Paper
25 December 1979 Holographic Interferometry For Study On Hearing Mechanism And Combination With Optical Fibers
Tsuneyoshi Uyemura, Yoshio Ogura,, Yoshitaka Yamamoto, Shiro Shibata
Author Affiliations +
Abstract
Time-averaged holography is applied for vibration analysis of the tympanic membrane of frog, guinea-pig and human cadaver. Vibration. characteristics of human stapes which acts as a transmitter of vibration from tympanic membrane to internal ear were studied. Vibration of human skull by means of bone conduction. hearing and bone conduction hearing aid were analysed. Then, bone conduction. mechH.nism of skull with bone conduction hearing aid was investigated. Finally, possibility of holographic recording and holographic interferometry used with optical fiber system was studied theoretically,and it is verified with experiments.
© (1979) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Tsuneyoshi Uyemura, Yoshio Ogura,, Yoshitaka Yamamoto, and Shiro Shibata "Holographic Interferometry For Study On Hearing Mechanism And Combination With Optical Fibers", Proc. SPIE 0192, Interferometry, (25 December 1979); https://doi.org/10.1117/12.957859