6 March 2013 Comparison of the diagnostic accuracy of stationary digital breast tomosynthesis to digital mammography with respect to lesion characterization in breast tissue biopsy specimens: a preliminary study
Andrew W. Tucker, Yueh Z. Lee M.D., Cherie M. Kuzmiak M.D., Emily Gidcumb, Jianping Lu, Otto Zhou
Author Affiliations +
Proceedings Volume 8668, Medical Imaging 2013: Physics of Medical Imaging; 86685Q (2013) https://doi.org/10.1117/12.2008024
Event: SPIE Medical Imaging, 2013, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
Current practice for imaging surgical breast specimens is a single 2D magnification view on a mammography system, but 2D imaging overlaps the tissue in different planes causing distortion of lesion margins. Digital breast tomosynthesis (DBT) could be used as an alternative imaging modality for imaging breast specimens. DBT systems acquire multiple low dose projection images, over a small angular span, which are then reconstructed into a partial 3D volume. The reconstructed images can be used to increase visualization of lesion margins and extent of microcalcifications (MCs). Current commercial DBT systems use a single rotating X-ray source, the movement of which produces motion blur. Motion blur reduces visualization of small objects such as MCs. MCs, depending on size and structure, can be implicative of breast cancer. We have developed a stationary DBT (s-DBT) system using a linearly distributed, CNT Xray source array. S-DBT allows for rapid acquisition of projection images with no image degradation from X-ray source motion. Full tomosynthesis datasets can be acquired, allowing visualize of both masses and microcalcifications. Here we report the preliminary results of a reader study comparing breast specimen images from a 2D commercial mammography system and an s-DBT system. Preliminary results show that s-DBT is capable of producing equivalent image quality to 2D mammography, and in some cases is superior.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Andrew W. Tucker, Yueh Z. Lee M.D., Cherie M. Kuzmiak M.D., Emily Gidcumb, Jianping Lu, and Otto Zhou "Comparison of the diagnostic accuracy of stationary digital breast tomosynthesis to digital mammography with respect to lesion characterization in breast tissue biopsy specimens: a preliminary study", Proc. SPIE 8668, Medical Imaging 2013: Physics of Medical Imaging, 86685Q (6 March 2013); https://doi.org/10.1117/12.2008024
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Digital breast tomosynthesis

Imaging systems

Mammography

Breast

Tissues

Visualization

X-ray sources

Back to Top