Paper
26 September 1989 Mechanical Collimators For EUV Spectrometers
M. Melozzi, M. Fibbi
Author Affiliations +
Proceedings Volume 1130, New Technologies for Astronomy; (1989) https://doi.org/10.1117/12.961514
Event: 1989 International Congress on Optical Science and Engineering, 1989, Paris, France
Abstract
The mechanical collimator to limit the field of view of the EUV/FUV Imaging Spectrograph Facility will be realized using a series of thin electroformed plates. In the present report the plate number and positions are computed and a procedure to test the instrument using visible light is discussed.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
M. Melozzi and M. Fibbi "Mechanical Collimators For EUV Spectrometers", Proc. SPIE 1130, New Technologies for Astronomy, (26 September 1989); https://doi.org/10.1117/12.961514