A., Cassapakis, C., Crowe, D. and Pierce, D.,
“Orbiting Astronomical Satellite for Investigating Stellar Systems (OASIS): Following Water from the Interstellar Medium to Oceans,”
Bull. AAS,
(2019). Google Scholar
Quach, H., Berkson, J., Sirsi, S., Choi, H., Dominguez, R., Duffy, B., Lesser, D., Takashima, Y., Palisoc, A., Walker, C. and Kim, D. W.,
“Full-aperture optical metrology for inflatable membrane mirrors,”
Opt. Manuf. Test. XIII,
(2020). https://doi.org/10.1117/12.2569750 Google Scholar
Hencky, H.,
“Über den Spannungszustand in kreisrunden Platten,”
Zeitschrift für Angew. Math. und Mech., 311
–317
(1915). Google Scholar
Chandra, A. and Walker, C. K.,
“Thermally formed inflatable reflectors for space telescopes,”
2020
(2020). Google Scholar
Esparza, M. A.,
“Stressed Deformable Reflector and Pneumatic Membrane Antenna for Thermal Vacuum Terahertz Wavefront Control and Measurement,”
in Astron. Opt. Des. Manuf. Test Sp. Gr. Syst. III, SPIE—The International Society for Optical Engineering,
(2021). Google Scholar
Huang, L., Idir, M., Zuo, C. and Asundi, A.,
“Review of phase measuring deflectometry,”
Opt. Lasers Eng., 107
(August), 247
–257
(2018). https://doi.org/10.1016/j.optlaseng.2018.03.026 Google Scholar
Ritter, R. and Hahn, R.,
“Contribution to analysis of the reflection grating method,”
Opt. Lasers Eng., 4
(1), 13
–24
(1983). https://doi.org/10.1016/0143-8166(83)90003-9 Google Scholar
Kam, J.,
“Differential Phase Measuring Deflectometry for High-Sag Freeform Optics,”
(2019). Google Scholar
Huang, R., Su, P., Horne, T., Brusa, G. and Burge, J. H.,
“Optical metrology of a large deformable aspherical mirror using software configurable optical test system,”
Opt. Eng., 53
(8), 085106
(2014). https://doi.org/10.1117/1.OE.53.8.085106 Google Scholar
Noll, R. J.,
“Zernike Polynomials and Atmospheric Turbulence.,”
J Opt Soc Am, 66
(3), 207
–211
(1976). https://doi.org/10.1364/JOSA.66.000207 Google Scholar
Evans, C. J. and Kestner, R. N.,
“Test optics error removal,”
Appl. Opt., 35
(7), 1015
(1996). https://doi.org/10.1364/AO.35.001015 Google Scholar
Parks, R. E.,
“Removal of Test Optics Errors,”
Adv. Opt. Metrol. I, 0153 56
–63
(1978). https://doi.org/10.1117/12.938216 Google Scholar
Faber, C., Olesch, E., Krobot, R. and Häusler, G.,
“Deflectometry challenges interferometry: the competition gets tougher!,”
Interferom. XVI Tech. Anal, 8493 84930R
(2012). https://doi.org/10.1117/12.957465 Google Scholar
|