Paper
15 October 1982 Monitoring Wafer Stepper Performance With Electrical Test Structures
M. A. Mitchell, V. Nagaswami
Author Affiliations +
Proceedings Volume 0342, Integrated Circuit Metrology I; (1982) https://doi.org/10.1117/12.933683
Event: 1982 Technical Symposium East, 1982, Arlington, United States
Abstract
Metal crossbridge electrical test structures have been used to characterize linewidth non-uniformities caused by lithographic systems and processing. Artifacts can complicate the interpretation of electrical linewidth results. Self-heating in crossbridges is an artifact which can cause errors of more than 15%. Self-heating increases as the linewidth decreases. A procedure for eliminating self-heating effects is discussed.
© (1982) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
M. A. Mitchell and V. Nagaswami "Monitoring Wafer Stepper Performance With Electrical Test Structures", Proc. SPIE 0342, Integrated Circuit Metrology I, (15 October 1982); https://doi.org/10.1117/12.933683