Paper
27 March 2018 Numerical study of cornea applanation by using a portable force-displacement sensor for intraocular pressure measurements
Author Affiliations +
Abstract
Intraocular pressure (IOP) is considered as a critical sign for glaucoma diagnosis. Tonometry, such as Goldmann applanation tonometry, Tono-Pen and noncontact tonometry, are widely used in clinical practices for IOP evaluations. However, limitations of the tonometry, such as high cost, operating complexity, and lack of feasibility are major concerns in a busy clinic. In this paper, we propose a facile method for IOP monitoring by utilizing a simple constructed force/displacement-hybrid sensor. The device is constructed by a capacitive force sensor mounted on handheld linear stage, which is able to record the force and travel distance simultaneously. A numerical study based on the finite element method (FEM) is used to evaluate the performance of the sensor for the IOP detections. In particular, a numerical corneal-sensor model is built by the FEM, in which the sensor is placed on the apex of the corneal structure. As the sensor presses against the cornea, the physical parameters, such as the contact pressure, the contact area between the sensor and the cornea, the travel displacement of the sensor are recorded. Importantly, to improve the modeling accuracy, we use a dynamic Young’s modulus in the cornea model, considering the multi-layered structure of the human cornea whose Young’s modulus varies as the IOP changes. Our sensor exhibits a highly linear relationship between the contact pressure and the travel displacement in the progress of cornea applanation, from which the IOP can be simply derived. A minimal pressure of 1mmHg can be sensitively detected by our sensor, which is highly desired in clinical trials.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ting Yao, Baoqing Nie, and Xinjian Chen "Numerical study of cornea applanation by using a portable force-displacement sensor for intraocular pressure measurements", Proc. SPIE 10598, Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2018, 105983Q (27 March 2018); https://doi.org/10.1117/12.2296262
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Cornea

Finite element methods

3D modeling

Eye models

Thin films

Eye

RELATED CONTENT


Back to Top