Presentation + Paper
15 March 2019 Iterative reconstruction for low dose CT using Plug-and-Play alternating direction method of multipliers (ADMM) framework
Author Affiliations +
Abstract
Concerns over the risks of radiation dose from diagnostic CT motivated the utilization of low dose CT (LdCT). However, due to the extremely low X-ray photon statistics in LdCT, the reconstruction problem is ill-posed and noisecontaminated. Conventional Compressed Sensing (CS) methods have been investigated to enhance the signal-to-noise ratio of LdCT at the cost of image resolution and low contrast object visibility. In this work, we adapted a flexible, iterative reconstruction framework, termed Plug-and-Play (PnP) alternating direction method of multipliers (ADMM), that incorporated state-of-the-art denoising algorithms into model-based image reconstruction. The PnP ADMM framework is achieved by combining a least square data fidelity term with a regularization term for image smoothness and was solved through the ADMM. An off-the-shelf image denoiser, the Block-Matching 3D-transform shrinkage (BM3D) filter, is plugged in to substitute an ADMM module. The PnP ADMM was evaluated on low dose scans of ACR 464 phantom and two lung screening data sets and is compared with the Filtered Back Projection (FBP), the Total Variation (TV), the BM3D post-processing method, and the BM3D regularization method. The proposed framework distinguished the line pairs at 9 lp/cm resolution on the ACR phantom and the fissure line in the left lung, resolving the same or better image details than FBP reconstruction of higher dose scans with up to 18 times less dose. Compared with conventional iterative reconstruction methods resulting in comparable image noise, the proposed method is significantly better at recovering image details and improving low contrast conspicuity.
Conference Presentation
© (2019) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Qihui Lyu, Dan Ruan, John Hoffman, Ryan Neph, Michael McNitt-Gray, and Ke Sheng "Iterative reconstruction for low dose CT using Plug-and-Play alternating direction method of multipliers (ADMM) framework", Proc. SPIE 10949, Medical Imaging 2019: Image Processing, 1094906 (15 March 2019); https://doi.org/10.1117/12.2512484
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image processing

Computed tomography

Reconstruction algorithms

Denoising

Image resolution

Image restoration

Model-based design

Back to Top