Presentation + Paper
15 February 2018 Accuracy and precision in broadband laser ranging
Author Affiliations +
Abstract
Broadband laser ranging uses spectral interferometry and a dispersive Fourier transform to perform high repetition rate position measurements of explosively-driven surfaces typically moving at several km/s. A broadband fiber laser and fiber interferometer record distance as a relative delay between short pulses, and the beat spectrum of the pulses is mapped into the time domain via long propagation in dispersive fiber. Optical amplification and a fast oscilloscope allow the dispersed spectrum to be recorded in real-time, often at measurement rates of 20-40 MHz. The third-order phase of the dispersive fiber causes distortions in mapping the spectrum into time that must be compensated for when analyzing the measured data.

We characterize the accuracy and precision of BLR systems by performing a scan of static positions and comparing our single-shot measurements against position measurements from a commercial Michelson interferometer. We demonstrate a combination of hardware and data analysis that measures position to within 30 microns over a 27 cm range with very high precision.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Michelle Rhodes, Corey Bennett, and Daniel Perry "Accuracy and precision in broadband laser ranging", Proc. SPIE 10517, Real-time Measurements, Rogue Phenomena, and Single-Shot Applications III, 105170B (15 February 2018); https://doi.org/10.1117/12.2287420
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Ranging

Fiber lasers

Interferometers